• Title/Summary/Keyword: Pulse Analysis

Search Result 2,115, Processing Time 0.03 seconds

Coaxial Marx Type Pulse Generator for UWB EM Pulse (UWB 펄스전자파 발생용 원통형 Marx 펄스발생장치개발)

  • Chang, Yong-Moo;Lee, Sang-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.121-121
    • /
    • 2010
  • As the industrial technology is getting higher, the pulsed power technology is required from various fields such as thermonuclear fusion energy sources, military applications, electric power distribution, and a variety of new specialized needs. This technology deals with the generation of very high power electromagnetic pulses through fast switching. We fabricated a pulsed power generator, named EMD pulse generator, by using Marx circuit with 200 kV high, 50 ns fast rise time. In this paper, we described about an effect of stray capacitance of coaxial Marx generator, EPG-AM200k, and a comparing the results of experiments and circuit analysis.

  • PDF

The Shock-Test Result and Analysis Using Dual-Pulse Shock Testing Machine (이중충격파형 충격시험장비를 이용한 충격시험 결과 및 분석)

  • Bae, Jongsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.342-348
    • /
    • 2018
  • The important issue of equipment installed in maritime weapon system is shock survivability against underwater explosion(UNDEX). If the shock survivability of equipment should not be guaranteed, the successful mission also could not be achieved. For that reason, the shock-resistance of each equipment under UNDEX environment should be demonstrated before deployment at combat field. However, the actual UNDEX test on the ocean is too expensive to conduct. Also, it has diverse dangerous factors. The main characteristic of UNDEX is a dual-pulse shock. The vertical shock test machine able to simulate dual pulse shock signal on the ground will be introduced in this paper. The dual-pulse shock signal presented in certain shock standard was achieved with this shock-test machine on the ground. The analytical procedure to set a test condition was verified by comparing simulation result with experiment result.

Analysis of Both Hands' Two Pulse Waveforms using a Clip-type Pulsimeter Equipped with Magnetic Sensing Hall Device

  • Rhee, Jin-Kyu;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.183-187
    • /
    • 2013
  • Two concurrent signals of the pulse wave measured from both hands' radial artery in un-pressurization condition using the prototype model of two clip-type pulsimeters with a permanent magnet and Hall device are investigated. The phase differences of two pulse waves from 22 subjects have some distinct points according to the handedness. Thus, the propagation of the pulse wave calculated from phase difference is both fast and slow to each other. It is confirmed that this phenomenon comes from the difference of blood vessel hardness between right- and left-hand of each subject rather than a quantity of muscle.

Performance Assessment of SFM Pulse in Reverberation Environment

  • Shin Seung-Je;Lee Hyung-Soo;Bae Eun-Hyon;Park Do-Hyun;Lee Kyun-Kyung
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.254-257
    • /
    • 2004
  • In shallow water, the performance of the operating active sonar systems is usually limited by reverberation. One of the measure to overcome the negative effect of reverberation is of selecting an adequate transmission pulse. SFM(Sinusoidal Frequency Modulation) pulse has been received a considerable attention as a candidate for suppressing the reverberation effect. In this paper, we analyze the detection performance of SFM pulse with respect to modulation frequency and bandwidth. To conduct the analysis. we synthesize the signal at the receiver considering. the transmitter. the receiver, and the propagation medium characteristcs. The simulations provide the optimum modulation frequency and bandwidth under the given situation.

  • PDF

Analysis of the Wave Propagation Characteristic for Pulse Signal on Tapered Microstrip Line in Time Domain (테이퍼형 마이크로스트립 전송선로에서 펄스 신호의 시간 영역 전송특성 해석)

  • Kim Girae;Choi Young-Kvu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.1
    • /
    • pp.40-44
    • /
    • 2006
  • In this paper, the distortion characteristics of an electrical pulse which has a rise/fall time due to the dispersion and the reflection, on nonuniform tapered microstrip lines has investigated in time domain. The transmission characteristics on uniform microstrip lines in time domain had represented already, but the results for the nonuniform tapered microstrip lines not represented yet. We investigated the transmission characteristics for pulse signal on the nonuniform tapered microstrip lines, and the result applied to design of wide band impedance matching circuit in design of MMIC. The voltage and current transfer functions are shown for the tapered line. The dispersion and distortion obtained by using these transfer functions are represented for the nonideal square pulse.

Response Characteristic Analysis of ZnO Varistors by the Conductive E1 Pulse (전도성 E1 펄스에 대한 ZnO 바리스터의 동작특성 분석)

  • Bang, Jeong-Ju;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.3
    • /
    • pp.241-245
    • /
    • 2019
  • This work presents the response characteristics of a ZnO varistor to conductive EMP. An E1 pulse, standardized to MIL-STD-188-125-1, was applied to the varistors wherein the residual current and response times were measured with the applied E1 pulse current. Additionally, the response time was measured according to the length of the connection path. Consequently, the amplitude of the residual voltage through the ZnO varistors was increased with increasing amplitude of the applied E1 pulse current. As the length of the connection path increased, the operating response time and residual peak voltage also increased. These results indicate that the response characteristics of ZnO varistors can be applied to basic data to support the use of varistors as a protective measure against conductive EMP.

