• Title/Summary/Keyword: Public Safety System

Search Result 1,131, Processing Time 0.027 seconds

Recent Trend of International Standards on the Safety Criteria for Electric Shock Protection (인체감전 안전기준에 관한 최근 국제규격의 동향)

  • Lee, Jong-Chul;Kim, Han-Soo;Lee, Ju-Chul;Kang, Sung-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.189-193
    • /
    • 2007
  • The grounding of an electrical system is one of the essential elements for public safety. Domestic practice of grounding system design has been to get grounding resistance values which are classified by facilities or equipment in the regulations. But the concept of grounding system design of IEC is, as a main factor of safety index, to consider touch voltage and step voltage instead of the resistance value itself. Recently IEC actively develops or revises safety related standards which are essential for the grounding system performance. In this paper, we present the recent trend of the international standards on the safety criteria for Electric Shock Protection.

  • PDF

Monitoring of Artificial Radionuclides in Edible Mushrooms in Korea (식용 버섯류에서의 인공 방사능 농도 조사)

  • Cho, Han-Gil;Kim, Ji-eun;Lee, Sung-nam;Moon, Su-kyong;Park, Yong-Bae;Yoon, Mi-Hye
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.6
    • /
    • pp.488-494
    • /
    • 2018
  • To ensure food-safety of mushrooms from radioactive contamination, edible mushroom samples distributed in Gyeonggi province in Korea were collected according to species and country of origin. A total of 284 mushrooms, belonging to 10 species (Lentinula edodes, Pleurotus ostreatus, Pleurotus eryngii, Agaricus bisporus, Flammulina velutipes, Phellinus linteus, Inonotus Obliquus (Chaga), Auricularia auricula-judae, Ganoderma lucidum and Tricholoma matsutake) were subjected to radioactivity testing. The concentration of artificial radionuclides, 131I, 134Cs, and 137Cs, was analyzed using gamma-ray spectrometry. 131I and 134Cs were not detected more than MDA value from all samples. Among 204 domestic mushrooms, however, 137Cs were detected in 0.21~2.58 Bq/kg from six cases (3 Lentinula edodes, 1 Ganoderma lucidum and 2 Tricholoma matsutake), whereas 137Cs were detected in 0.21~53.79 Bq/kg from 38 cases (22 Inonotus Obliquus(Chaga), 14 Phellinus linteus, 1 Lentinula edodes and 1 Tricholoma matsutake) among 80 imported mushrooms. In addition, average concentration of 137Cs in 10 Chaga mushroom-processed products was more than twice as much as dried Chaga mushroom, and maximum concentration was 123.79 Bq/kg. Results suggest that radioactivity monitoring system for imported mushrooms and mushroom-processed products should be continuously intensified to secure food-safety in Korea.

Innovation and Improvement of National Emergency Management System in Korea - Focused on All-Hazard Approach - (국가 재난관리 체계의 혁신과 발전방향: 모든 위험 접근법을 중심으로)

  • Kang, Uk;Park, Jun-Seok;Jo, Jun-Teak
    • Korean Security Journal
    • /
    • no.43
    • /
    • pp.7-35
    • /
    • 2015
  • The Ministry of Public Safety and Security was established in order to handle all sorts of disasters because of Sewol ferry tragedy and the fundamental reform on the emergency management system will be performed. The establishment of the Ministry of Public Safety and Security is considered as the landmark for the emergency management when it is compared to those in the United States and Japan in terms of the size and the authority. However, there are many tasks to be done for the settlement of the Ministry of Public Safety and Security. More specifically, a real and substantial plan should be prepared because the organization was established without blueprints or detailed implementation plan. This study suggests that all-hazard approach which is the one of the disaster management principles should be applied when the substantial plan is prepared. All possible hazard should be analyzed, assessed, and prioritized. In addition, Based on the results, the effective policies should be established with the consideration of Korean context.

  • PDF

IDENTIFICATION OF SAFETY CONTROLS FOR ENGINEERING-SCALE PYROPROCESS FACILITY

  • MOON, SEONG-IN;SEO, SEOK-JUN;CHONG, WON-MYUNG;YOU, GIL-SUNG;KU, JEONG-HOE;KIM, HO-DONG
    • Nuclear Engineering and Technology
    • /
    • v.47 no.7
    • /
    • pp.915-923
    • /
    • 2015
  • Pyroprocess technology has been considered as a fuel cycle option to solve the spent fuel accumulation problems in Korea. The Korea Atomic Energy Research Institute, Daejeon, Korea has been studying pyroprocess technology, and the conceptual design of an engineering-scale pyroprocess facility, called the Reference Engineering-scale Pyroprocess Facility, has been performed on the basis of a 10 ton heavy metal throughput per year. In this paper the concept of Reference Engineering-scale Pyroprocess Facility is introduced along with its safety requirements for the protection of facility workers, collocated workers, the off-site public, and the environment. For the identification of safety structures, systems, and components and/or administrative controls, the following activities were conducted: (1) identifying hazards associated with operations; (2) identifying potential events associated with these hazards; and (3) identifying the potential preventive and/or mitigative controls that reduce the risk associated with these accident events. This study will be used to perform a safety evaluation for accidents involving any of the hazards identified, and to establish safety design policies and propose a more definite safety design.

