• Title/Summary/Keyword: Public Water System

Search Result 453, Processing Time 0.039 seconds

Water Quality Management of Simple Piped Water Supply System and Its Satisfaction of the Residents (簡易上水道의 水質管理實態와 給水利用住民의 滿足度)

  • Chae, Han-Uk;Park, Jae-Yong;Moon, Hyo-Jung
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.13-22
    • /
    • 1999
  • For the purpose of inquiring into the actual conditions of water quality management of Simple Piped Water Supply(SPWS) and the satisfaction and attitudes of inhabitants about utilizing water-supply, this research was done through the questionnaires, the investigation of surrounding environment and water quality analysis in the Sangju city, Kyungsang-pookdo during 4 months from March to June, 1998. The fountainhead of SPES using ground water accounted for 65.3%, which was the highest rate in the group. Most of them was at least 10 years in the number of utilization year. 79.6% of them were exposed to many sorts of surrounding pollution origins. The examination of water was performed only through a test about water purification and 24.5% of them disinfection by chlorine also no residual chlorine was detected at all. All the waterworks did not have any education to the managers of water quality and 81.5% of them held physical examination. As a result of the water examination about SPWS, 65.3% of them were found incongruity and the valley and springing water accounted for higher than the underground water in the rate of incongruity. Looking into the details of the result in the water examination, a category of colon bacilli was ranked in the highest rate and the next one was general bacilli, nitric acid nitrogen and turbidity in order. In the satisfaction degree of the water quality, the satisfied accounted for 44.6%, and 29.2% each. Over the state of satisfaction about the ways of water examination, satisfaction accounted for 44.6%, and unsatisfaction 28.3%. Summarizing the result of the above-stated, the state of Water Quality Management of the SPWS was in a poor condition. Thus for the water Quality Management, systematic and scientific water Quality Management mainly by the administrative organization other than voluntary management by the village should be done beyond doubt. Additionally the opinions and demands of inhabitants utilizing the water supply have to be positively reflected in the affairs of water Quality Management so that the distrust of inhabitants to the SPWS should be settled.

  • PDF

Application of HACCP principles to MAR-based drinking water supply system (MAR기반 음용수 공급 시스템에의 HACCP 원리 적용)

  • Ji, Hyon Wook;Lee, Sang-Il
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.5
    • /
    • pp.533-543
    • /
    • 2016
  • Supplying clean and safe water to people is facing both quantitative and qualitative challenges. Due to climate change, access to freshwater becomes increasingly difficult, while pollution from various sources decreases the public trust in water quality. Managed aquifer recharge (MAR) which stores and uses surface water in aquifer is receiving attention as a new technology to secure freshwater. Recently, there is a global expansion in the attempt to combine general purification plants and hazard analysis and critical control point (HACCP) which manages all the process from raw material to consumer for food safety. This research is about an attempt to apply HACCP to the drinking water supply process using MAR to secure both quantity and quality of drinking water. The study site is a MAR plant being constructed in the downstream area of the Nakdong River Basin, South Korea. The incorporation of HACCP with MAR-based water supply system is expected to enhance the safety and reliability of drinking water.

Assessment of Documentation Status of the Statement on the Sea Area Utilization according to Artificial Structure Installation in Public Water (공유수면 인공구조물 설치에 따른 해역이용협의서 작성실태 평가)

  • Eom, Ki-Hyuk;Lee, Dae-In;Kim, Gui-Young;Yoon, Sung-Soon
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.3
    • /
    • pp.265-276
    • /
    • 2013
  • This study assessed documentation status of each environmental assessment items by analyzing the 243 case of marine EIS on the Consultation System of Sea Area Utilization. Observed rate of tidal elevation, current, temperature, salinity in maine environment were below 20%. The EFDC tool is applied substantially in hydrodynamic modeling. The verification process, however, is very insufficient using the recent observed data. Also, in-situ assessment rate of pelagic organism such as phytoplankton was below 50%, and assessment for Chlorophyll a was not accomplished. Ecological index evaluation for zooplankton and benthic ecosystem were not considered in statements. Especially, the rational assessment on the fisheries resources and protected species were very limited. It was necessary that the core assessment items (checklists) were established for environmental scoping. Furthermore, suggestion of information related to development, regional coastal management plan, aquaculture farms, and facilities were enhanced. The redundancy problem of proceedings between Environmental Impact Assessment and Sea Area Utilization Assessment System was improved.

