• Title/Summary/Keyword: Probing Accuracy

Search Result 31, Processing Time 0.028 seconds

Development of Calibration and Real-Time Compensation System for Total Measuring Accuracy in a Commercial CMM (상용 3차원 측정기의 전체 측정정밀도 교정 및 실시간 보정시스템)

  • 박희재;김종후
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.9
    • /
    • pp.2358-2367
    • /
    • 1994
  • This paper presents techniques for evaluation and compensation of total measuring errors in a commercial CMM. The probe errors as well as the machine geometric errors are assessed from probing of the mechanical artefacts such as shpere, step, and rings. For the error compensation, the integrated volumetric error equations are considered, including the probe error adn the machine geometric error. The error compensation is performed on the absolute scale coordinate system, in order to overcome the redundant degree of freedom in the CMM with multi-axis probe. A interface box and corresponding software driver are developed for data intercepting/correction between the machine controller and machine, thus the volumetric errors can be compensated in real time with minimum interference to the operating software and hardware of a commercial CMM. The developed system applied to a practical CMM installed on the shop floor, and demonstrated its performance.

Development of Laser Diode Test Device using Feedback Control with Machine Vision (비젼 피드백 제어를 이용한 광통신 Laser Diode Test Device 개발)

  • 유철우;송문상;김재희;박상민;유범상
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1663-1667
    • /
    • 2003
  • This thesis is on tile development of LD(Laser Diode) chip tester and the control system based on graphical programming language(LabVIEW) to control the equipment. The LD chip tester is used to test the optic power and the optic spectrum of the LD Chip. The emitter size of LD chip and the diameter of the receiver(optic fiber) are very small. Therefore, in order to test each chip precisely, this tester needs high accuracy. However each motion part of the tester could not accomplish hish accuracy due to the limit of the mechanical performance. Hence. an image processing with machine vision was carried out in order to compensate for the error. and also a load test was carried out so as to reduce tile impact of load on chip while the probing motion device is working. The obtained results were within ${\pm}$5$\mu\textrm{m}$ error.

  • PDF

Machining Accuracy Improvement by On Machine Part Measurement and Error Compensation (기상측정시스템과 오차보정을 이용한 가공정밀도 향상)

  • 최진필;민병권;이상조
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.12
    • /
    • pp.34-41
    • /
    • 2003
  • This paper suggests a methodology fur improving the machining accuracy by compensating for the machining errors based on on-machine measurement process. Probing errors and machine tool errors included in the measurement data were calibrated or compensated to obtain the actual machining errors. Machine tool errors were modeled in forward and backward directions according to the axis movement direction to consider the effects of backlash errors on the measurement data, and model parameters were determined by measuring a cube array artifact. A rectangular workpiece was machined and then measured with a touch probe as a verification experiment. Machining experiments showed that the machining errors were reduced to within the designated tolerance after compensating for the actual machining errors by modifying the original footpath for the next-step machining.

Error propagation in 2-D self-calibration algorithm (2차원 자가 보정 알고리즘에서의 불확도 전파)

  • 유승봉;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.434-437
    • /
    • 2003
  • Evaluation or the patterning accuracy of e-beam lithography machines requires a high precision inspection system that is capable of measuring the true xy-locations of fiducial marks generated by the e-beam machine under test. Fiducial marks are fabricated on a single photo mask over the entire working area in the form of equally spaced two-dimensional grids. In performing the evaluation, the principles of self-calibration enable to determine the deviations of fiducial marks from their nominal xy-locations precisely, not being affected by the motion errors of the inspection system itself. It is. however, the fact that only repeatable motion errors can be eliminated, while random motion errors encountered in probing the locations of fiducial marks are not removed. Even worse, a random error occurring from the measurement of a single mark propagates and affects in determining locations of other marks, which phenomenon in fact limits the ultimate calibration accuracy of e-beam machines. In this paper, we describe an uncertainty analysis that has been made to investigate how random errors affect the final result of self-calibration of e-beam machines when one uses an optical inspection system equipped with high-resolution microscope objectives and a precision xy-stages. The guide of uncertainty analysis recommended by the International Organization for Standardization is faithfully followed along with necessary sensitivity analysis. The uncertainty analysis reveals that among the dominant components of the patterning accuracy of e-beam lithography, the rotationally symmetrical component is most significantly affected by random errors, whose propagation becomes more severe in a cascading manner as the number of fiducial marks increases