The Correlation of Pulse Wave Velocity and Atherosclerotic Risk Factor in Stroke Patients

  • Jin, Bok Hee;Han, Min Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.1
    • /
    • pp.28-34
    • /
    • 2015
  • Pulse wave velocity (PWV) is used to non-invasively estimate the severity of arteriosclerosis by measuring arterial stiffness. Increased arterial stiffness measured by PWV stands for progressive arteriosclerosis and is caused by atherosclerotic risk factors. This study is focused on how brachial-ankle pulse wave velocity (baPWV) is related to the leading risk factors for arteriosclerosis or atherosclerosis. Subjects were 114, 69 males and 45 females who are in 60's and had baPWV test for acute stroke. The results are as follows: the group with increased arterial stiffness showed significant increase in HbA1c, total cholesterol, BSBP (brachial artery systolic blood pressure), BDBP (brachial artery diastolic blood pressure), CSBP (central artery systolic blood pressure), CDBP (central artery diastolic blood pressure), augmentation index (AIx) and diabetes mellitus. Correlation analysis between baPWV and atherosclerotic risk factor showed significant relationship in age, HbA1c, LDL cholesterol, BSBP, BDBP, CSBP, CDBP and augmentation index. baPWV was independently related to age and BSBP in multiple linear regression analysis. The group with increased arterial stiffness was independently related to BDBP in multiple logistic regression analysis. This study might be meaningful in evaluating the relationship between arterial stiffness and atherosclerotic risk factor in a new way, and be helped to make various studies for cardiovascular disease.

Design and Construction of Integrated Database for Contents Development of Pulse Analysis System (맥진기 컨텐츠 개발을 위한 통합 데이터베이스 설계 및 구축)

  • So, Ji-Ho;Jeon, Young-Ju
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.137-142
    • /
    • 2017
  • The development of medical devices based on the theory of tranditional Korean medicine is increasing due to population aging and emerging demand for medical services. Various clinical trials are being conducted to ensure the clinical effectiveness of the developed medical devices, and the importance of systematic management of variously collected information in this process is increasing. In this paper, we designed and constructed the database that can systematically manage the medical information of the patient and the pulse measurement information in conducting clinical trials by using pulse analysis system which is a representative diagnostic method of traditional Korean medicine. The constructed database can be efficiently used for the verification of existing algorithms or developing new algorithms through the quality control of various information and measured data on clinical trials. It also has several advantages in the control of clinical data. The results of this study can contribute to the establishment of Korean medical device data standard for the construction of integrated database management system that can share information with different kind of pulse analysis system and other bio-signal measuring devices.

A study on The Pulse taking diagnostics of Nan Jing 1-23 Nan (난경(難經) 1-23난중(難中) 맥학조(脈學條)에 관한 연구(硏究))

  • Kim, Bup-Jin;Park, Won-Hwan
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.131-154
    • /
    • 2000
  • Nan Jing(Difficult Classic), as a catechism, describes in detail and deeply the ideas in Nei Jing(Huangdi's Internal Classic). The description of Nan Jing is focused on basic theories including theories about some disease and is excellent in identification and analysis. The contents of Nan Jing are as follows: 1-23 Nan-pulse and pulse condition, 24~29 Nan-channels and collaterals, 30~47 Nan-viscera and bowels(Zang Fu organs), 48~61 Nan-disease, 62~68 Nan-acupuncture points, 69~91 Nan-acupuncture. Especially, diagnosis techniques in Nan Jing make 'Only method of cunkou pulse taking' that is a technique for feeling the pulse widely applied in these days in Oriental medicine clear. Thus, this book adjusts the theory of pulse and pulse condition given in 1~23 Nan of 'The Study of Nan Jing' in order to enhance an understanding about the theory of pulse and pulse condition. The text of 1~23 Nan about pulse lore centers on all pulse of human body interconnected each other and cunkou, both ends of the pulse, and contrasts regular pulse with irregular pulse. 1. 10 Nan describes the theory about five kinds of evils and hardness and softness, and unique pulse condition of each bowels. 2. 13 Nan explains that the relative difficulty of medical treatment is determined by the degree of balance or unbalance among three factors-colors, pulse and pulse condition, flesh shape. 3. 14 Nan divides pulse and pulse condition into slow pulse and rapid pulse, and explains separately abnormality, great loss of semen, death caused by slow pulse, and abnormality, great loss of semen, death caused by rapid pulse. 4. 15 Nan about taut pulse(弦), full pulse(鉤), floating pulse(毛), deep pulse(石脈) describes that pulse and pulse condition differs according to four seasons. Therefore, Nan Jing establishes clearly techniques of feeling the pulse in 'Only method of cunkou pulse taking(獨取寸口)' and advances the theory of Nei Jing. Futhermore, Nan Jing is more valuable in that it suggests unique theory different with Nei Jing.

  • PDF

A Effect of Photo Dynamic Therapy for LAZER Wave Mode (방사모드에 따른 레이저 치료 효과)

  • Choi, Deog Su;Lim, Hyun Soo;Lee, Byung Koo;Kenar, Necla
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.134-139
    • /
    • 2016
  • US Food and Drug Administration (FDA) approved as a innovative cure for cancer, 1996. The effect is death of cancer cells through necrosis, apoptosis. Mainly the Continuous Wave mode (CW) use for PDT Laser. It sting, the question including itch, and etc. Reportedly, the increase of temperature with the perforated edema, ulcer, necrosis. The Thermal relaxation time and Oxygen recovery time is necessary. To give a normal oxygen recovery time of the cell, used Pulse mode. Progress, it was Burst Pulse mode when easing the thermal wake, the simplicity was secured, the PDT effect is good. Excepted in control group CW, Pulse, Burst pulse mode were incubated with various concentrations of 5-aminolevulinic acid hydrochloride (ALA-5). The tumor size reduction CW mode (44%), Pulse mode (48%), Burst pulse mode (53%) at 4 week after PDT with 0.3, 0.3, 0.3 mg/ml of ALA-5. After 4 hours, investigation of 100, 100, $100J/cm^2$ laser irradiation. The pulse mode was superior in expirimental data analysis. And it was the Burst pulse mode edge head of a family effect.