• 제목/요약/키워드: Protection method

검색결과 3,805건 처리시간 0.033초

Method to Prevent the Malfunction Caused by the Transformer Magnetizing Inrush Current using IEC 61850-based IEDs and Dynamic Performance Test using RTDS Test-bed

  • Kang, Hae-Gweon;Song, Un-Sig;Kim, Jin-Ho;Kim, Se-Chang;Park, Jong-Soo;Park, Jong-Eun
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1104-1111
    • /
    • 2014
  • The digital substations are being built based on the IEC 61850 network. The cooperation and protection of power system are becoming more intelligent and reliable in the environment of digital substation. This paper proposes a novel method to prevent the malfunction caused by the Transformer Magnetizing Inrush Current(TMIC) using the IEC 61850 based data sharing between the IEDs. To protect a main transformer, the current differential protection(87T) and over-current protection(50/51) are used generally. The 87T IED applies to the second harmonic blocking method to prevent the malfunction caused by the TMIC. However, the 50/51 IED may malfunction caused by the TMIC. To solve that problem, the proposed method uses a GOOSE inter-lock signal between two IEDs. The 87T IED transmits a blocking GOOSE signal to the 50/51 IED, when the TMIC is detected. The proposed method can make a cooperation of digital substation protection system more intelligent. To verify the performance of proposed method, this paper performs the real time test using the RTDS (Real Time Digital Simulator) test-bed. Using the RTDS, the power system transients are simulated, and the TMIC is generated. The performance of proposed method is verified in real-time using that actual current signals. The reaction of simulated power system responding to the operation of IEDs can be also confirmed.

리츠 법을 이용한 열방어 시스템 패널의 열 좌굴 특성 연구 (Thermal Buckling Characteristics for Thermal Protection System Panel Using Ritz Method)

  • 이희수;김용하;박정선
    • 항공우주시스템공학회지
    • /
    • 제13권1호
    • /
    • pp.18-28
    • /
    • 2019
  • 초고속 비행체는 발사 및 재진입 시 공력 가열에 의해 높은 열 하중을 받는다. 초고속 비행체의 외피 구조물인 열방어 시스템 패널은 기계적으로 구속되어 있기 때문에 고온 가열 시 열 좌굴이 발생할 수도 있다. 이는 초고속 비행체의 유동장에 변화를 주어 공력특성을 불안정하게 한다. 따라서 열방어 시스템 패널은 초고속 비행에 의한 공력가열 시 비행안정성을 유지하기 위해 열 좌굴을 방지하도록 설계되어야 한다. 본 논문에서는 운용 시 안팎에 큰 온도차가 존재하는 열방어 시스템 패널에 대해 유한차분법을 사용하여 열전달 특성을 분석하였으며, 리츠 법을 사용하여 열 좌굴 특성에 대한 근사적 모델을 제안하였다. 또한 정의된 근사적 모델의 정확도를 검증하기 위해 유한요소 해석결과와 비교하였다. 마지막으로, 수립된 근사 기법을 바탕으로 열방어 시스템 패널의 좌굴 발생 온도에 대한 매개변수 분석을 수행하였다.

위성통신에서 강우 감쇠 보상을 위한 UEP 방식의 계층적 부호화 방식 (Hierarchical Channel Coding Scheme Using UEP Method for Rain-Attenuation Compensation in Satellite Communication)

  • 정지원
    • 한국전자파학회논문지
    • /
    • 제17권9호
    • /
    • pp.795-803
    • /
    • 2006
  • 본 논문에서는 Ka 대역 초고속 위성 방송 시스템에서 강우 감쇠에 대처하면서 가입자에게 지속적으로 방송을 제공하기 위해 unequal error protection(UEP) 방식을 이용한 계층적 부호화 방식에 대한 연구를 하였다. 신호의 중요도에 따라 변조 방식 및 채널 코딩 방식을 달리하는 time sharing 방식과 달리 하나의 변조 방식을 이용하여 성상도 위치에서 신호의 중요도에 따라 신호간의 최소 거리를 다르게 배치하는 UEP 방식에 대한 구조 및 성능을 분석하였으며, 성능 분석을 토대로 최적의 방식을 제시하였다.

On-line Estimation of DNB Protection Limit via a Fuzzy Neural Network

  • Na, Man-Gyun
    • Nuclear Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.222-234
    • /
    • 1998
  • The Westinghouse OT$\Delta$T DNB protection logic heavily restricts the operation region by applying the same logic for a full range of operating pressure in order to maintain its simplicity. In this work, a fuzzy neural network method is used to estimate the DNB protection limit using the measured average temperature and pressure of a reactor core. Fuzzy system parameters are optimized by a hybrid learning method. This algorithm uses a gradient descent algorithm to optimize the antecedent parameters and a least-squares algorithm to solve the consequent parameters. The proposed method is applied to Yonggwang 3&4 nuclear power plants and the proposed method has 5.99 percent larger thermal margin than the conventional OT$\Delta$T trip logic. This simple algorithm provides a good information for the nuclear power plant operation and diagnosis by estimating the DNB protection limit each time step.

