• 제목/요약/키워드: Protection algorithm

검색결과 820건 처리시간 0.031초

발전기시스템의 고정자보호 IED를 위한 개선된 알고리즘 (Advanced Algorithm for IED of Stator Winding Protection of Generator System)

  • 박철원
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.91-95
    • /
    • 2008
  • The large AC generator fault may lead to large impacts or perturbations in power system. The generator protection control systems in Korea have been imported and operated through a turn-key from overseas entirely. Therefore a study of the generator protection field has in urgent need for a stable operation of the imported goods. In present, the algorithm using the current ratio differential relaying based DFT for stator winding protection or a fault detection had been applied that of internal fault protection of a generator. the DFT used for the analysis of transient state signal conventionally had defects losing a time information in the course of transforming a target signal to frequency domain. In this paper, the discrete wavelet transform (DWT) was applied a fault detection of the generator being superior to a transient state signal analysis and being easy to real time realization. The fault signals after executing a terminal fault modeling collect using a MATLAB package, and calculate the wavelet coefficients through the process of a muiti-level decomposition (MLD). The proposed algorithm for a fault detection using the Daubechies WT (wavelet transform) was executed with a C language and the commend line function for the real time realization after analyzing MATLAB's graphical interface. The advanced technique had improved faster a speed of fault discrimination than a conventional DFR based on DFT.

소형 미사일 탐지를 위한 Facet 기반의 고속 영상처리 기법 (A High-Speed Image Processing Algorithm Based on Facet Filter for Small Missile Detection)

  • 김지은
    • 한국군사과학기술학회지
    • /
    • 제12권4호
    • /
    • pp.500-507
    • /
    • 2009
  • This paper presents a novel method which can detect a target in IR image for active protection system. The target in IR image for the active protection system is small, moreover it moves with enormous speed. The proposed algorithm is comprised of robust clutter rejection methods and target optimized detection algorithms for small target, and an advanced method of selecting a final target position in target area, it can work in some milliseconds. The proposed algorithm provides the active protective system with more correct positions than those of radar, so that helps the active protection system can defense all threats with the utmost precision.

변류기 포화 곤단 알고리즘으로 억제된 모선보호용 비율 전류차동 계전방식 (A Percentage Current Differential Relaying Algorithm for Bus Protection Blocked by a CT Saturation Detection Algorithm)

  • 강용철;윤재성
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권1호
    • /
    • pp.44-49
    • /
    • 2003
  • This paper describes a percentage current differential relaying algorithm for bus protection blocked by a CT saturation detection algorithm. The detection algorithm blocks the output of a current differential relay only if a differential current is caused by CT saturation in the case of an external fault. Moreover, if a current differential relay operates faster than the detection algorithm, the blocking signal is not ignited. On the other hand. if the detection algorithm operates faster than a current differential relay, the output of the relay is blocked. The results of the simulation show that the proposed algorithm can discriminate internal faults from external faults ever when a CT is saturated in both cases. This paper concludes by implementing the algorithm into the TMS320C6701 digital signal processor. The results of hardware implementation are also satisfactory The algorithm can not only increase the sensitivity of the current differential relay but Improve the stability of the relay for an external faults.

생존도를 고려한 WDM 망의 경로설정 및 파장할당 (Routing and Wavelength Assignment in Survivable WDM Networks)

  • Lee, Taehan;Park, Sungsoo
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회 2001년도 추계학술대회 논문집
    • /
    • pp.124-127
    • /
    • 2001
  • We consider the routing and wavelength assignment problem in survivable WDM transport network without wavelength conversion. We assume the single-link failure and a path protection scheme in optical layer. When a physical network and a set of working paths are given, the problem is to select a link-disjoint protection path for each working path and assign a wavelength for each working and protection path. We give an integer programming formulation of the problem and propose an algorithm to solve it based on column generation technique and variable fixing. We devise a branch-and-price algorithm to solve the column generation problem. We test the proposed algorithm on some randomly generated data and test results show that the algorithm gives very good solutions.

  • PDF

대칭분 전압 단위 벡터를 이용한 송전선로 보호용 고장상 선택 알고리즘 (Fault Phase Selection Algorithm using Unit Vector of Sequence Voltages for Transmission Line Protection)

  • 이명수;이재규;김수남;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권9호
    • /
    • pp.460-466
    • /
    • 2002
  • A reliable fault phase selection algorithm plays a very important role in transmission line protection, Particularly in Extra High Voltage (EHV) networks. The conventional fault phase selection algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to pick out only fault current since we can not know when a fault occurs and select the fault phase in weak-infeed conditions that dominate zero-sequence current in phase current. The proposed algorithm can select the accurately fault phase using the sum of unit vectors which are calculated by positive-sequence voltage and negative-sequence voltage.

