Fenoxycarb, pyriproxyfen and methoprene are juvenile hormone mimic insecticide. These insecticides have been widely used for mosquito, fly, scale insects, and Lepidoptera. The purpose of this study was to develop a simultaneous determination procedure of fenoxycarb, pyriproxyfen and methoprene residues in crops using HPLC-UVD/MS. These insecticide residues were extracted with acetone from representative samples of four raw products which comprised brown rice, apple, green pepper, and Chinese cabbage. The extract was diluted with saline water, and then n-hexane/dichloromethane partition was followed to recover these insecticides from the aqueous phase. Florisil column chromatography was additionally employed for final clean up of the extract. The analytes were quantitated by HPLC-UVD/MS, using a $C_{18}$ column. The crops were fortified with each insecticide at 3 levels per crop. Mean recovery ratios were ranged from 80.0 to 104.3% in four representative agricultural commodities. The coefficients of variation were less than 4.8%. Quantitative limit of fenoxycarb, pyriproxyfen, and methoprene was 0.04 mg/kg in crop samples. A HPLC-UVD/MS with selected-ion monitoring was also provided to confirm the suspected residues. The proposed simultaneous analysis method was reproducible and sensitive enough to determine the residues of fenoxycarb, pyriproxyfen and methoprene in the agricultural commodities.
Kim, Eunhye;Hwang, Yon-Jin;Kim, Suhee;Lee, Hyeri;Hong, Soonsung;Park, Kyung-Hun;Kim, Jeong-Han
The Korean Journal of Pesticide Science
/
v.16
no.4
/
pp.343-349
/
2012
Exposure and risk assessments were conducted to evaluate the relative safety of mixing/loading work of indoxacarb between wettable powder (WP) and water dispersible granule (WG). Hand exposure was monitored using cotton gloves while inhalation exposure was measured using personal air monitor. Method validation for the exposure monitoring was established successfully through several experiments. Limit of determination and limit of quantitation were 0.25 and 1 ng, respectively. $R^2$ of calibration curve linearity was more than 0.9999 and reproducibility was 0.7-6. Recovery of indoxacarb from gloves, solid sorbent and glass fiber filter at three different levels was 81.5-108.8%. Trapping efficiency and breakthrough tests gave 981.5-108.8% of recovery. During mixing/loading procedure, hand exposure amount (75 percentile of 30 repetitions) for indoxacarb WP was 6 folds (459.8 mg/kg a.i) than that of WG (81.4 mg/kg a.i). This result indicates that WG has less drift than WP thanks to its granular type of formulation. Inhalation amount was $10^{-8}-10^{-7}%$ of spray mixture prepared and $10^{-4}-10^{-3}%$ of hand exposure. In inhalation case, no significant differences were observed between two formulations. Margin of safety was calculated for risk assessment using male Korean average body weight and acceptable operator exposure level as the important exposure factors. Mixing/loading procedures for both of the formulations were considered to be of least risk because calculated MOS values were more than 1.
The Journal of Korean Society for Radiation Therapy
/
v.17
no.1
/
pp.33-40
/
2005
Purpose : We recently perform the latest radiotheraphy (3D conformal, IMRT,etc.) with the development of 3D CT planning technology. However, in case patients with breast cancer, it is difficult to acquire the CT image with the limitation of CT hole size and tilting of breast immobilization device. The Ewha Breast Device(EBD) was constructed to improve the problem in the treatment of patients with breast cancer and we are intend to introduce the procedure of the EBD construction in this study and compare the EBD with conventional breast device in the view point of usefulness. Materials and Methods : We have constructed the EBD with acryl, analyze the skull size with CT data, consider the skin folder in SCL field and evaluated the EBD usefulness from the view point of set-up reproducibility, dose distribution, skin reaction in comparison with conventional breast device. Results : In the case of patients set-up error analysis, the EBD is superior to conventional device in portal film repetition($\%$) check (80pt.), equal to that in simulation & CT image coincidence check(5pt.). There is no difference between the two systems in dose distribution and skin reaction in SCL field is better the EBD than conventional device. Conclusions : The construction of the EBD enable us to perform the latest radiotheraphy in breast treatments, relieve the pains in simulation, and reduce, the skin reaction. In the future, we expect that modification of the EBD is useful in treating for patients with breast cancer.
