• Title/Summary/Keyword: Pulling-out length

Search Result 15, Processing Time 0.021 seconds

Changes of Pulling-out Length and Shrinkage Ratio in Polyester/Spandex Power Net Warp Knitted Fabrics

  • Lee Choon-Gil
    • Fibers and Polymers
    • /
    • v.7 no.1
    • /
    • pp.51-56
    • /
    • 2006
  • Power net fabric is one of the highly extensible two-way fabrics. Power net structure shows special characteristics in the wearing of final functional clothes. This research evaluated effects of treatment temperature on proportional extensibility and shrinkage ratio of spandex at a given wale length. As treatment temperature increased, extensibility increased proportionally to the standard length of the sample and the shrinkage ratio in the direction of course and wale increased. The pulling-out length increased proportionally to the standard length of the sample. However it was affected by the effect of treatment time and temperature due to the thermal properties of spandex filament yarn.

A Case Study on Individually Controlled Pull-out Test for Ground Anchor (지반앵커의 인발시험을 위한 개별제어 긴장장치의 적용 사례 연구)

  • Shin, Hyeon-Cheol;Choi, Yong-Kyu
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.545-552
    • /
    • 2008
  • To insure the quality and safety of ground anchors, pull-out test of anchor has to be done. In the individually controlled pull-out test system, pull-out device is used to introduce the same pull-out force to individual tendon that has a different length and a deflection. That is, that device has a separate pull-out oil jack to each tendon, thus the pull-out length of each jack is not the same, but that device introduces each tendon to the same pull-out force. In this study, the in-situ pull-out tests for the compression anchors were performed and its test results were analysed and compared to the results of center hole pull-out tests. In the case of pulling out each tendon using the individually controlled pull-out test device, the pull-out forces were distributed to a individual tendon. That device is excellent one that can solve the cause of unequal pull-out forces of each tendon appearing in the manufacture process and construction of anchors, and unequal pull-out forces due to the deferent length.

  • PDF

Pulling-out Length of Spandex and Shrinkage Ratio of Fabric in the Polyester-spandex Power Net Warp Knitted Fabric (폴리에스터-스판덱스 파워 네트 원단의 스판덱스 인장길이와 수축률)

  • 이춘길
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10b
    • /
    • pp.289-290
    • /
    • 2003
  • 본 연구는 폴리에스터-나일론 파워 네트 원단의 건열특성을 다룬 것이다. 이 건열특성은 스판덱스(spandex)의 특성에 크게 영향을 받는다. 스판덱스는 통상 활용할 수 있는 신도가 500~600 %에 이른다는 성질 때문에 섬유제품에 많이 응용되고 있다 이는 탄성이 양호하여 스타킹용, 수영복용 등으로 많이 활용하고 있다. 또한 스판덱스는 마모와 마찰강도가 고무보다 우수하고 탄성이 아주 좋고 리 쓰인다. (중략)

  • PDF

Minimal-incision tenorrhaphy in flexor tendon injury (굴곡건 손상에서 최소절개 건 봉합술)

  • Jang, Ju Yun;Oh, Sang Ah;Kang, Dong Hee;Lee, Chi Ho
    • Archives of Plastic Surgery
    • /
    • v.36 no.4
    • /
    • pp.516-518
    • /
    • 2009
  • Purpose: To retrieve the retracted flexor tendon, additional incision and wide dissection are conventionally required. We introduce minimal - incision tenorrhaphy using 1 cm - length incision and minimal dissection. Methods: Transverse incision about 1 cm - length is made over the level of retracted tendon. Nelaton's catheter is advanced into tendon sheath from distal primary laceration wound to emerge proximally through the incisional wound. Catheter is sutured to proximal tendon in end - to - end fashion. By gently pulling the catheter, retracted tendon is delivered to distal wound. Tenorrhaphy with core suture and epitendinous suture is then carried out. Results: This retrieving technique provides minimal incision, minimal dissection, minimal bleeding, minimal injury to tendon end, and shorter operation time with preservation of vincula tendinum and pulley system. Conclusion: In case of flexor tendon rupture with retraction, this operative method is believed to allow reliable and effective tenorrhaphy and excellent postoperative outcomes.