풍력발전단지 연계 전용선로 보호용 거리계전 알고리즘 (A Distance Protection Algorithm for a Transmission Line to Interconnect a Wind Farm to a Utility System)

  • 권영진;강상희;최동민;장성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.516-518
    • /
    • 2005
  • This paper presents a distance protection algorithm a lied to the linked line for interconnecting wind farm with the utility. The capacity of wind farm is lower than utility system and its fault current level is very low. When a high resistance fault occurs in the linked line, it is difficult to detect accurate fault distance because of reactance effect. By using the characteristic of equivalent source impedance of induction generator which is compensated by capacitor bank and characteristic of the capacity of wind farm, this paper proposes improved distance protection algorithm applied to the linked line. A series of PSCAD/EMTDC simulation results have shown effectiveness of the proposed algorithm.

  • PDF

크레인 안전을 위한 과부하 방지 알고리즘 개발 (Development of Overload Prevention Algorithm for the Crane Safety)

  • 이상영
    • 디지털산업정보학회논문지
    • /
    • 제8권2호
    • /
    • pp.11-19
    • /
    • 2012
  • Crane systems have been widely used for transportation in building sites, ports, nuclear wastehandling operation and so on. As a typical underactuated system, an overhead crane has such merits as high flexibility and less energy consumption. And it's getting more types of cranes, universally applicable algorithms should be developed. That is the design and development of scalable algorithms are required. Developed algorithms can be used for the controller and crane overload protection that meets the requirements of the algorithm are presented. These algorithms force the state to warn the operator and stops the operation of equipment. In this paper, crane overload conditions that can cause damage to alert the operator, and to limit the operation of equipment overload protection algorithm is presented.

정상 성분 변화량을 이용한 송전선로 보호용 방향 계전 알고리즘 (A Directional Relay Algorithm Using Positive-Sequence Superimposed Quantity for Transmission Line Protection)

  • 이명수;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권4호
    • /
    • pp.226-233
    • /
    • 2003
  • Directional elements are fundamental to protection scheme security and selectivity, performing such critical tasks as supervising distance elements and controlling overcurrent elements. But, conventional operating principles for directional detection based on negative or zero sequence quantify do not satisfy the requirements for improved sensitivity and fast operation under any fault conditions. In this paper, new algorithm for directional elements is proposed. The proposed algorithm use the positive-sequence superimposed voltages and currents in order to be used in all fault conditions. Also, because this algorithm uses a voltage compensation method. it can be well operated under strong source conditions.

개선된 변류기 보상알고리즘을 적용한 모선보호용 비율전류차동 계전방식 (A Percentage Current Differential Relaying Algorithm for Bus Protection Using an Advanced Compensating Algorithm of the CTs)

  • 강용철;윤재성;강상희
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.158-164
    • /
    • 2003
  • This paper proposes a percentage current differential relaying algorithm for bus protection using an advanced compensating algorithm of the secondary current of current transformers (CTs). The compensating algorithm estimates the core flux at the start of the first saturation based on the value of the second-difference of the secondary current. Then, it calculates the core flux and compensates distorted currents using the magnetization curve. The algorithm Is unaffected by a remanent flux. The simulation results indicate that the proposed algorithm can discriminate internal faults from external faults when the CT saturates. This paper concludes by implementing the algorithm into a TMS320C6701 digital signal processor. The results of hardware implementation are also satisfactory. The proposed algorithm can improve not only stability of the relay in the case of an external fault but sensitivity of the relay in the case of an internal fault.

외부 전자파 펄스에 의해 전송선로에 유기되는 과전류 및 과전압 보호회로의 해석 (Analysis of Protection Circuits of Overcurent and Overvoltage on Transmission Line Induced by External Electromagnetic Pulse)

  • 하헌태;김세윤;이경재;오명환
    • 전자공학회논문지A
    • /
    • 제28A권1호
    • /
    • pp.8-14
    • /
    • 1991
  • A new algorithm for calculation of overcurrent and overvoltage at load for parallel two-wire transmission line with nonlinear protection circuits induced by and external electromagnetic pulse is suggested. The rigorous solution is obtained for a particular type of the incident waveform and protection circuit. The validity of our algorithm is checked by comparing numerical results to the analytic solution in the particular case.

  • PDF