  • PDF

Time Series Prediction of Dynamic Response of a Free-standing Riser using Quadratic Volterra Model (Quadratic Volterra 모델을 이용한 자유지지 라이저의 동적 응답 시계열 예측)

  • Kim, Yooil
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.4
    • /
    • pp.274-282
    • /
    • 2014
  • Time series of the dynamic response of a slender marine structure was predicted using quadratic Volterra series. The wave-structure interaction system was identified using the NARX(Nonlinear Autoregressive with Exogenous Input) technique, and the network parameters were determined through the supervised training with the prepared datasets. The dataset used for the network training was obtained by carrying out the nonlinear finite element analysis on the freely standing riser under random ocean waves of white noise. The nonlinearities involved in the analysis were both large deformation of the structure under consideration and the quadratic term of relative velocity between the water particle and structure in Morison formula. The linear and quadratic frequency response functions of the given system were extracted using the multi-tone harmonic probing method and the time series of response of the structure was predicted using the quadratic Volterra series. In order to check the applicability of the method, the response of structure under the realistic ocean wave environment with given significant wave height and modal period was predicted and compared with the nonlinear time domain simulation results. It turned out that the predicted time series of the response of structure with quadratic Volterra series successfully captures the slowly varying response with reasonably good accuracy. It is expected that the method can be used in predicting the response of the slender offshore structure exposed to the Morison type load without relying on the computationally expensive time domain analysis, especially for the screening purpose.

Improved accuracy in periodontal pocket depth measurement using optical coherence tomography

  • Kim, Sul-Hee;Kang, Se-Ryong;Park, Hee-Jung;Kim, Jun-Min;Yi, Won-Jin;Kim, Tae-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.47 no.1
    • /
    • pp.13-19
    • /
    • 2017
  • Purpose: The purpose of this study was to examine whether periodontal pocket could be satisfactorily visualized by optical coherence tomography (OCT) and to suggest quantitative methods for measuring periodontal pocket depth. Methods: We acquired OCT images of periodontal pockets in a porcine model and determined the actual axial resolution for measuring the exact periodontal pocket depth using a calibration method. Quantitative measurements of periodontal pockets were performed by real axial resolution and compared with the results from manual periodontal probing. Results: The average periodontal pocket depth measured by OCT was $3.10{\pm}0.15mm$, $4.11{\pm}0.17mm$, $5.09{\pm}0.17mm$, and $6.05{\pm}0.21mm$ for each periodontal pocket model, respectively. These values were similar to those obtained by manual periodontal probing. Conclusions: OCT was able to visualize periodontal pockets and show attachment loss. By calculating the calibration factor to determine the accurate axial resolution, quantitative standards for measuring periodontal pocket depth can be established regardless of the position of periodontal pocket in the OCT image.

Efficacy of salivary versus subgingival bacterial sampling for the detection and quantification of periodontal pathogens