  • PDF

BEM을 이용한 Cathode 방식 시스템에서 전극 위치 최적화 (Optimum Location of Electrode of Cathodic Protection System by using Boundary Element Method)

  • 이광호;정군석;백동철;조윤현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.772-774
    • /
    • 2000
  • The objective of a cathodic protection system (CP) is to protect the buried metallic structure against the corrosion caused by chemical reaction between the buried structure and the surrounding medium, such as soil. This paper presents a boundary element application to determine the optimal impressed current densities in a cathodic protection system. The potential within the electrolyte is described by the Laplace's equation with nonlinear boundary conditions which are enforced based on experimentally determined electrochemical polarization curves. The optimal impressed current densities are determined in order to minimize the power supply for protection. The solution is obtained by using the conjugate gradient method in which the governing equations and the protecting conditions are taken into account by the penalty function method. Numerical example are presented to demonstrate the practical applicability of the proposed method.

  • PDF

통합 전력품질 제어기의 과전류 보호방법에 관한 연구 (A Study on Over Current Protection Method of Unified Power Quality Conditioners)

  • 채범석;이우철;이택기;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.543-547
    • /
    • 2001
  • A protection scheme for Unified Power Quality Conditioner (UPQC) is presented and analyzed in this paper. The proposed UPQC has the series active power filter operated as a high impedance k($\Omega$) to the fundamentals when short-circuit faults occur in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame(SRF) and the third is the method by detecting the input voltage. When the short-circuit fault occur in the power distribution system, the proposed scheme protects the UPQC without additional protection circuits. The validity of proposed protection scheme is investigated through simulation results.

  • PDF

공동주택에서 SPD의 리드선 길이 및 보호거리에 대한 영향 평가 (Evaluation of the Impacts of SPD Connecting Lead Lengths and SPD Protection Distance to the Apparatus in Apartments)

  • 이기홍;강무성
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.94-101
    • /
    • 2011
  • The proper installation of SPD and the evaluation of the SPD protection distance are basic steps for the effective protection measures of apparatus against surges within a structure. A novel method for installing SPD on the conventional distribution board without any modification was proposed and it's effectiveness was evaluated by experiments. Also, the transient overvoltage occurred across the power line from the SPD to the load was simulated with EMTP software to see how different the protection distances affecting the magnitude of the transient overvoltage. As evaluated, the effective protection method of apparatus against surges, coordinated SPD protection system is suggested as a proper measure to protect within the apartment.

넷필터 프레임워크를 이용한 침입 탐지 및 차단 시스템 개발 (A Development of Intrusion Detection and Protection System using Netfilter Framework)

  • 백승엽;이건호;이극
    • 융합보안논문지
    • /
    • 제5권3호
    • /
    • pp.33-41
    • /
    • 2005
  • 네트워크 및 인터넷시장의 발전과 더불어 침해사고도 급증하고 있으며 그 방법도 다양해지고 있다. 이를 방어하기 위해 여러 가지 보안시스템이 개발되어 왔으나 관리자가 수동적으로 침입을 차단하는 형식을 띄고있다. 본 논문에서는 침입탐지 시스템의 패킷 분석능력과 공격에 대한 실시간 대응성을 높이기 위하여 리눅스 OS에서 방화벽기능을 담당하는 넷필터를 이용해 침입탐지 및 차단시스템을 설계하였다.

  • PDF

Arm Short 보호 기능을 포함한 다기능 IGBT GATE DRIVER (Multi Function IGBT Gate Driver Including Arm Short Protection)

  • 이경복;조국춘;최종묵
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.202-209
    • /
    • 2000
  • This paper introduces the main function and protection method of IGBT gate driver that designed by KOROS. Recently, the applications of insulated gate bipolar transistors(IGBTs) have expanded widely, particularly in the area of railway converters. This driver is suitable for railway traction applications, so they are designed for circumstance of railway vehicle such as vibration. The input control power for this driver is supplied from battery charger of railway. it is no necessary an isolated power supply board or auxiliary power supply, with substantial savings in cost and space in railway applications. This gate driver can be used wide range of input voltage. So, performance of the driver has no relation with the battery voltage(70V∼110V). The protection methods of IGBT gate driver have many kind of ways, but this gate driver it designed to apply to converter for railway system, so this gate driver includes protection for arm short current and low control power voltage, etc. And the process of protection method and protection reference value are optimized by means of sufficient test with our own facilities.

  • PDF

A Novel Procedure for Protection Setting in an HVDC System Based on Fault Quantities

  • Gao, Benfeng;Zhang, Ruixue;Zhang, Xuewei
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.513-521
    • /
    • 2017
  • HVDC protection setting is difficult to be calculated analytically because of its strong nonlinearity. The currently used setting method is based on the empirical setting of previous projects and then verified by digital simulation. It entails a huge workload and low efficiency. To facilitate protection setting, this paper systematically summarizes the HVDC protection characteristics and then presents a classification of HVDC protections according to the protection principles. On the basis of the fault quantities, a novel setting procedure suitable for travelling wave protection, derivative and level protection, and differential protection is proposed. The proposed procedure is illustrated and verified in detail with the example of travelling wave protection. An HVDC protection setting system that has the functions of automatic protection setting and data management is developed utilizing the C# programming language.