• Title/Summary/Keyword: Protection facility

Search Result 406, Processing Time 0.027 seconds

Hydrogeologic and Hydrogeochemical Assessment of Water Sources in Gwanin Water Intake Plant, Pocheon (포천 관인취수장 수원에 대한 수리지질 및 수리지구화학적 평가)

  • Shin, Bok Su;Koh, Dong-Chan;Chang, Yoon-Young
    • Journal of Environmental Impact Assessment
    • /
    • v.25 no.3
    • /
    • pp.209-221
    • /
    • 2016
  • The section from water source to 2.6km upper stream of Hantan River is protected as the drinking water quality protection area according to guidelines of Ministry of Environment, because water source of the Gwanin water intake plant has been known the river. However, opinions were consistently brought up that the standard of water source protection zone must be changed with using underground water as water source because of contribution possibility of underground water as the water source of Gwanin water intake facility. In this regard, hydrogeologic investigation including resistivity survey and hydrogeochemical investigation were carried out to assess water source and infiltration of contaminant for the plant. Quaternary basaltic rocks (50m thick with four layers) covered most of the study area on the granite basement. As the result of the resistivity survey, it is revealed that permeable aquifer is distributed in the boundary of two layers: the basaltic layer with low resistivity; and the granite with high resistivity. Considering of outflow from Gwanin water intake facility, the area possessing underground water was estimated at least $5.7km^2$. The underground water recharged from Cheorwon plain was presumed to outflow along the surface of unconformity plane of basalt and granite. Based on field parameters and major dissolved constituents, groundwater and river water clearly distinguished and the spring water was similar to groundwater from the basaltic aquifer. Temporal variation of $SiO_2$, Mg, $NO_3$, and $SO_4$ concentrations indicated that spring water and nearby groundwater were originated from the basaltic aquifer and other groundwater from granitic aquifer. In conclusion, the spring of the Gwanin water intake plant was distinguished from river water in terms of hydrogeochemical characteristics and mainly contributed from the basaltic aquifer.

Performance Estimation of Large-scale High-sensitive Compton Camera for Pyroprocessing Facility Monitoring (파이로 공정 모니터링용 대면적 고효율 콤프턴 카메라 성능 예측)

  • Kim, Young-Su;Park, Jin Hyung;Cho, Hwa Youn;Kim, Jae Hyeon;Kwon, Heungrok;Seo, Hee;Park, Se-Hwan;Kim, Chan Hyeong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Compton cameras overcome several limitations of conventional mechanical collimation based gamma imaging devices, such as pin-hole imaging devices, due to its electronic collimation based on coincidence logic. Especially large-scale Compton camera has wide field of view and high imaging sensitivity. Those merits suggest that a large-scale Compton camera might be applicable to monitoring nuclear materials in large facilities without necessity of portability. To that end, our research group have made an effort to design a large-scale Compton camera for safeguard application. Energy resolution or position resolution of large-area detectors vary with configuration style of the detectors. Those performances directly affect the image quality of the large-scale Compton camera. In the present study, a series of Geant4 Monte Carlo simulations were performed in order to examine the effect of those detector parameters. Performance of the designed large-scale Compton camera was also estimated for various monitoring condition with realistic modeling. The conclusion of the present study indicates that the energy resolution of the component detector is the limiting factor of imaging resolution rather than the position resolution. Also, the designed large-scale Compton camera provides the 16.3 cm image resolution in full width at half maximum (angular resolution: $9.26^{\circ}$) for the depleted uranium source considered in this study located at the 1 m from the system when the component detectors have 10% energy resolution and 7 mm position resolution.

Monitoring the Reoccurrence of Fire Blight and the Eradication Efficiency of Erwinia amylovora in Burial Sites of Infected Host Plants Using Sentinel Plants (미끼식물을 이용한 화상병 감염 기주 매몰지 내 화상병균 제거 효율 검증 및 병 재발 모니터링)