Experimental investigation of the pullout behavior of fiber concrete with inclination steel fibers

  • Seyyed Amir Hossein, Madani;S. Mohammad, Mirhosseini;Ehsanolah, Zeighami;Alireza, NezamAbadi
    • Advances in concrete construction
    • /
    • v.14 no.5
    • /
    • pp.299-307
    • /
    • 2022
  • Cement-based matrixes have low tensile strength and negligible ductility. Adding fibres to these matrixes will improve their mechanical properties and make these composites suitable for structural applications. Post-cracking tensile strength of steel fibers-reinforced cementitious composite materials is directly related to the number of transverse fibers passing through the crack width and the pulling-out behavior of each of the fibers. Therefore, the exact recognition of the pullout behavior of single fibers is necessary to understand the uniaxial tensile and bending behavior of steel fiber-reinforced concrete. In this paper, an experimental study has been carried out on the pullout behavior of 3D (steel fibers with totally two hooks at both ends), 4D (steel fibers with a total of four hooks at both ends), and 5D (steel fibers with totally six hooks at both ends) in which the fibers have been located either perpendicular to the crack width or in an inclined manner. The pullout behavior of the mentioned steel fibers at an inclination angle of 0, 15, 30, 45, and 60 degrees and with embedded lengths of 10, 15, 20, 25, and 30 millimetres is studied in order to explore the simultaneous effect of the inclination angle of the fibers relative to the alongside loading and the embedded length of fibers on the pullout response in each case, including the maximal pullout force, the slip of the maximum point of pullout force, pullout energy, fiber rupture, and concrete matrix spalling. The results showed that the maximum pullout energy in 3D, 4D, and 5D steel fibers with different embedded lengths occurs at 0 to 30° inclination angles. In 5D fibers, maximum pullout energy occurs at a 30° angle with a 25 mm embedded length.

A Study on the Pullout Behavior of Shear Connectors which Fix the Additional Wall to the PHC-W Piles in the PHC-W Type Permanent Building Retaining Wall (PHC-W 흙막이를 활용한 건축영구벽체에서 PHC-W말뚝과 증설벽체를 합벽시키는 전단연결재의 인발거동에 관한 연구)

  • Jin, Hong-min;Kim, Sung-su;Choi, jeong-pyo;Choi, Yongkyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.12
    • /
    • pp.107-113
    • /
    • 2017
  • Shear Connector should be used to fix the PHC pile with extension wall in order to utilize PHC-W retaining wall as permanent wall. The pullout behaviours on shear connectors anchored into PHC-W pile were observed as two modes. The first type behaviour showed that after reaching the maximum pullout resistance, the anchorage was broken and shear connector was pulled out abruptly. The second type behaviour showed that even after arriving the maximum pullout resistance, the anchorage was not destroyed and there was a progressive increase in pullout displacement. The maximum pullout resistance of the steel anchor shear connector is larger than that of deformed bar shear connector. The larger the diameter and the longer the embedment length of shear connector, the higher the maximum pullout resistance would be. The pullout displacements corresponding to the maximum pullout resistance of the shear connector showed various ranges regardless of the materials, the diameters and the anchoring lengths. A-D20 shear connectors showed a pull-out displacement of about 8~10 mm. A-D16, D-D19 and D-D16 shear connectors exhibited a pulling displacement of about 14~20 mm, but a pulling displacement of about 6~10 mm when the anchoring lengths were 50 and 80 mm.

A Study on the Clothing Inconvenience Levels for the Clothing Improvement of Female Arthritis Patients (여성관절염질환자의 의복개선을 위한 의복불편정도에 관한 연구)

  • Han, Seung-Hee
    • Journal of Fashion Business
    • /
    • v.12 no.5
    • /
    • pp.111-125
    • /
    • 2008
  • The purpose of this study is in the investigation to relieve into the clothing inconvenience levels and to need by arthritis patients who experience clothing difficulties in daily living even without showing conspicuous physical disabilities. For this study, personal interviews were carried out with 151 female arthritis patients, using a questionnaire form consisting of a total of 206 items. Data analysis were done with spss 12.0 for the frequency analysis, cross tab analysis, t-test, and ANOVA. The findings are as follows. 1. The survey subjects were diverse in their age from 20s to 60s and 18.5% of them have need of other's assistance at the time of getting dressed or undressed of clothing. The knee part was felt to be the most uncomfortable, causing the inconveniences in wearing pants or panties. 2. The investigation into the inconvenience levels at the time of dressing or undressing of clothing was indicated that the wearing of pants was the hardest movement to arthritis patients, as the items relating to the movements for putting feet into or pulling them out of pants and those for raising pants over the hip were also accompanied by the feeling of pains. In addition, the aged arthritis patients felt the clothes-wearing movements more difficult. 3. The survey on the kind and inconvenience levels for the clothes currently being worn showed the highest wearing ratio for the pants, which were pointed out to be the most inconvenient. 4. As for the clothing improvement, the needs were located as a whole in the sufficiency in measures of pants crotch and circumference items, the flexibility in materials, the short length of pants, or the front clearance.

