DOI QR코드

DOI QR Code

Analysis of Both Hands' Two Pulse Waveforms using a Clip-type Pulsimeter Equipped with Magnetic Sensing Hall Device

  • Rhee, Jin-Kyu (Optical Nano-Imaging Team, Korea Basic Science Institute) ;
  • Lee, Sang-Suk (Department of Oriental Biomedical Engineering, Sangji University)
  • Received : 2012.06.05
  • Accepted : 2012.07.19
  • Published : 2013.06.30

Abstract

Two concurrent signals of the pulse wave measured from both hands' radial artery in un-pressurization condition using the prototype model of two clip-type pulsimeters with a permanent magnet and Hall device are investigated. The phase differences of two pulse waves from 22 subjects have some distinct points according to the handedness. Thus, the propagation of the pulse wave calculated from phase difference is both fast and slow to each other. It is confirmed that this phenomenon comes from the difference of blood vessel hardness between right- and left-hand of each subject rather than a quantity of muscle.

Keywords

References

  1. M. F. P. O'Rourke, R. P. Kelly, and A. P. Avolio, "The Arterial Pulse", 1st Ed.; Lea & Febiger: Philadelphia, PA, USA, 1992.
  2. S. S. Lee, M. C. Ahn, and S. H. Ahn, J. Magnetics 14, 132 (2009). https://doi.org/10.4283/JMAG.2009.14.3.132
  3. S. D. Choi, S. W. Kim, G. W. Kim. M. C. Ahn, M. S. Kim, D. G. Hwang, and S. S. Lee, J. Magn. Magn. Mater. 310, e983 (2007). https://doi.org/10.1016/j.jmmm.2006.10.1027
  4. S. W. Kim, Y, G, Choi, H. S. Lee, D. H. Park, D. G. Hwang, S. S. Lee, G. W. Kim, S. G. Lee, and S. J. Lee, J. Appl. Phys. 99, R908 (2006).
  5. M. C. P. Carrasquero, L. M. H. Bemard, H. Kobori, Y. Ozawa, K. S. H. Smith, L. L. Hamm, and L. G. Navar, Hypertension 44, 223 (2004). https://doi.org/10.1161/01.HYP.0000135678.20725.54
  6. Q. Yu, J. Zhou, and Y. C. Fung, Am. J. Physiol. Heart Circ. Physiol. 265, 52 (1993).
  7. M. C. Ahn, J. G. Choi, I. H. Son, S. S. Lee, and K. H. Kim, J. Korean Magn. Soc. 20, 106 (2010). https://doi.org/10.4283/JKMS.2010.20.3.106
  8. S. S. Lee, D. H. Nam, Y. S. Hong, W. B. Lee, I. H. Son, K. H. Kim, and J. G. Choi, Sensors 11, 1784 (2011). https://doi.org/10.3390/s110201784
  9. S. S. Lee, I. H. Son, J. G. Choi, D. H. Nam, Y. S. Hong, and W. B. Lee, J. Korean Phys. Soc. 58, 349 (2011). https://doi.org/10.3938/jkps.58.349
  10. I. H. Son, K. H. Kim, J. G. Choi, D. H. Nam, and S. S. Lee, IEEE Trans. Magn. 47, 3063 (2011). https://doi.org/10.1109/TMAG.2011.2155044
  11. Min Soon, "Medical Terminology", 3rd Ed.; Chung-Ku Pulblishing Co., Korea, 2002.
  12. A. L. Kierzenhaum, "Histology and Cell Biology", Mosby, Inc. St. Louis, Missouri, USA, 2002.
  13. Sang Hong Baek, Pulse Wave Velocity, Clinical Vascular Medicine, Korean Vascular Research Working Group, 109-124 (2009).
  14. H. Y. Park, S. Y. Lee, S. W. Cho, S. U. Kwon, J. Namgung, J. H. Do, and W. R. Lee, Korean Circulation J. 36, 393 (2006). https://doi.org/10.4070/kcj.2006.36.5.393

Cited by

  1. Fuzzy Simulation of a Multi-electronic Acupuncture System and Clip-type Pulsimeter Equipped with a Magnetic Sensing Hall Device vol.19, pp.3, 2014, https://doi.org/10.4283/JMAG.2014.19.3.255
  2. Property of Wireless Clip-type Pulsimeter by Using a Hall Device and a Permanent Magnet vol.24, pp.6, 2014, https://doi.org/10.4283/JKMS.2014.24.6.179