  • In Woong, Park;Yu-Rim, Song;Nguyen Trung, Vu;Eom-Ji, Oh;In Sun, Hwang;Hyeonheui, Ham;Seong Hwan, Kim;Duck Hwan, Park;Chang-Sik, Oh
    • Research in Plant Disease
    • /
    • v.28 no.4
    • /
    • pp.221-230
    • /
    • 2022
  • The fire blight caused by Erwinia amylovora (Ea) was first reported in 2015 in Korea, and the disease has rapidly spread to 22 regions until 2021. In Korea, all host plants in the apple and pear orchards where fire blight occurred should be eliminated and buried by the Plant Protection Act. To prevent the spread of the disease, all burial sites were prohibited from planting the new host plants for the next three years. To confirm the eradication efficiency of Ea and the reoccurrence of fire blight, the surveillance facilities were established on three burial sites from 2019 to 2020 in Anseong-si, Gyeonggi-do, and Chungju-si, Chungcheongbuk-do. As host plants, five apple trees of fire blight-susceptible cultivar 'Fuji', were planted in each facility. All facilities were enclosed with fences and nets and equipped with two CCTVs, motion sensors, and several other sensors for recording weather conditions to monitor the environment of the sentinel plants in real-time. The sentinel plants were checked for the reoccurrence of fire blight routinely. Suspicious plant parts were collected and analyzed for Ea detection by loop-mediated isothermal amplification polymerase chain reaction and conventional polymerase chain reaction. Until November 2022, Ea has not been detected in all sentinel plants. These results might support that the burial control of infected plants in soil works efficiently to remove Ea and support the possibility to shorten the prohibition period of host plant establishment in the burial sites.

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

Assessment of the Value and Distribution of Geological Heritages in Korea: Jeolla Province (한국의 지질유산 분포와 가치평가: 전라권)

  • Cho, Hyeongseong;Kang, Hee-Cheol;Kim, Jong-Sun;Cheong, Daekyo;Paik, In Sung;Lim, Hyoun Soo;Choi, Taejin;Kim, Hyun Joo;Roh, Yul;Cho, Kyu-Seong;Huh, Min;Shin, Seungwon
    • The Journal of the Petrological Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.319-345
    • /
    • 2019
  • Recently planification and effort for management, assessment and discovery of geological heritagesare being increasingly demanded with institutional strategies such as geopark, as their preservation is asked socially. In this study, we discovered geological heritages in the Jeolla Province and then performed assessment of the value and grading of them and finally suggested a promising and suitable site for the National Geopark. A total of 325 geological heritages are listed on literature review and then detailed description in field and assessment of the value for selected 158 geoheritages are completed. The assessment items are categorized into intrinsic value, subsidiary value, and preservation/management part. The intrinsic value is subdivided into scientific/educational value, composed of representativeness, rarity, geodiversity, typicality, reproducibility, and particularity, and geomorphological/landscape value composed of scale, naturality (integrity), scenery (aesthetic value). Also, subsidiary value consist of 7 subsections of soil function, ecological function, tourism value, geological resource, historical value, folk tale or legend and symbolic value, and accessibility, convenient facility (infrastructure), management condition (legal protection) is evaluated in preservation/management part. The heritages in the Jeolla Province subdivided into three types: 73 geological heritages, 42 geomorphological heritages, and 42 composite heritages. Based on points acquired in intrinsic value, all geological heritages are graded Class-I to -V. As a result, numbers of geoheritage belong to Class-I (protection at world level), -II (protection at national level), -III (nationdesignated management), -IV (involved management list), -V (candidate management list) are 12, 39, 52, 34, 21, respectively. Finally, we construct database based on Arc-GIS with all informations for each geological heritage and suggest three promising and suitable sites, 'Jirisan-Seomjingang Area' and 'south coast area of Jeolla Province', for the National Geopark.

Development of Standard Process for Private Information Protection of Medical Imaging Issuance (개인정보 보호를 위한 의료영상 발급 표준 업무절차 개발연구)

  • Park, Bum-Jin;Yoo, Beong-Gyu;Lee, Jong-Seok;Jeong, Jae-Ho;Son, Gi-Gyeong;Kang, Hee-Doo
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.335-341
    • /
    • 2009
  • Purpose : The medical imaging issuance is changed from conventional film method to Digital Compact Disk solution because of development on IT technology. However other medical record department's are undergoing identification check through and through whereas medical imaging department cannot afford to do that. So, we examine present applicant's recognition of private intelligence safeguard, and medical imaging issuance condition by CD & DVD medium toward various medical facility and then perform comparative analysis associated with domestic and foreign law & recommendation, lastly suggest standard for medical imaging issuance and process relate with internal environment. Materials and methods : First, we surveyed issuance process & required documents when situation of medical image issuance in the metropolitan medical facility by wire telephone between 2008.6.1$\sim$2008.7.1. in accordance with the medical law Article 21$\sim$clause 2, suggested standard through applicant's required documents occasionally - (1) in the event of oneself $\rightarrow$ verifying identification, (2) in the event of family $\rightarrow$ verifying applicant identification & family relations document (health insurance card, attested copy, and so on), (3) third person or representative $\rightarrow$ verifying applicant identification & letter of attorney & certificate of one's seal impression. Second, also checked required documents of applicant in accordance with upper standard when situation of medical image issuance in Kyung-hee university medical center during 3 month 2008.5.1$\sim$2008.7.31. Third, developed a work process by triangular position of issuance procedure for situation when verifying required documents & management of unpreparedness. Result : Look all over the our manufactured output in the hospital - satisfy the all conditions $\rightarrow$ 4 place(12%), possibly request everyone $\rightarrow$ 4 place(12%), and apply in the clinic section $\rightarrow$ 9 place(27%) that does not medical imaging issuance office, so we don't know about required documents condition. and look into whether meet or not the applicant's required documents on upper 3month survey - satisfy the all conditions $\rightarrow$ 629 case(49%), prepare a one part $\rightarrow$ 416 case(33%), insufficiency of all document $\rightarrow$ 226case(18%). On the authority of upper research result, we are establishing the service model mapping for objective reception when image export situation through triangular position of issuance procedure and reduce of friction with patient and promote the patient convenience. Conclusion : The PACS is classified under medical machinery that mean indicates about higher importance of medical information therefore medical information administrator's who already received professional education & mind, are performer about issuance process only and also have to provide under ID checking process exhaustively.