A Study on Fire Extinguishing Performance of Closed Type Water Mist Nozzles for Ship's Accommodation (선박 거주구역의 방호를 위한 폐쇄형 미분무 노즐의 화재진압성능평가 연구)

  • Kwark, Ji-Hyun;Kim, Young-Han
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.1-9
    • /
    • 2012
  • Since accommodation, public space and service areas where people stay for all day occupy about 70% of a huge cruise ship, they have to be protected from the fire. International Maritime Organization has resolved that a water mist system should be equipped in this cruise ship according to SOLAS II-2 Reg. 10.6 and FSS code Ch. 7. The water mist system consists of mist nozzles, pressure vessels, section valves and pump unit etc. In particular, the water mist nozzles should be recognized by fire tests in accordance with IMO Res. MSC 265(84). In this study, the fire tests for cabin, corridor, public space and storage area have been conducted to develop the water mist nozzles appropriate to the regulation. Totally 5 types of nozzles were developed and have satisfied the whole performance requirements.

심부지하수 수질 보호를 위한 천부포획정 공법

  • 김강주;박성민;염병우
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.511-514
    • /
    • 2003
  • Nowadays, wells tapping the deep aquifers become general because water quality of the shallow groundwater has been gradually degraded over the last 30 years as a result of rapid industrialization and intensive agricultural activities. However, many of the deep wells also suffer problems of water-quality degradation in several years after the well installation, nevertheless those were properly completed and managed. It is believed that the heavy pumping from deep wells causes the doward movement of the contaminated, shallow groundwaters and introduces them into the deep aquifers. In this study, we introduces a shallow capture well system, which could effectively prevent the shallow groundwaters of poor water duality from moving into the deep aquifers by pumping of deep production wells. Even though additional costs are required to apply this system, we believe that this method could be appropriate for the deep wells that are important for the public health.

  • PDF

A Water Tap Equipped with a Sterlization/Purification System of Non-contact UV-lamp (비접촉식 자외선램프를 이용한 살균/정화 수도꼭지)

  • Min, Kyoung-Won;Won, Jong-Heon;Lee, Hyun-Cheol;Han, Dong-Youl
    • Journal of Industrial Technology
    • /
    • v.27 no.B
    • /
    • pp.3-7
    • /
    • 2007
  • Ultraviolet light(UV-C, wavelength: 200~280nm) is employed profitably for sterilizing drinking water. For most water serving apparatus such as a water purifier, a water cooler and heater, a coffee vending machine and etc., pre-sterilized water may be contaminated secondarily with bacillary inhabitation in a container before serving. In consideration of this problem, a household water tap which is equipped with a sterilization/Purification device in combination with non-contact UV-lamp, was designed to sterilize and purify water at the last outlet just before serving. Hopefully this simple but creative item may be commercialized for household and public use.

  • PDF

A review on recent advances in water and wastewater treatment facilities management for earthquake disaster response (지진발생 대응을 위한 상하수도시설 관리 및 기술 현황에 대한 고찰)

  • Park, Jungsu;Choi, June-Seok;Kim, Keugtae;Yoon, Younghan;Park, Jae-Hyeoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.34 no.1
    • /
    • pp.9-21
    • /
    • 2020
  • The proper operation and safety management of water and wastewater treatment systems are essential for providing stable water service to the public. However, various natural disasters including floods, large storms, volcano eruptions and earthquakes threaten public water services by causing serious damage to water and wastewater treatment plants and pipeline systems. Korea is known as a country that is relatively safe from earthquakes, but the recent increase in the frequency of earthquakes has increased the need for a proper earthquake management system. Interest in research and the establishment of legal regulations has increased, especially since the large earthquake in Gyeongju in 2016. Currently, earthquakes in Korea are managed by legal regulations and guidelines integrated with other disasters such as floods and large storms. The legal system has long been controlled and relatively well managed, but technical research has made limited progress since it was considered in the past that Korea is safe from earthquake damage. Various technologies, including seismic design and earthquake forecasting, are required to minimize possible damages from earthquakes, so proper research is essential. This paper reviews the current state of technology development and legal management systems to prevent damages and restore water and wastewater treatment systems after earthquakes in Korea and other countries. High technologies such as unmanned aerial vehicles, wireless networks and real-time monitoring systems are already being applied to water and wastewater treatment processes, and to further establish the optimal system for earthquake response in water and wastewater treatment facilities, continuous research in connection with the Fourth Industrial Revolution, including information and communications technologies, is essential.

