• Title/Summary/Keyword: Pull-in voltage

Search Result 132, Processing Time 0.028 seconds

Measurement and Control of the Resonance Frequency for the Transcutaneous Energy Transmission System (TET) Using the Phase Locked Loop Circuit (PLL) (PLL을 이용한 무선 전력전송 장치의 공진 주파수의 계측 및 주파수 제어)

  • Choi, S.W.;Shim, E.B.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1613-1616
    • /
    • 2008
  • A Transcutaneous Energy Transmission System (TET) has been developed for the wireless energy transmission with two magnetically coupled coils. A resonance circuit is used to raise the induced voltage and current of the secondary coil. Its resonance frequency depends on the internal resistance of circuit and the transferred energy. Because the transferred energy usually changes in wide range, the output voltage is unstable and the energy transferring efficiency decrease. A push-pull class E amplifier is usedto generate high frequency AC voltage. To maintain proper resonance frequency, the voltage output of the amplifier was continuously monitored and adjusted to the optimized resonance frequency. Because of its high frequency (370 kHz), a phase lockedloop circuit and a comparator are used to monitor the output waveform. The results of experimentaldata show that the PLL circuit can increase the transmission efficiency and stabilize the output voltage of TET.

  • PDF

Integrated Gate Driver Circuit Using a-Si TFT with AC-Driven Dual Pull-down Structure

  • Jang, Yong-Ho;Yoon, Soo-Young;Kim, Binn;Chun, Min-Doo;Cho, Hyung-Nyuck;Cho, Nam-Wook;Sohn, Choong-Yong;Jo, Sung-Hak;Choi, Seung-Chan;Kim, Chang-Dong;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.944-947
    • /
    • 2005
  • Highly stable gate driver circuit using a-Si TFT has been developed. The circuit has dual-pull down structure, in which bias stress to the TFTs is relieved by alternating applied voltage. The circuit has been successfully integrated in 4-in. QVGA and 14-in. XGA TFT-LCD with a normal a-Si process, which are stable for over 2,000 hours at $60^{\circ}C$. The enhancement of stability of the circuit is attributed to retarded degradation of pull-down TFTs by AC driving.

  • PDF

Design of an eFuse OTP Memory of 8bits Based on a Generic Process ($0.18{\mu}m$ Generic 공정 기반의 8비트 eFuse OTP Memory 설계)

  • Jang, Ji-Hye;Kim, Kwang-Il;Jeon, Hwang-Gon;Ha, Pan-Bong;Kim, Young-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.687-691
    • /
    • 2011
  • In this paper, we design an 8-bit eSuse OTP (one-time programmable) memory in consideration of EM (electro-migration) and eFuse resistance variation based on a $0.18{\mu}m$ generic process, which is used for an analog trimming application. First, we use an external program voltage to increase the program power applied an eFuse. Secondly, we apply a scheme of precharging BL to VSS prior to RWL (read word line) activation and optimize read NMOS transistors to reduce the read current flowing through a non-programmed cell. Thirdly, we design a sensing margin test circuit with a variable pull-up load out of consideration for the eFuse resistance variation of a programmed eFuse. Finally, we increase program yield of eFuse OTP memory by splitting the length of an eFuse link.

  • PDF

A Single-Stage AC-DC Power Module Converter for Fast-Charger (급속충전기용 파워 모듈을 위한 단일단 AC-DC 컨버터)

  • LE, Tat-Thang;Choi, Sewan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.5
    • /
    • pp.384-390
    • /
    • 2022
  • In this study, a single-stage, four-phase, interleaved, totem-pole AC-DC converter is proposed for a super-fast charger station that requires high power, a wide voltage range, and bidirectional operation capabilities and adopts various types of electric transport vehicles. The proposed topology is based on current-fed push-pull dual active bridge converter combined with the totem-pole operation. Owing to the four-phase interleaving effect, the bridge on the grid side can switch at 0.25, 0.5, and 0.75 to achieve a ripple-free grid current. The input filter can be removed theoretically. Switching methods for the duty of the secondary-side duty cycle are proposed, and they correspond to the primary duty cycle for reducing the circulating power and handling the total harmonic distortion. Therefore, the converter can operate under a wide voltage range. Experimental results from a 7.5 kW prototype are used to validate the proposed concept.

