• Title/Summary/Keyword: Protection devices

Search Result 787, Processing Time 0.027 seconds

A Study on the Information Protection Plan for the Smartwork Service Environments (스마트워크 서비스 환경 구축을 위한 정보보호 방안에 대한 연구)

  • Kim, Dong Soo;Kim, Hee Wan
    • Journal of Service Research and Studies
    • /
    • v.3 no.2
    • /
    • pp.19-32
    • /
    • 2013
  • An explosive growth of mobile devices and smart phones, such as Tablet PC using wireless Internet, is changing the Information environment rapidly. Smart technology telecommuting work or smart work centers, mobile devices, and configure your environment to take advantage of remote collaboration. Also, you do not have the limitations of time and space provides a flexible working environment. Smartwork environment is an IT environment to be provided to carry out the business by accessing remotely via smart device outside of the internal IT infrastructure of an existing. Smartwork system to increase the work efficiency is present to what information protection threats according to their convenience. Safeguards information that can be utilized to build a secure smartwork environment is required. Therefore, in this paper, we examined the worksmart information protection measures that can protect the information be reconciled smoothly to fit the smartwork environment.

  • PDF

Seismic Performance of the Anchor System of Bearing-protection Devices Preventing the Unseating Failure of Bridges (낙교 방지를 위한 받침보호장치의 앵커부 내진성능)

  • Jeong, Hyeok-Chang;Kim, Min-Su;Park, Kwang-Soon;Ju, Hyeong-Seok;Kim, Ick-Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.45-53
    • /
    • 2010
  • The unseating failure of bridges, which is one of the most severe types of damage leading to the loss of transportation function, should be avoided in earthquakes. As a measure of prevention of unseating failure resulting from the failure of bearings, bearing-protection devices are frequently used. They are installed beside the bearings and protect the bearings by resisting a seismic load transmitted from the superstructure. In order to show appropriate seismic performance, the strength of anchors as well as of device bodies should be confirmed. In Korea, they have been installed only according to the design provided by device agents, because a proper design method for the anchors has not been established. In this study the performance of bearing-protection devices with various heights of concrete bed blocks has been investigated experimentally, and a proper design method has been proposed to secure seismic performance.

A Study on the Design of the Output ESD Protection Circuits and their Electrical Characteristics (출력단 ESD 보호회로의 설계 및 그 전기적 특성에 관한 연구)

  • 김흥식;송한정;김기홍;최민성;최승철
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.11
    • /
    • pp.97-106
    • /
    • 1992
  • In integrated circuits, protection circuits are required to protect the internal nodes from the harmful ESD(Electrostatic discharge). This paper discusses the characteristics of the circuit components in ESD protection circuitry in order to analyze the ESD phenomina, and the design methodalogy of ESD protection circuits, using test pattern with a variation of the number of diode and transistor. The test devices are fabricated using a 0.8$\mu$m CMOS process. SPICE simulation was also carried out to relate output node voltage and measured ESD voltage. With increasing number of diodes and transistors in protection circuit, the ESD voltage also increases. The ESD voltage of the bi-directional circuit for both input and output was 100-300[V], which in higher than that of only output(uni-directional) circuit. In addition, the ESD protection circuit with the diode under the pad region was useful for the reduction of chip size and parasitic resistance. In this case, ESD voltage was improved to a value about 400[V].

  • PDF

The Advanced Protection Coordination Scheme using Phase Angle of Zero-Sequence Current in Ungrounded System (비접지 계통에서 영상전류 위상을 이용한 개선된 보호협조 방안)

  • Choi, Young-Jun;Lim, Hee-Taek;Choi, Myeon-Song;Lee, Seung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.19-25
    • /
    • 2010
  • Most faults are single-phase-to-ground fault in ungrounded system. The fault currents of single-phase-to-ground are much smaller than detection thresholds of measurement devices, so detecting single-phase-to-ground faults is difficult and important in ungrounded system. The protection coordination method using SGR(Selective Ground Relay) and OVGR(Overvoltage Ground Relay) is generally used in ungrounded system. But this method only detects fault line and it has the possibility of malfunction. This paper proposed to advanced protection coordination method in ungrounded system. The method just using zero-sequence current can detect fault line, fault phase, fault section at terminal device. The general protection method is used to back up protection. In the case study, the proposed method has been testified in demo system by Matlab/Simulink simulations.

Automatic Protection Schemes for Distribution System with Open and Closed-loop

  • Guan, Kang-Le;Lee, Seung-Jae;Choi, Myeon-Song
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.969-974
    • /
    • 2013
  • Protection issues in distribution systems which are to be operated in open and closed-loop modes in a smart grid are studied and a generalized protection setting method is proposed to meet the new requirements. The developed setting method assumes a conventional over-current protection scheme for the system with reclosers and over-current relays. In a closed-loop mode, it identifies protective devices that have to be sacrificed in order to maximize protection coordination for bidirectional fault current flow. The proposed setting method has been tested on many systems with different complexity and is proved effective.