A study on health risk assessment for small-scale water works in Gyeongnam province from 2014 to 2016 (2014~2016년 동안 경남지역 소규모 급수시설에 대한 건강 위해성 평가 연구)

  • Park, Ju-Won;Son, Song-Ee;Lee, Hu-Jang
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.227-237
    • /
    • 2018
  • Objectives: This study was investigated the characteristics of small-scale water works (SWW) in Gyeongnam area and conduct a health risk assessment of water-quality inspection items unfitted for water-quality standards (WQS). Methods: The characteristics of SWW in Gyeongnam province were analyzed using the data of SWW in the last three years (2014~2016) published in National Waterworks Information System. In addition, the health risk assessment for inspection items unfitted for WQS was carried out in four steps: hazard identification, dose-response assessment, exposure assessment, and risk characterization. Results: The total number of SWW in Gyeongnam area was gradually decreased from 2014 to 2016. In addition, drinking water sources of SWW were in the order of ground water, valley water, spring water, surface water, and river-bed water. The number of points unfitted for WQS in SWW by year was 22, 45, and 18 in 2014, 2015, and 2016, respectively, and a total of 112 points were found to unfit for WQS in SWW during 2014~2016. The hazard quotient (HQ) for fluoride, nitrate nitrogen, boron in the unfitted points for WQS was more than 1.0, and the mean values for turbidity and color in points unfitted for WQS were 2.38 nephelometric turbidity unit and 16.25 color unit, respectively. Conclusions: The HQ for fluorine, nitrate nitrogen and boron was more than 1.0 in points unfitted for WQS among SWW in Gyeongnam area, and the turbidity and the color degree exceeded WQS, which mean that there is a possibility of harmful impacts on the human health.

A network approach to local water management for building collaborative water governance: the case of Jeju special self-governing province (지방자치단체의 협력적 물 거버넌스 구축을 위한 네트워크 분석: 제주특별자치도의 물관리 사례를 중심으로)

  • Kim, Boram;Yang, Wonseok;Ahn, Jongho
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.9
    • /
    • pp.671-680
    • /
    • 2020
  • This study aims to explore structural properties and central actors of the local water policy system through a network approach, and to suggest practical implications for establishing collaborative water governance at the local level. Especially, this study conducts a social network analysis to empirically analyze the actors' roles and relationships of water management in Jeju Special Self-Governing Province and represent them with sociograms. In this study, the local water management network is divided into two dimensions: official work network, public-private policy network based on information-sharing and consultation. Also, the networks are divided into a whole network and two sectoral networks(water-use/water-quality). This study found some meaningful differences of structural properties and central actors not only in the official work networks and the policy networks but also in the water-use networks and the water-quality networks. Thus, public managers should diagnose and manage the relational properties among multiple stakeholders in local water sector through a network perspective. In particular, (1)co-operation between the administrative departments responsible for water-use and water-quality, and (2)information-sharing and consultation among public and private stakeholders should be improved to establish collaborative local water governance.

Major Watershed Characteristics Influencing Spatial Variability of Stream TP Concentration in the Nakdong River Basin (낙동강 유역에서 하천 TP 농도의 공간적 변동성에 영향을 미치는 주요 유역특성)

  • Seo, Jiyu;Won, Jeongeun;Choi, Jeonghyeon;Kim, Sangdan
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.3
    • /
    • pp.204-216
    • /
    • 2021
  • It is important to understand the factors influencing the temporal and spatial variability of water quality in order to establish an effective customized management strategy for contaminated aquatic ecosystems. In this study, the spatial diversity of the 5-year (2015 - 2019) average total phosphorus (TP) concentration observed in 40 Total Maximum Daily Loads unit-basins in the Nakdong River watershed was analyzed using 50 predictive variables of watershed characteristics, climate characteristics, land use characteristics, and soil characteristics. Cross-correlation analysis, a two-stage exhaustive search approach, and Bayesian inference were applied to identify predictors that best matched the time-averaged TP. The predictors that were finally identified included watershed altitude, precipitation in fall, precipitation in winter, residential area, public facilities area, paddy field, soil available phosphate, soil magnesium, soil available silicic acid, and soil potassium. Among them, it was found that the most influential factors for the spatial difference of TP were watershed altitude in watershed characteristics, public facilities area in land use characteristics, and soil available silicic acid in soil characteristics. This means that artificial factors have a great influence on the spatial variability of TP. It is expected that the proposed statistical modeling approach can be applied to the identification of major factors affecting the spatial variability of the temporal average state of various water quality parameters.