The Journal of Korean Society for Radiation Therapy
/
v.15
no.1
/
pp.29-33
/
2003
I. Purpose Brachytherapy is the main component in treatment of patients with uterine cervical cancer. The reproducibility of applicator position in the same patient at repeated treatments was very important for accurate dose delivery. It was aimed to evaluate the change of applicator location between each high dose rate(HDR) brachytherapy insertion in the patients with uterine cervical cancer. II. Materials and Methods From January 1999 to October 2001, total 52 patients were treated with external beam radiotherapy and HDR brachytherapy (Microselectron, Nucletron). During six to seven times of brachytherapy, all patients had three treatment plans. From the orthogonal radiographs, we measured the following variables; height from upper border of pubic bone to os (HPO), distance from sacral promontory to tip of tandem (DST), distance from coccyx to os (DCO), distance from tip of right ovoid to os (DRO), distance from tip of left ovoid to os (DLO), and distance from center of the first tandem source to ovoid (DTO). To evaluate the reproducibility of applicator position, it was calculated the standard deviation of differences between three insertions for the 7 parameters in each patient. III. Results The ranges of standard deviations of interfractional differences for the variables were as follows. 1)HPO : $0{\sim}0.79cm$ 2)DST : $0{\sim}0.9cm$ 3)DCO : $0.06{\sim}0.76cm$ 4)DRO : $0{\sim}0.53cm$ 5)DLO : $0{\sim}0.45cm$ 6) DTO $0{\sim}0.36cm$ IV. Conclusions There was some change in applicator position on repeated implants in our study. But variation of the interfractional differences was minimal; in all parameters, there were less than 1 cm. We are continued to try for reducing the geometric variation between each procedure.
Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
The Journal of Korean Society for Radiation Therapy
/
v.18
no.1
/
pp.1-5
/
2006
Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.
Purpose: In arthroscopic rotator cuff repair, the crucial step is secure fixation of Anchor to bone. However, osteoporosis of the tuberosity is frequently encountered in old patients, and can cause insecure fixation of anchors. The Aim of our study was to introduce a technique for anchor hole augmentation with bone cement when fixation failure of an anchor occurs, and to investigate the outcome. Materials and methods: Among 223 rotator cuff repairs performed between 2005 and 2009, anchor hole augmentation with polymethylmethacrylate was performed in 15 cases (all females; mean age of 65 years: range 49~77). Bone cement was injected into the anchor hole in a thick fluid state and the procedure was repeated to make a pot-like cement mantle. The anchor was inserted into the cement mantle while the cement hardened. The outcome was investigated, on average, at 16 months (6~32). Results: Radiographs showed cystic changes of the tuberosity. On follow-up radiographs and MRI, a change in the cement mantle was not noted. The final average UCLA score was 31 (28~35); 6 had excellent, 8 good and 1 fair results (p=0.008). Age-sex matched Constants score was 90 (74~98) (p=0.008). Conclusion: Anchor hole augmentation with bone cement is useful when fixation failure of an anchor is encountered due to bone atrophy. Anchor hole augmentation with bone cement does not negatively influence the outcome.