Realization of Protection IED for Distributed Power System (분산 전원 계통 연계용 보호 IED의 설계 및 구현)

  • Han, Chul-Wan;Oh, Sung-Nam;Kim, Kab-Il;Son, Young-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.517-519
    • /
    • 2005
  • In this paper, we consider a digital protection IED(Intelligent Electric Device) for a distributed power system. The IED can measure various elements for protection and communicate with another devices through network. The protection IED is composed of specific function modules: signal process module which converts analog signal from PT and CT handle algorithm to digital one; communication module for connection with another IEDs; input/output module for user-interfaces. A general purpose DSP board with TMS320C2812 is used in the IED. In order to verify the proposed IED, experimental researches with the power system simulator DOBLE has been carried out for a phase earth fault. The results show an under-voltage relaying algorithm has been realized sucessfully in the hardware system.

  • PDF

Two-Stage Surge Protection Device with Varistor and LC Filter. (바리스터와 LC필터를 사용한 2단 서지보호장치)

  • Lee, B.H.;Kim, J.H.;Lee, K.O.
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.279-281
    • /
    • 1996
  • This paper deals with the two stage surge protection device by using varistor and LC low pass filter. Recently varistor alone has been used with overvoltage protection devices for the AC power mains and has same problems associated with high remnant voltage and noise. In this work, in order to improve the cutoff performance of surge protection device, the lightning surge protection device having two stage hybrid circuit for an AC single phase mains was designed and fabricated. Operation characteristics and surge clamping performance of the surge protection device in an $8/20{\mu}s$ surge current are investigated. As a consequence, it is found that the proposed two stage surge protective device for AC power mains has a variety of advantages such as a smaller clamping voltage, high frequency noise reduction and large clamping capacity.

  • PDF

Effect of Noise Cancelling Devices on Dental Handpieces Using Ear Model (귀 모형을 이용한 치과 핸드피스에 대한 소음 저감 장치의 효과 분석)

  • Mo, Seunghan;Kang, Jungu;Kim, Ik-Hwan;Choi, Hyung-Jun;Song, Je Seon;Shin, Yooseok
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.47 no.1
    • /
    • pp.62-69
    • /
    • 2020
  • This study intended to evaluate noise level of dental handpieces and the effects of noise cancelling devices. An ear model was designed to measure the level of the noise delivered to the inner ear during dental handpiece operation. The level of noise was measured in various conditions using the ear model and the portable noise meter. Noise level was measured again after applying of 4 different noise cancelling devices to the model ear. The noise level of dental handpieces was 82.5 - 84.4 dB. When 4 types of noise canceling devices were applied, the noise level reduced to 67.4 - 73.8 dB. All 4 devices had statistically significant effect in reducing the noise of the handpiece. Considering the intensity and exposure time, noise in dental clinics can cause hearing damage to dentists. For protection from the risk of occupational hearing damages, noise canceling devices can be recommended.

UTrustDisk: An Efficient Data Protection Scheme for Building Trusted USB Flash Disk

  • Cheng, Yong;Ma, Jun;Ren, Jiangchun;Mei, Songzhu;Wang, Zhiying
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.4
    • /
    • pp.2276-2291
    • /
    • 2017
  • Data protection of removable storage devices is an important issue in information security. Unfortunately, most existing data protection mechanisms are aimed at protecting computer platform which is not suitable for ultra-low-power devices. To protect the flash disk appropriately and efficiently, we propose a trust based USB flash disk, named UTrustDisk. The data protection technologies in UTrustDisk include data authentication protocol, data confidentiality protection and data leakage prevention. Usually, the data integrity protection scheme is the bottleneck in the whole system and we accelerate it by WH universal hash function and speculative caching. The speculative caching will cache the potential hot chunks for reducing the memory bandwidth pollution. We adopt the symmetric encryption algorithm to protect data confidentiality. Before mounting the UTrustDisk, we will run a trusted virtual domain based lightweight virtual machine for preventing information leakage. Besides, we prove formally that UTrustDisk can prevent sensitive data from leaking out. Experimental results show that our scheme's average writing throughput is 44.8% higher than that of NH scheme, and 316% higher than that of SHA-1 scheme. And the success rate of speculative caching mechanism is up to 94.5% since the access pattern is usually sequential.

Protection Coordination Associated with Connection Location of Residual Current Devices and Surge Protective Devices (RCD와 SPD의 접속 위치에 따른 보호협조)

  • Lee, Bok-Hee;Park, Hee-Yeoul;Shin, Gun-Jin;Bae, Gwan-Young;Ryu, Chun-Hyoung;Lee, Kang-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.100-106
    • /
    • 2013
  • In this paper, in order to analyze lightning impulse response characteristics in combined installations of SPDs and RCDs, surge protection coordination between SPDs and RCDs are experimentally investigated by using the combination wave generator. Six different types of single-phase residual current operated circuit-breakers with integral overcurrent protection for household and similar uses(RCBOs) being present on the domestic market are tested according to KS C IEC 61009-1 standard. As a result, when a class I SPD is located on the source side of an RCBO, all kinds of specimens are able to provide the proper coordination between the SPD and RCBOs without nuisance tripping, unintended operation or damage due to test impulse currents. However, in the case that the class II SPD is located on the load side of RCBOs, a lot of L-N mode injected currents is split into the RCBO, and a few RCBOs are damaged. Coordination between SPDs and RCDs is not valid and a role of SPDs is of no use. When combining SPDs with RCDs, it is necessary to select SPDs and RCDs in consideration of the protection voltage level of metal oxide varistor embedded in RCDs.