The Current VIP Guard System and Its Development (요인의 안전을 위한 경호조직 분석 및 발전 방안)

  • 오세용;김창은
    • Journal of the Korea Safety Management & Science
    • /
    • v.5 no.3
    • /
    • pp.81-98
    • /
    • 2003
  • In modern society, there are diverse sorts of VIPs including a king and individuals. Some like a king or president are in need of professional secret services, and others become VIPs by being guarded by a bodyguard company at their own request. The former is called a public guard, and the latter is a private one. In the field of the public guard, the nation should be furnished with a guard system in consideration of political circumstances to protect VIPs. That is, the parliamentary cabinet system and presidential system call for a different guard system, and the guard system's professional features vary to some degree with political situations and cultural climate. If the ultimate goal of guard is to protect the chief of the democratic and open state in a most efficient and safe manner, it's mandatorily necessary to set up a professional and specialized guard organization to provide democratic and efficient secret services. It's desired that the domestic presidential guard division should be staffed with not only expert guards but other personnels dispatched from the military and police. In the police, guard mission is splitted among various guard and security agencies, including the National Police Agency's public security bureau or the Seoul Metropolitan Police Agency's public security division, 101 security unit, mobile police and 22 special guard division. As a chain of command is separated and it's difficult to manage such organizations effectively, the National Police Agency should be exclusively in charge of VIP guard and security. In the area of private guard, the private police system has shared national security task as a middle organization between the private police and private guard. But now its intent has gradually weakened, and its mission should be redefined. In addition, the way people look at private guard should change, and they should be well informed that it could serve to prevent possible crimes, protect them against crimes and get rid of their inconveniences. To make a good impression on people, the guard associations and businesses should put their efforts into reinforcing publicity activities, and the government, academic circles and press should team up with them as well.

Comparative study on internal and external SMS(Safety Management System) to improve the Korean railway's SMS (국내 철도 안전관리체계 개선을 위한 국내외 비교 연구)

  • Kang, Chul;Kim, Sa-Kil;Byun, Seong-Nam
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.538-542
    • /
    • 2007
  • This study proposes SMS(Safety Management System) improvement of domestic railway by intensively comparing railway safety system overseas to reinforce domestic railway safety. UK railways well known the well-organized railway SMS has brought up safety issues on their process of private management. With this process, also, domestic SMS improvements is requested by increasing sense of the safety for general public. This study expects Korean railways to become a well-organized that as removing insecure factors of domestic railway based on result comparing and analyzing the manual, factors and requirements of guideline for internal and external SMS.

  • PDF

Development of Remote Supervision System for Guam Lamps by Way of Leakage Current(Igr) Detection Method (보안등 전거설비의 Igr 누설전류 검출 및 원격감시장치 개발)

  • Choi, Myeong-Il;Kim, Young-Seok;Kim, Chong-Min;Bang, Sun-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.75-80
    • /
    • 2010
  • The present study presented the implementation of a remote control/supervision system for guard lamps used in public illumination with little endeavor by far for safe management, which makes possible to supervise the state and to control the functions remotely including electric safety elements. Especially, the developed system adopts the measurement algorithm for detecting resistive leakage current(Igr) flowing based on the phase difference checkable for sensing at a monitor, being allowable for monitoring at MMI and transmitter for data transmittance. To verify reliability about the algorithm to accurately detect Igr leakage current, the laboratory-based functional test was performed.

Development Of Power Information Management System For Customer Power Manager and Consumer Participation Type Oriented (수용가 전력관리자와 일반 소비자 참여형 전력정보관리시스템 구축)

  • Jung, Hyung-Yong;Yoo, Sang-Bong;Lee, Ki-Chul;Lee, Cheo-Jick
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.480-484
    • /
    • 2015
  • As the increasing national power crises due to various environmental factor, power market change is needed more developed and systemized DSM(Demand Side Management) search at DR market. To overcome national power crisis outbreaking every year and manage the eletric power reserve ratio, we need to construct and develop the electric safety manager and general public main oriented national power plant. For the advanced national power demand management system, it is required the application development like OpenAPI, Big Data Acquisition, Web/APP basd on ICT.

A Study on the Level of BCMS(Business Continuity Management System) of Small and Medium Enterprises (중소기업의 재해경감활동관리체계 수준진단(Checklist)에 관한 연구)

  • Lee, Mi Sun;Kim, Min Ji;Kim, Do Yeon
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.122-128
    • /
    • 2017
  • Recently, accidents such as human accidents are increasing rapidly due to natural disasters and changes in social conditions due to abnormal weather. As a result, damage has been causing massive damage unlike the past. In the case of small and medium enterprises excluding financial institutions and big company, there is no system for prevention and restoration for stable operation from various risks such as human and natural disasters. As the current disaster continues, public and private companies have raised the need for BCM, and with the introduction of the ISO22301 certification system, the company has been establishing and operating Enterprise Disaster Management Standards in the Ministry of Public Safety and Security since 2007. However, in most SMEs, it is hard to bear the input of internal labor and investment cost, and there is a lack of personnel with expertise to conduct BCM diagnosis. Therefore, in this paper, we will study the diagnosis level of enterprise continuity plan which is commonly used in Korea and abroad. Based on this, we will study the BCM system diagnosis method which can be applied to small and medium enterprises in Korea efficiently.

On the Optimal Routing for City-Wide Synchronous PRT (도심지 서비스를 위한 Synchronous PRT의 최적경로설정)

  • Kim, Dong-Hee
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.3
    • /
    • pp.315-320
    • /
    • 2010
  • Recently, there are environmental issues for sustainable transportation system to pursue the energy-efficient and environment-friendly public urban transit. These transportation system needs to offer demand-oriented high-quality service being on the same level with cab service for urban space. PRT(Personal Rapid Transit), small track-guided vehicle, is repeatedly mentioned as a possible alternative for the new urban public transportion system, but but there are not many researches on the operational optimal routing for PRT network. In this paper, the concept of PRT and general optimal routing methods are reviewed. And we suggest the optimal routing method for city-wide PRT network with multi-vehicles and stations, junctions and directional arcs. Futher research directions for PRT routing are presented.