Ahn Yong Chan;Cho Byung Chul;Choi Dong Rock;Kim Dae Yong;Huh Seung Jae;Oh Do Hoon;Bae Hoonsik;Yeo In Hwan;Ko Young Eun
Radiation Oncology Journal
/
v.18
no.2
/
pp.150-156
/
2000
Purpose : Stereotactic radiation therapy (SRT) can deliver highly focused radiation to a small and spherical target lesion with very high degree of mechanical accuracy. For non-spherical and large lesions, however, inclusion of the neighboring normal structures within the high dose radiation volume is inevitable in SRT This is to report the beam shaping using the partial closure of the independent jaw in SRT and the verification of dose calculation and the dose display using a home-made soft ware. Materials and Methods : Authors adopted the idea to partially close one or more independent collimator jaw(5) in addition to the circular collimator cones to shield the neighboring normal structures while keeping the target lesion within the radiation beam field at all angles along the arc trajectory. The output factors (OF's) and the tissue-maximum ratios (TMR's) were measured using the micro ion chamber in the water phantom dosimetry system, and were compared with the theoretical calculations. A film dosimetry procedure was peformed to obtain the depth dose profiles at 5 cm, and they were also compared with the theoretical calculations, where the radiation dose would depend on the actual area of irradiation. Authors incorporated this algorithm into the home-made SRT software for the isodose calculation and display, and was tried on an example case with single brain metastasis. The dose-volume histograms (DVH's) of the planning target volume (PTV) and the normal brain derived by the control plan were reciprocally compared with those derived by the plan using the same arc arrangement plus the independent collimator jaw closure. Results : When using 5.0 cm diameter collimator, the measurements of the OF's and the TMR's with one independent jaw set at 30 mm (unblocked), 15.5 mm, 8.6 mm, and 0 mm from th central beam axis showed good correlation to the theoretical calculation within 0.5% and 0.3% error range. The dose profiles at 5 cm depth obtained by the film dosimetry also showed very good correlation to the theoretical calculations. The isodose profiles obtained on the home-made software demonstrated a slightly more conformal dose distribution around the target lesion by using the independent jaw closure, where the DVH's of the PTV were almost equivalent on the two plans, while the DVH's for the normal brain showed that less volume of the normal brain receiving high radiation dose by using this modification than the control plan employing the circular collimator cone only. Conclusions : With the beam shaping modification using the independent jaw closure, authors have realized wider clinical application of SRT with more conformal dose planning. Authors believe that SRT, with beam shaping ideas and efforts, should no longer be limited to the small spherical lesions, but be more widely applied to rather irregularly shaped tumors in the intracranial and the head and neck regions.
Proceedings of the Korean Society of Organic Agriculture Conference
/
2009.12a
/
pp.275-276
/
2009
민간단체들에 의하여 자율적으로 시작된 국내 유기농업은 친환경농업육성법(1997. 12.13)이 제정되면서 국가기관의 친환경농업 활성화 노력과 더불어 2008년 유기농재배 농가(8,460호)와 면적(12,033호)이 급격히 증가되었다. 또한 유기농업의 확산과 더불어 화학비료 및 유기합성 농약대체 친환경농자재들의 유통이 증가되고 있으나 관리규정이 없어 검증되지 않은 다양한 농자재들이 유통되어 친환경실천 농가들의 혼란이 초래되어 국정감사 시 문제점으로 지적과 함께 각계에서 관리제도의 필요성이 대두되었다. 친환경농업육성법 시행령 개정(대통령령 제19964호, 2007.3.27.공포, 2007.3.28.시행)으로 농촌진흥청에 친환경농자재심의회가 설치되어 효과와 효능을 검증하지 아니하고 친환경농산물 중 유기농산물 생을 해 사용가능한 자재인지 여부를 검토하여 그 결과를 공개하는 목록공시제가 마련되었다. 친환경유기농자재 목록공시는 1년에 4회 매분기말에 농촌진흥청 농자재관리과에서 접수를 받아 친환경농자재 분야별 전문위원회 검토 후 심의위원회 심의를 거쳐 접수일로부터 90일 이내에 농촌진흥청장이 공시(농진청 홈페이지, 관보게재)하고 친환경농업 관련기관 및 검토 신청자에게 통보함으로서 마무리된다. 목록 공시된 친환경유기농자재의 유효기간은 2년이다. 친환경농자재심의위원회는 토양개량 및 작물생육분야 전문위원회 위원 11명, 병 해충 관리분야 전문위원회 위원 11명 및 심의위원회 의원 20명으로 구성되어 있다. 2007년 3월부터 2009년 11월 30일 현재 목록 공시된 친환경유기농자재 제품은 (1) 양개량용 자재 25 개, (2) 작물생육용 자재 282개, (3) 토양개량 및 작물생육용 자재 308개, (4) 작물병해 관리용 자재 110개, (5) 작물충해 관리용 자재 : 224개, (6) 작물병해충 관리용 자재 5개 및 (7) 기타 자재 1개 제품으로 총 955개 제품에 이르고 있다. 한편, 공시연장 미신청, 현재 검토기준안에 필요로 하는 추가요청 자료 미제출 및 공시이외의 물질 사용으로 국내유통 중 단속되어 부적합한 판정을 받아 20여 제품이 목록공시가 취소되었다. 앞으로 목록 공시되는 친환경유기농자재는 제품의 주성분 함량 표기, 시용효과 검정방법 선, 제조방법 현장점검, 안전성 검정 등 여러가지 제도보완 및 사후관리 방안이 시급히 마련되어야 할 것으로 사려된다.