A Study On Synchronous Rectification Of Push-Pull Converter For Efficiency Improvement (효율개선을 위한 Push-Pull Converter의 동기정류에 관한 연구)

  • Kim D.J.;Kim Y.G.;Kim L.H;Won C.Y.;Kim G.S.;Choi S.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.345-351
    • /
    • 2003
  • Single winding self driven synchronous rectification(SWSDSR) scheme is based on an additional winding in the power transformer (auxiliary winding). It allows for maintaining the synchronous rectifiers on even when the voltage in the transformer is zero, which is impossible to do in traditional self-driven approaches. Its technique is verified to improve the efficiency by experiment. In this paper, there are compared self driven synchronous rectification(SDSR) with SWSDSR about the efficiency

  • PDF

Pull-out Test of Pulse Powered Underreamed Anchors (펄스방전 확공형 앵커의 현장시험)

  • Kim, Nak-Kyung;Ju, Yonh-Sun;Kim, Sung-Kyu;Seo, Hyo-Kyun;Kim, Tae-Hun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1014-1021
    • /
    • 2008
  • Ground anchor should not be used in soft clay, because anchor resistance can not be guaranteed. However, there is a way to increase the capacity of anchors. The pulse powered anchor is an underreamed anchor by using high voltage electrokinetic pulse energy. In this paper, conceptual introduction of the pulse powered anchor was presented. Anchor pull-out tests were performed at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea. Data were analyzed in order to verify the performance of pulse powered anchors.

  • PDF

A Noval High Efficiency Grid Connected 1kW PCS for Fuel Cell (새로운 고효율 계통연계 1kW 연료전지용 PCS)

  • Kim, Tae-Jin
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.5
    • /
    • pp.417-422
    • /
    • 2008
  • In this paper, a novel DC/DC low-voltage high-current converter circuit is proposed to improve the efficiency of power converter used in the grid-connected fuel-cell generator system. We proposed a novel high efficiency grid-connected power conditioning system for RPG fuel cell. On the result of that, the loss of system was decreased rapidly by driving stack within the condition of maximum efficiency. The peak currents of the current-type inductor and the transformer's coil are reduced by synchronizing switching frequency of Buck-type converter is increased twice as the Push-Pull converter's switching frequency. The novel structure of DC/DC converter is able to realize ZVS-ZCS in fuel-cell system is proposed. The proposed switching component of Push-Pull converter has the ZVS and ZCS function by using the circuit of new passive clamp.

A Bidirectional Three-phase Push-pull Zero-Voltage Switching DC-DC Converter (양방향 3상 푸쉬풀 ZVS DC-DC 컨버터)

  • Kwon, Min-Ho;Han, Kook-In;Park, Jung-Sung;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.403-411
    • /
    • 2013
  • This paper proposes an isolated bidirectional three-phase push-pull dc-dc converter for high power application such as eco-friendly vehicles, renewable energy systems, energy storage systems, and solid-state transformers. The proposed converter achieves ZVS turn-on of all switches and volume of passive components is small by an effect of three-phase interleaving. The proposed converter has identical switching pattern for both boost and buck mode, and therefore can provide seamless characteristic at the mode transition. A 3kW prototype of the proposed converter has been built and tested to verify the validity of the proposed operation.

Effect of Hot Carrier Stress on The Power Performance Degradation in SOI MOSFET (Hot Carrier Stress로 인한 SOI MOSFET의 전력 성능 저하)

  • Lee, Byung-Jin;Park, Sung-Wook;Park, Jong-Kwan
    • 전자공학회논문지 IE
    • /
    • v.45 no.4
    • /
    • pp.7-10
    • /
    • 2008
  • In this work investigates hot carrier stress on the RF power of SOI MOSFET using load-pull measurement. We found that the RF power characteristics are affected by the hot carrier stress, and the DC performance of SOI MOSFET is clearly degraded after hot carrier stress at constant voltage measurement. And these experimental observations can be explained by the change of DC performance degradation coefficient under hot carrier stress.