Browse > Article
http://dx.doi.org/10.7843/kgs.2017.33.12.107

A Study on the Pullout Behavior of Shear Connectors which Fix the Additional Wall to the PHC-W Piles in the PHC-W Type Permanent Building Retaining Wall  

Jin, Hong-min (Musung Construction Co., Ltd.)
Kim, Sung-su (Musung Construction Co., Ltd.)
Choi, jeong-pyo (Musung Construction Co., Ltd.)
Choi, Yongkyu (School of Civil, Environmental & Urban Engrg. Kyungsung Univ.)
Publication Information
Journal of the Korean Geotechnical Society / v.33, no.12, 2017 , pp. 107-113 More about this Journal
Abstract
Shear Connector should be used to fix the PHC pile with extension wall in order to utilize PHC-W retaining wall as permanent wall. The pullout behaviours on shear connectors anchored into PHC-W pile were observed as two modes. The first type behaviour showed that after reaching the maximum pullout resistance, the anchorage was broken and shear connector was pulled out abruptly. The second type behaviour showed that even after arriving the maximum pullout resistance, the anchorage was not destroyed and there was a progressive increase in pullout displacement. The maximum pullout resistance of the steel anchor shear connector is larger than that of deformed bar shear connector. The larger the diameter and the longer the embedment length of shear connector, the higher the maximum pullout resistance would be. The pullout displacements corresponding to the maximum pullout resistance of the shear connector showed various ranges regardless of the materials, the diameters and the anchoring lengths. A-D20 shear connectors showed a pull-out displacement of about 8~10 mm. A-D16, D-D19 and D-D16 shear connectors exhibited a pulling displacement of about 14~20 mm, but a pulling displacement of about 6~10 mm when the anchoring lengths were 50 and 80 mm.
Keywords
The PHC-W retaining wall method; The PHC-W type permanent building retaining wall; PHC-W pile; Pullout test; Steel anchor; Deformed bar; Shear connector; Maximum pullout force;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Byun, D. K., Sin, H. M., and Moon, J. G. (2002), Reinforced Concrete, Vol.6, Dongmyung, Korea, p.33.
2 Choi, J. P. (2014), Study on the Economic Analysis of Retaining PHC-W Method Improved High Strength Pile, Master's Thesis, Busan National University, pp.25-33.
3 Hill Engineering Structral Technology Co. (2017), Construction project report of Rainwater Storage Tank at 844-9, Daedond-ro, Daedong-myeon, Gimhae-city, pp.1-249.