• Title/Summary/Keyword: Process energy evaluation

Search Result 694, Processing Time 0.031 seconds

Performance Analysis of Upgrading Process with Amine-Based CO2 Capture Pilot Plant

  • Kwak, No-Sang;Lee, Junghyun;Lee, Dong Woog;Lee, Ji Hyun;Shim, Jae-Goo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 2018
  • This study applied upgrades to the processes of a 10 MW wet amine $CO_2$ capture pilot plant and conducted performance evaluation. The 10 MW $CO_2$ Capture Pilot Plant is a facility that applies 1/50 of the combustion flue gas produced from a 500 MW coal-fired power plant, and is capable of capturing up to 200 tons of $CO_2$. This study aimed to quantitatively measure efficiency improvements of post-combustion $CO_2$ capture facilities resulting from process upgrades to propose reliable data for the first time in Korea. The key components of the process upgrades involve absorber intercooling, lean/rich amine exchanger efficiency improvements, reboiler steam TVR (Thermal Vapor Recompression), and lean amine MVR (Mechanical Vapor Recompression). The components were sequentially applied to test the energy reduction effect of each component. In addition, the performance evaluation was conducted with the absorber $CO_2$ removal efficiency maintained at the performance evaluation standard value proposed by the IEA-GHG ($CO_2$ removal rate: 90%). The absorbent used in the study was the highly efficient KoSol-5 that was developed by KEPCO (Korea Electric Power Corporation). From the performance evaluation results, it was found that the steam consumption (regeneration energy) for the regeneration of the absorbent decreased by $0.38GJ/tonCO_2$ after applying the process upgrades: from $2.93GJ/ton\;CO_2$ to $2.55GJ/tonCO_2$. This study confirmed the excellent performance of the post-combustion wet $CO_2$ capture process developed by KEPCO Research Institute (KEPRI) within KEPCO, and the process upgrades validated in this study are expected to substantially reduce $CO_2$ capture costs when applied in demonstration $CO_2$ capture plants.

Prediction and Evaluation Method of Energy Consumption in Machine Tools (공작기계의 에너지 소비량 평가기법 및 예측기술)

  • Lee, Chan-Hong;Hwang, Jooho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.5
    • /
    • pp.461-466
    • /
    • 2013
  • In this paper, main mechanism and measurement method of energy consumption for machine tools are investigated by experiment and simulation. To evaluate total energy consumption of the machine tools, standard test workpiece and measuring method and test procedures are suggested. And, improvement of energy consumption evaluation by the motion kinematics theory is used. In addition, to estimate energy consumption of machine tools in design process, mass distribution of the structure and 5 axis motions are investigated and simulated by numerical analysis.

A Study on the Evaluation of the Environmental Impact of Energy Usage in Construction Sites (건설현장 내 에너지 사용량에 따른 환경영향 평가에 관한 연구)

  • Lee, Chung-Won;Tae, Sung-Ho;Jang, Hyeong-Jae;Lim, Hyo-Jin;Kim, Hyeon-Suk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.119-120
    • /
    • 2022
  • As the seriousness of the climate crisis is emphasized, movements to solve it are becoming active. In Korea, efforts to reduce environmental impacts across all industries are being strengthened through the Framework Act on Low Carbon Green Growth. The construction industry predicts the environmental impact of buildings during the entire life cycle, but in the construction process, there is a difference in energy usage depending on the amount of input, and it is difficult to predict the environmental impact if data cannot be collected. Therefore, this study evaluated the environmental impact of energy usage in the apartment construction process as part of the study on predicting and reducing the environmental impact of the construction process of the construction site. To this end, the environmental effects of buildings were set as global warming, resource consumption, and ozone layer effects, and the environmental effects of the actual energy use in the case were evaluated. In addition, based on the evaluation results, the characteristics of the input energy usage were compared and analyzed.

  • PDF

Performance Evaluation between Alternating Type Process and Recirculating Type Process by using a Mathematical Model (수학적 모델을 활용한 alternating 형태 공정과 recirculating 형태 공정의 성능 평가)

  • Kim, Hyosoo;Kim, Yejin;Cha, Jaewhan;Choi, Soojung;Min, Kyungjin;Kim, Changwon
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.160-167
    • /
    • 2010
  • In this research, the performance evaluation between an alternating type process and a recirculating type process was investigated by using mathematical models. The Advanced Phase Isolation Ditch (APID) process and the $A^2/O$ process were selected the target processes of the alternating type and recirculating type, respectively. For more quantitative evaluation, 5 performance indexes which included economy and energy efficiency as well as effluent quality were used, and various disturbance conditions of influent were given to the process models. As simulation results, the APID process which had the specific operation modes to use the organic matter in influent effectively showed higher efficiency of denitrification than the $A^2/O$ process. In the case of effluent TSS, the $A^2/O$ process that the retention time in reactors could be maintained stably was more effective than the APID process. In the cases of various disturbance condition, although it was identified that both two processes had similar effluent quality, the sludge production of the $A^2/O$ process showed lower than that of the APID process while the APID process showed higher energy efficiency.