Pull-out Resistance Behavior of the Anchor with the Bump Type Resistors (돌기형 저항체를 설치한 앵커의 인발저항거동)

  • You, Min-Ku;Lee, Sang-Duk
    • Journal of the Korean Geotechnical Society
    • /
    • v.33 no.11
    • /
    • pp.35-43
    • /
    • 2017
  • In this study, the pull-out resistance behavior of the anchor with the bump type resistors at the anchor body was experimentally investigated. In the model tests, the pull-out resistance was measured by pulling out the anchor at a constant speed. Anchor body was installed in the center of the circular sand tank. Pull-out tests were conducted for 10 conditions. The anchor type (existence of the resistor), the friction conditions of the anchor body surface ($1/3{\phi}$, $2/3{\phi}$, ${\phi}$), the bump type resistor set number (1set, 2set, 4set), and the height of resistors (0.05d, 0.10d, 0.20d) were varied. The load-displacement relationship for each conditions was measured during the pull-out tests at a constant speed (1 mm/min). Maximum pull-out length was 80 mm. As a result, the pull-out behavior of the friction type anchor and the expansion type anchor was different. As the number of resistor increased, the maximum pull-out resistance increased and the residual pull-out resistance ratio increased significantly, which were at 171~591 percent larger than that of the friction type anchor.

The Model Experiment on Holding Power of the Anchors used in the Set Net (정치망 고정용 닻의 파주력에 대한 모형실험)

  • 윤일부;이주희;권병국;김성훈;신정욱
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.95-105
    • /
    • 2001
  • A series of experiment is carried out to determine the holding power of the existing anchors used in the stationary gear in the coast of the South sea. The experiment apparatus is made of the pulling machine, the load cell, the personal computer and three water tanks the bottom of which are mud, sand and m & s respectively. The result obtained are as follows : 1. On the tension and holding power of the existing anchors, B-type of the stock anchor with two fluke shows the greatest and gets smaller on order of A-type one with a fluke. The holding power of the anchors shows the greatest in the mud and gets smaller in order of m & s, sand. And, the holding power depending upon the length of anchor rope increase as the length does up to the 4 times of depth. 2. On the holding power per fluke area of the existing anchors in case of ration of length of anchor rope to depth is 2, 3 and 4, A-type anchor shows about 310-320 kg/m supper(2), 470-480 kg/m supper(2), 590-640 kg/m supper(2) respectively, B-type one 260-265 kg/m supper(2), 390-450 kg/m supper(2), 630-700 kg/m supper(2) respectively, and C-type one 70-100 kg/m supper(2), 150-180 kg/m supper(2), 210-270 kg/m supper(2) respectively. The holding power per fluke area of the anchors increase as the length of anchor rope does. 3. On the coefficient of holding power of the existing anchors, A-type anchor shows the greatest and gets smaller in the order of B-type one, C-type one.

  • PDF

Comparison of New Hanbok Jeogory Pattern for Customizing System Development

  • Cha, Su-Joung;Heo, Seung-Yeun;An, Myung-Sook
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.11
    • /
    • pp.167-178
    • /
    • 2020
  • This study attempted to find out the difference in the patterns of jeogori between commercially available Shinhanbok brands by comparing and analyzing the patterns of the changing Shinhanbok jeogori in consideration of material characteristics, fit, and fastening. After purchasing and disassembling 6 products, analysis was conducted with the disassembly pattern. As a result of analyzing the shape of the jeogori, the 1st, 3rd and 6th brands showed no darts. In the case of the 5th brand, the three-dimensional effect of the human body was expressed with a princess line. As a result of the appearance evaluation, the 5 brands were evaluated as the highest in most items except for the space of the front width and the group wrinkles of back sleeve armhole, and the appearance was analyzed to be the best. As a result of evaluating the clothing pressure, it was analyzed that the chest circumference of the first brand was smaller than that of the other brands, and the shoulder width and shoulder length were also shorter, and pulling occurred even after wearing. As the demand for new hanbok increases, it is believed that it is necessary to establish a size system for ready-made clothes.