  • Lee, Yoonsub;Hong, Yoojin;Kim, Bome;Lee, Dajung;Kim, Sungtae;Rhyu, In-chul
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.6
    • /
    • pp.358-367
    • /
    • 2020
  • Purpose: The aim of this study was to investigate the efficacy and validity of subgingival bacterial sampling using a retraction cord, and to evaluate how well this sampling method reflected changes in periodontal conditions after periodontal therapy. Methods: Based on clinical examinations, 87 subjects were divided into a healthy group (n=40) and a periodontitis group (n=47). Clinical measurements were obtained from all subjects including periodontal probing depth (PD), bleeding on probing (BOP), clinical attachment loss (CAL), and the plaque index. Saliva and gingival crevicular fluid (GCF) as a subgingival bacterial sample were sampled before and 3 months after periodontal therapy. The salivary and subgingival bacterial samples were analyzed by reverse-transcription polymerase chain reaction to quantify the following 11 periodontal pathogens: Aggregatibacter actinomycetemcomitans (Aa), Porphyromonas gingivalis (Pg), Tannerella forsythus (Tf), Treponema denticola (Td), Prevotella intermedia (Pi), Fusobacterium nucleatum (Fn), Pavimonas micra (Pm), Campylobacter rectus (Cr), Prevotella nigrescens (Pn), Eikenella corrodens (Ec), and Eubacterium nodatum (En). Results: Non-surgical periodontal therapy resulted in significant decreases in PD (P<0.01), CAL (P<0.01), and BOP (P<0.05) after 3 months. Four species (Pg, Tf, Pi, and Pm) were significantly more abundant in both types of samples in the periodontitis group than in the healthy group. After periodontal therapy, Cr was the only bacterium that showed a statistically significant decrease in saliva, whereas statistically significant decreases in Cr, Pg, and Pn were found in GCF. Conclusions: Salivary and subgingival bacterial sampling with a gingival retraction cord were found to be equivalent in terms of their accuracy for differentiating periodontitis, but GCF reflected changes in bacterial abundance after periodontal therapy more sensitively than saliva.

NAC Measurement Technique on High Parallelism Probe Card with Protection Resistors

  • Kim, Gyu-Yeol;Nah, Wansoo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.641-649
    • /
    • 2016
  • In this paper, a novel time-domain measurement technique on a high parallelism probe card with protection resistors installed is proposed. The measured signal amplitude decreases when the measurement is performed by Needle Auto Calibration (NAC) probing on a high parallelism probe card with installed resistors. Therefore, the original signals must be carefully reconstructed, and the compensation coefficient, which is related to the number of channel branches and the value of protection resistors, must be introduced. The accuracy of the reconstructed signals is analyzed based on the varying number of channel branches and various protection resistances. The results demonstrate that the proposed technique is appropriate for evaluating the overall signal performance of probe cards with Automatic Test Equipment (ATE), which enhances the efficiency of probe card performance test dramatically.

Measurement of In- plane Displacement by Speckle Photography and Image Processing (스펙클 포토그라피와 화상처리(畵像處理)에 의(依)한 면내변위(面內變位) 계측(計測))

  • Han, Eung-Kyo;Sumi, Seinosuke;Kim, Koung-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.6 no.2
    • /
    • pp.37-45
    • /
    • 1987
  • Speckle photography is a very useful method for measuring in-plane surface displacement. In its basic form, the object to be studied is illuminated with a divergent laser beam, and a double exposure photograph of the object is recorded, on a fine-grain film or plate, before and after the object is deformed, The magnitude and the direction of the displacement can then be obtained by measuring the spacing and the direction of the Young's fringe, which is produced by probing the developed negative with an unexpaned laser beam, and consists of a pattern of parallel equi-spaced dark bands. In this paper, a hybrid optical and electronic image processing is described-Young's fringe on the viewing screen is observed by a TV-camera and the 2-D video signal is converted from analog to digital and transfered to the computer where the spacing and direction of the fringes are calculated. Several examples of application show that the displacement magnitude and direction can be determined with an accuracy of $0.1{\mu}m\;and\;0.1^{\circ}$ respectively.

  • PDF

Power Integrity and Shielding Effectiveness Modeling of Grid Structured Interconnects on PCBs

  • Kwak, Sang-Keun;Jo, Young-Sic;Jo, Jeong-Min;Kim, So-Young
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.3
    • /
    • pp.320-330
    • /
    • 2012
  • In this paper, we investigate the power integrity of grid structures for power and ground distribution on printed circuit board (PCB). We propose the 2D transmission line method (TLM)-based model for efficient frequency-dependent impedance characterization and PCB-package-integrated circuit (IC) co-simulation. The model includes an equivalent circuit model of fringing capacitance and probing ports. The accuracy of the proposed grid model is verified with test structure measurements and 3D electromagnetic (EM) simulations. If the grid structures replace the plane structures in PCBs, they should provide effective shielding of the electromagnetic interference in mobile systems. An analytical model to predict the shielding effectiveness (SE) of the grid structures is proposed and verified with EM simulations.