• Title/Summary/Keyword: Protection system

Search Result 5,910, Processing Time 0.039 seconds

A Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA (국가 기간 시설물의 전식 대책(안))

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1609-1611
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) system of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system, Boding ICCP system. In this paper, the mechanism of mitigation method of DC stray current for underground metallic structures is described.

  • PDF

A Case Study(1) of Mitigation Methode of DC Stray Current for Underground Metallic Structures in KOREA (국가기간시설물의 전식대책(안) 및 그 적용 사례(1))

  • Bae, Jeong-Hyo;Ha, Yoon-Cheol;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1612-1614
    • /
    • 2007
  • The owner of underground metallic structures (gas pipeline, oil pipeline, water pipeline, etc) has a burden of responsibility for the corrosion protection in order to prevent big accidents like gas explosion, soil pollution, leakage and so on. So far, Cathodic Protection(CP) technology have been implemented for protection of underground systems. The stray current from DC subway system in Korea has affected the cathodic protection (CP) design of the buried pipelines adjacent to the railroads. In this aspect, KERI has developed a various mitigation method, drainage system through steel bar under the rail, a stray current gathering mesh system, insulation method between yard and main line, distributed ICCP(Impressed Current Cathodic System), High speed response rectifier, restrictive drainage system. We installed the mitigation system at the real field and test of its efficiency in Busan and Seoul, Korea. In this paper, the results of field test, especially, distributed ICCP system is described.

  • PDF

IMPROVING THE LEGAL SYSTEM AND STRENGTHENING THE CONTROL OF ENVIRONEMNT

  • Bin, Zhang
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.473-477
    • /
    • 1993
  • Improving the legal system is one of the key points in strengthening the control of environment . The coordination of economic development with environment protection and the legislation in Guangdong since 1980 is described. Some proposals for stimulating the economy by enhancing the environment protection in accordance with the law are offered.

  • PDF

A Study on Fire Protection in Nuclear Power Plants and Application of the Code and Standards for Fire Protection Systems (원자력발전소 화재방호와 소방시설 기술기준 적용에 대한 고찰)

  • Kim, Wee-Kyong;Jeong, Kee-Sin
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.38-44
    • /
    • 2012
  • The purpose of fire protection for the nuclear power plants (NPPs) is to ensure safe shutdown state of the reactor, to minimize the release of radioactive materials to the environment, to provide physical safety of the on-site personnel, and to limit the property damage. Fire protection and extinguishing equipments are one of the important protection measures based on the defense-in-depth concept, which can promptly detect and control and extinguish those fires that do occur, thereby limiting fire damage. However, a separate evaluation process might be additionally necessary for the construction permit and operating license because the fire protection laws of the NEMA for installation standards of the fire protection systems is not fully characterized for the NPPs. It is also not easy to implement the regulations such as the performance based design concept for fire protection system of the NPPs which are characterized for a relatively low density of employee. This study suggests a guideline for the improvement of the technical standards for fire protection systems of the NPPs by evaluating the fundamental problems drawn by reviewing laws and regulatory guides relevant to fire protection and by evaluating the applicability of the KEPIC FPN in domestic nuclear power plants.

Protection Coordination Strategy of Microgrid Demonstration Site (마이크로그리드 실증사이트의 보호협조 전략)

  • Jin, Dae-Geun;Choi, Won-Jun;Won, Dong-Jun;Lee, Hak-Ju;Chae, Woo-Kyu;Park, Jung-Sung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.966-973
    • /
    • 2012
  • In microgrid demonstration site, distributed generations can make bidirectional power flows on the system. If an accident occurs, the fault current from the inverter based distributed generation is small. However, the conventional protection scheme in distribution network is designed to operate at high fault current. This means that the traditional protection of distribution network is no longer applicable and new protection methods must be developed. In this paper, for two cases, algorithms for protection coordination of demonstration site is proposed and verified through PSCAD/EMTDC simulation. In first case, protection devices are assumed to have the abilities of directional relaying and communication. In second case, protection devices do not have those abilities. Proposed protection coordination algorithms detect the fault locations and protect the microgrid fairly well.