  • PDF

Analysis of radiation exposure in radiation worker in medical facility and student in clinical practice (의료기관 방사선작업종사자와 임상실습 학생의 피폭선량 분석)

  • Lee, Joo-Ah;Choi, Kwan-Woo;Min, Jung-Whan;Lim, Jong-Cheon;Son, Soon-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.442-448
    • /
    • 2016
  • This study was conducted to determine the appropriateness of systemic radiation exposure control for students in clinical practice by comparing radiation exposure in radiography employees at different stations of a hospital with that of students conducting clinical practice using identical stations. Overall, 121 students who conducted clinical practice in the department of radiology area of C university hospital from July 2014 to August 2014 and 62 workers working in the same medical facility (47 in the department of radiology, 8 in the department of radiation oncology, 7 in the department of nuclear medicine) were investigated. The radiation exposure experienced by students was measured for 8 weeks, which is the duration of the clinical practice. Additionally, radiation exposure of workers were classified into 4 groups, department of radiology, department of radiation oncology, and department of nuclear medicine was compared. Dose was measured with OSLD and differences among groups were identified by ANOVA followed by Duncan's multiple range test. Among employees, those in the department of radiology, oncology and nuclear medicine were exposed depth doses of $0.127{\pm}0.331mSv$, $0.01{\pm}0.003mSv$, and $0.431{\pm}0.205mSv$, respectively, while students were exposed to $0.143{\pm}0.136mSv$. Additionally, workers in the department of radiology, oncology and nuclear medicine were exposed to surface doses of $0.131{\pm}0.331mSv$, $0.009{\pm}0.003mSv$, and $0.445{\pm}0.198mSv$, respectively, while students were exposed to $0.151{\pm}0.14mSv$, which was significantly different in both doses (p < 0.01). The average dose that students received is higher than that of the other groups (except for nuclear medicine workers), indicating that further improvements must be made in systemic controls for individual radiation exposure by including the students as subjects of management for protection from radiation.

A Leg Analysis on the Discharge of Cargo Residue at Sea (화물잔류물의 해양 투입처분(배출) 사안에 대한 법률적 분석)

  • Hong, Gi-Hoon;Park, Chan-Ho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.4
    • /
    • pp.193-202
    • /
    • 2006
  • The Consultative Meeting of the Convention on the Prevention of Marine Pollution by Dumping of Wastes and other matter, 1972 (London Convention 1972) has requested to International Maritime Organization (IMO) Marine Environmental Protection Committee to collaborate and help clarify a boundary issue between International Convention for the Prevention of Pollution from Shops, 1973 as modified by the Protocol of 1978 (MARPOL) and the London Convention concerning 'dumping' versus 'discharges' during normal operations of ships in 2004, and subsequently established a Joint London Convention/MEPC Correspondence Group. The Contracting Parties to London Convention expressed their environmental concerns on the broad interpretation of the "cargo-associated wastes" by the States, which could be discharged by ships under MARPOL. Regulatory regimes for the cargo residues appear to vary among states. Some countries require fur ships to discharge their cargo wastes into the port reception facility and IMO also recommends doing so. This paper examines the related current national and international legal texts for the regulation of disposal of wastes from ships in order to analyze the current global concern on the marine pollution associated with waste discharge during operations of ships. In particular, we attempt to evaluate the likely marine environmental consequences arising from the disposal of cargo residue using an hypothetical case for the coal cargo residue among bulk cargos in this paper, since location, magnitude and frequency of the discharge of coal cargo residues into the sea adjacent to Korean Peninsula are not readily available. The cargo residues may be discharged to the sea according to MARPOL 73/78; however, its marine environmental consequences can be significant depending upon the characteristics and amounts of wastes to be discharged. Also the public tolerance of the environmental consequences would be widely different among nations. Multilateral environmental agreements, in general, more strictly apply their rules if there are other options to disposal at sea, i.e. port reception facility in this case. Therefore, port reception facilities for the wastes generated by ships are recommended to be further constructed in major national ports in order to reduce the risk of environmental damages during the operations of ships.