DSM Potential Evaluation and Procedures on Commercial Sector (업무용 부문의 DSM 잠재량 평가절차 및 절전잠재량 추정)

  • Rhee, Chang-Ho;Park, Jong-Jin;Jo, In-Seung
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.531-537
    • /
    • 1999
  • This paper presents the evaluaton procedures and the estimation model for DSM potential on commercial sector in Korea. In general, the evaluation process of the potential savings for DSM measures or programs consists of baseline electricity consumption forecast and potential evaluation such as technical potential(TP), economic potnetial(EP), and achievable potential(AP). A library of energy conservation measures applicable to each end-use or apparatus is developed, and energy savings and other factors are applied to the baseline demand estimates of consumption to produce potential savings estimates. The purpose of this paper is to establish the evaluation process of those DSM potential for commercial sector. In case study, we applied it to commercial sector for horizon years by end-use.

  • PDF

Formulation of Tearing Energy for Fatigue Life Evaluation of Rubber Material (고무의 피로수명 평가를 위한 찢김에너지 정식화)

  • Kim, Heon-Young;Kim, Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.8 s.239
    • /
    • pp.1132-1138
    • /
    • 2005
  • Fatigue life of metal material can be predicted by the use of fracture theory and experimental database. Although prediction of fatigue life of rubber material uses the same way as metal, there are many reasons to make it almost impossible. One of the reasons is that there is not currently used fracture criteria for rubber material beacuse of non-standardization, various way of composition process of rubber and so on. Tearing energy is one of the fracture criteria which can be applied to a rubber. Even if tearing energy relaxes the restriction of rubber composition, it is also not currently used because of complication to apply in. Research material about failure process of rubber and tearing energy was reviewed to define the process of fatigue failure and the applicability of tearing energy in estimation of fatigue life for rubber. Also, 1file element formulation of tearing energy which can be used in FE analysis was developed.

An Evaluation of the National Competitiveness of Hydrogen Energy (AHP를 이용한 수소에너지의 국가경쟁력 평가)

  • Gim, Bong-Jin;Kim, Jong-Wook;Choi, Sang-Jin;Kang, Seok-Hun;Kang, Kwng-Seok
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.4
    • /
    • pp.461-469
    • /
    • 2006
  • This paper deals with the national competitiveness of hydrogen energy. The effectiveness of investments for hydrogen energy R&D and constructions of hydrogen energy infrastructures can be evaluated by the national competitiveness of hydrogen energy, and it is evaluated by an AHP(analytic hierarchy process) method. The evaluation indices of the national competitiveness are selected as the technical level, the number of researchers, the investments for R&D, and the infrastructure of hydrogen energy. Similarly, the technical level is divided into the number of published papers, the number of foreign patents, and the number of published proceeding papers. The evaluation indices of the technical level and the number of researchers were investigated by database searches. It appears that South Korea locates the sixth position in the world. The results of our study suggest that South Korea is relatively competitive in the technical level and the number of researchers. However, our country needs the long-term and well-focused R&D, and the expansion of infrastructures to enhance the national competitiveness of hydrogen energy in the future.

Simulation for the Evaluation of Reforming Parameter Values of the Natural Gas Steam Reforming Process for a Small Scale Hydrogen-Fueling Station (소규모 수소 충전소용 천연가스 수증기 개질공정의 수치모사 및 공정 변수 값의 산정)

  • Lee, Deuk-Ki;Koo, Kee-Young;Seo, Dong-Joo;Seo, Yu-Taek;Roh, Hyun-Seog;Yoon, Wang-Lai
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.18 no.1
    • /
    • pp.12-25
    • /
    • 2007
  • Numerical simulation of the natural gas steam reforming process for on-site hydrogen production in a $H_2$ fueling station was conducted on the basis of process material and heat balances. The effects of reforming parameters on the process efficiency of hydrogen production were investigated, and set-point values of each of the parameters to minimize the sizes of unit process equipments and to secure a stable operability of the reforming process were suggested. S/C ratio of the reforming reactants was found to be a crucial parameter in the reforming process mostly governing both the hydrogen production efficiency and the stable operability of the process. The operation of the process was regarded to be stable if the feed water(WR) as a reforming reactant could evaporate completely to dry steam through HRSG. The optimum S/C ratio was 3.0 where the process efficiency of hydrogen production was maximized and the stable operability of the process was secured. The optimum feed rates of natural gas(NGR) and WR as reforming reactants and natural gas(NGB) as a burner fuel were also determined for the hydrogen production rate of $27\;Nm^3/h$.

A Study on the Evaluation Method for Professional ESCO (전문 ESCO 지정제 평가방안 연구)

  • Lim, Ki Choo
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.90-95
    • /
    • 2013
  • The paper is aimed at evaluation method for technology-focused professional ESCO. We set up some premise about the evaluation indicators, there are such as the financial soundness, energy savings performance excellence, customer satisfaction, source technology vendor's participation, and guaranteed savings contract. The evaluation indicators consist of the evaluation of expertise (40points), management state (15points), customer satisfaction (20points), technical skills (25points), and detailed indicators were determined. We can apply technology categories such as lighting, cogeneration, process improvement, waste heat recovery, cooling & heating equipments.

Safety Analyses of Process and Facility for the ACP Demonstration

  • You, Gil-Sung;Choung, Won-Myung;Ku, Jeong-Hoe;Cho, Il-Je;Kook, Dong-Hak;Lee, Eun-Pyo;Park, Seong-Won
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2005.05a
    • /
    • pp.293-294
    • /
    • 2005
  • The safety analyses and evaluation works on the process and facility for ACP demonstration have been performed. The several safety factors, such as the risk, environmental, radiation, structural, criticality, were analyzed. The analysis results confirmed the reliability of the safety on the ACP process and facility during normal and accident conditions.

  • PDF