Stochastic Method to Assess Voltage Sag Performance Considering Sag Duration in Large Power System (대규모 계통에서의 순간전압강하 지속시간을 고려한 추계적 평가 방법)

  • Lee, Myeong-Cheol;Park, Chang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.30 no.2
    • /
    • pp.85-92
    • /
    • 2016
  • The paper presents a method to assess system voltage sag performance considering sag durations as well as magnitudes. In general, voltage sag assessment for large power systems is performed only considering sag magnitudes at sensitive load points. However some equipment can be affected by certain sag durations. The duration of the voltage sag is depend on the time of fault current flow in the system. Therefore, the duration can be determined by analyzing the operating characteristic of the protection system. In this paper, an effective method to evaluate sag durations regarding the characteristics and failure rates of the protection system is described. The proposed method can be used to assess the long-term performance of the voltage sags in large power system.

A Study on the Effective Coordination Scheme of Recloser for the Conventional Distribution System Interconnected Dispersed Generation (배전계통에 분산전원 연계시 기존 배전 계통측의 효과적인 리클로저 보호협조 연구)

  • Jung, Seung-Bock;Kim, Jae-Chul;Moon, Jong-Fil;Yun, Sang-Yun;Choi, Joon-Ho;Bae, Joo-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.533-535
    • /
    • 2002
  • In Korea, power requirement has been increasing. But the large generation unit is hardly installed because of economic and environment problem. Therefore, the concern of dispersed generation system(DGS) is growing. The power distribution system is generally operated with radial type. The protection system is composed of one directive source. But power distribution system inserted DGS changes it to two directive source system. Therefore, the insertion of DGS has the problem of protection coordination. In this paper, we argue fault current affected by interconnected DGS. We analyze fault current flow affected by DGS placement. Then, we find protective coordination problem. Consequently, we study advance point for protection scheme of power system interconnected DGS.

  • PDF

Real Time Watermark Embedding/Detecting System for HDTV

  • Hahm Sang Jin;Lee KeunSik;Park KenuSoo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.285-288
    • /
    • 2004
  • High-quality digital broadcasting contents are susceptible to illegal copy and unauthorized redistribution, which makes broadcasters difficult to protect valuable media assets. So, broadcasters and content providers need the technology for copyright protection of professional digital content. Digital watermarking technology is one of the most actively developed solutions for the copyright protection. This paper suggests the requirements of watermarking technology in DTV(Digital TV) environment for copyright protection and shows the developed real-time watermark embedding/detecting system for HD(High Definition)/SD(Standard Definition) video and experimental results of the system against watermark attack tests. Our watermarking system meets the watermarking requirements of invisibility, robustness and security of DTV environment.

  • PDF

A Study on SFCL Systems for Future Korean T&D Power System Application Considering Auto Reclosing Actions of Protection System (미래 송배전계통에서의 자동재폐로 동작을 고려한 초전도한류시스템에 관한 연구)

  • Lee Seung Ryul;Kim Jong-Yul;Yoon Jae Young
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.12
    • /
    • pp.580-585
    • /
    • 2005
  • The recovery time of developing SFCL(Superconducting Fault Current Limiter) has an uncertainty. In general, the recovery time is estimated at 1 sec and more, even though the progress of SFCL technology is considered. However, auto reclosing time of circuit breaker is 0.3 or 0.5 sec in Korean power system. It is impossible to apply only one SFCL to power system because the recovery time is over the reclosing time of protection system. This study proposes two new SFCL systems for power system application. The proposed systems consider auto reclosing action for the protection in practical power system and consist of tow parallel SFCLs.

Analysis on underwater stability of the jellyfish sting protection net installed in the Haeundae beach (해운대 해수욕장에 설치된 해파리 차단망의 수중 안정성 분석)

  • Park, Seongwook;Lee, Donggil;Yang, Yongsu;Lee, Hyungbeen;Lee, Kyounghoon;Hahn, Minsoo;Lee, Taewha
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.1
    • /
    • pp.128-135
    • /
    • 2015
  • The worldwide abundance of various jellyfish appears to have increased in coastal ecosystems in recent years. The enormous jellyfish blooms cause a variety of problems for the local ecology, fisheries, and aquatic-sports in coastal locations. In this study, jellyfish sting protection net was installed to ensure the safety and reduction of the inflow into the Haeundae beach. In order to confirm the stability of the protection net, the tension for protection net was measured from variation of current speed. The periods for maximum tension were observed correspond to the periods of maximum current speed. The maximum tension for protection net was measured up to 4,100 kg. From field evaluations, the jellyfish sting protection net has demonstrated to stability from the current and tide in the Haeundae beach.