  • PDF

Comparative Study of Security Services Industry Act and Police Assigned to Special Guard Act - Focused on special guards and police assigned to special guard duty - (경비업법과 청원경찰법의 비교 연구 특수경비원과 청원경찰을 중심으로)

  • Noh, Jin-keo;Lee, Young-ho;Choi, Kyung-cheol
    • Korean Security Journal
    • /
    • no.57
    • /
    • pp.177-203
    • /
    • 2018
  • Police Assigned to Special Guard Act was legislated in 1962 to solve issues regarding the protection of various staple industrial installations, and in 2001, the Security Services Industry Act was revised to establish an effective security system for important national facilities. Thereby the Special Guards System was instituted. The current law has two parts, with the Police Assigned to Special Guard System and Special Guards System, and many scholars have actively discussed the appropriateness of the integration of both systems to solve problems caused by a bimodal system. However, in spite of these discussions taking place in the academic world, the idea of unification lost its power when the guarantee of status regulation was established for the police assigned to special guard. Strictly speaking, police assigned to special guard is a self-guard, and a special guard is a contractual guard. So, both of them have pros and cons. Thus, it would be desirable to give a legal, constitutional guarantee for both systems by strengthening each of them and making up for the weakness of each of them rather than trying to unify police assigned to special guard and special guard. To begin this process, we need to revise unreasonable legal provisions of Security Services Industry Act and Police Assigned to Special Guard Act as below. First, since the actual responsibilities of special guards and police assigned to special guard duty are the same, we need to make the facilities which they use equal. Second, legal provisions need to be revised so that a special guard may perform the duties of a police officer, according to the Act on the Performance of Duties by Police Officers, within the facility that needs to be secured in order to prevent any vacancy in the guarding of an important national facility. Third, disqualifications for the special guards need to be revised to be the same as the disqualifications for the police assigned to special guard duty. Fourth, it is reasonable to unify the training institution for special guards and for police assigned to special guard duty, and it should be the training institution for police. On-the-job education for a security guard needs to be altered to more than 4 hours every month just like the one for police assigned to special guard duty. Fifth, for a special guard, it is not right to limit the conditions in their using weapons to 'use of weapon or explosives' only. If one possesses 'dangerous objects such as weapon, deadly weapon, and so on' and resists, a special guard should be able to use their weapon against that person. Thus, this legal provision should be revised. Sixth, penalty, range of fines, and so on for police assigned to special guard duty need to be revised to be the same as the ones for a special guard. If we revise these legal provisions, we can correct the unreasonable parts of Security Services Industry Act and Police Assigned to Special Guard Act without unifying them. Through these revisions, special guards and police assigned to special guard duty may develop the civilian guard industry wholesomely under the law, and the civilians would have a wider range of options to choose from to receive high quality security service.

A Study on B Class Fire Extinguishing Performance of Air Ratio in the Compressed Air Foam System (압축공기포 소화설비의 공기포비에 따른 B급 소화성능 연구)

  • Lee, Jang-Won;Lim, Woo-Sub;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.8-14
    • /
    • 2013
  • This research is to evaluate the fire extinguishing performance at a mixing ratio of pressurized air in the fire extinguishing system of compressed air foam (CAF) which injects compressed air into foam liquid and then discharging. The experimental device is made use of exclusive foam extinguishing facility for compressed air foam that is produces based on Canada National Laboratory and UL 162 standard, apply model of oil fire (B Class) 20 unit in accordance with "Standard of Model Approval and Product Inspection for Fire Extinguishing Agent" to the fire Extinguishing model. Compressed air is injected through the air mixture and study the tendency depending on increasing air foam ratio 1 : 4, 1 : 7, 1 : 10. In addition, the comparison experiments between synthetic surfactants foam and AFFF carry out with it at the air foam ratio 1 : 4. As a result, in the condition of same discharging flow, fire extinguishing effect of AFFF is the fastest at the air foam ratio 1 : 7 and the slowest at 1 : 10. Moreover, the fire extinguishing effect of AFFF in the comparison expeiments between AFFF and synthetic surfactants foam is faster than the other.