Transactions of the Korean Society for Noise and Vibration Engineering
/
v.23
no.8
/
pp.759-769
/
2013
Electronic equipment has been applied to virtually every area associated with commercial, industrial, and military applications. Specifically, electronics have been incorporated into avionics components installed in aircraft. This equipment is exposed to dynamic loads such as vibration, shock, and acceleration. Especially, avionics components installed in a helicopter are subjected to simultaneous sine and random base excitations. These are denoted as sine on random vibrations according to MIL-STD-810F, Method 514.5. In the past, isolators have been applied to avionics components to reduce vibration and shock. However, an isolator applied to an avionics component installed in a helicopter can amplify the vibration magnitude, and damage the chassis, circuit card assembly, and the isolator itself via resonance at low-frequency sinusoidal vibrations. The objective of this study is to investigate the dynamic characteristics of an avionics component installed in a helicopter and the structural dynamic modification of its tray plate without an isolator using both a finite element analysis and experiments. The structure is optimized by dynamic loads that are selected by comparing the vibration, shock, and acceleration loads using vibration and shock response spectra. A finite element model(FEM) was constructed using a simplified geometry and valid element types that reflect the dynamic characteristics. The FEM was verified by an experimental modal analysis. Design parameters were extracted and selected to modify the structural dynamics using topology optimization, and design of experiments(DOE). A prototype of a modified model was constructed and its feasibility was evaluated using an FEM and a performance test.
Today, administrative legislation is becoming more and more important in that it not only sets the legal life relationship of the people in great detail and detail, but is closely related to the occurrence, extinction, and alteration of rights and obligations held by prisoners. In the United States, the types of administrative legislation are divided into substantive and interpretative regulations, so-called substantive regulations, which give prior notice and opportunity to comment on interested parties through formal or informal administrative procedures in accordance with Article 553 of the Federal Administrative Procedures Act. On the other hand, the interpretation regulation, which is "the regulation established by the Administration for the simple interpretation of statutes," does not require prior notice or comment because it does not affect the people's rights obligations. The Azar v. Allina Health Service, 587 U.S. 1804, 2019 ruling by the U.S. Constitutional Court, subject to this research paper, is about a dispute over a new decision to require Medicare to determine the amount of compensation for care providers that provide medical services for the poor, and should the regulations be regarded as substantive under the Administrative Procedures Act and should not be given a hearing or a simple internal process for processing. Given that the current administrative procedure law of our country stipulates the procedures for administrative pre-announcement through Articles 42.1 and 44.1, but that our courts have not judged violations of legislative pre-announcement procedures under the Administrative Procedures Act so far as to judge the illegality of administrative legislation, the dispute of the U.S. Constitutional Court will provide new implications for controlling legal orders beyond simple legal interpretation and has great significance in terms of readjustment of relevant regulations under future administrative procedures.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.