• 제목/요약/키워드: Probe measurements

검색결과 399건 처리시간 0.026초

고속 3차원 측정 및 칼라 이미징을 위한 다중 광탐침 공초점 주사 현미경 (Confocal Scanning Microscopy with Multiple Optical Probes for High Speed 3D Measurements and Color Imaging)

  • 천완희;이승우;안진우;권대갑
    • 반도체디스플레이기술학회지
    • /
    • 제7권1호
    • /
    • pp.11-16
    • /
    • 2008
  • Confocal scanning microscopy is a widely used technique for three dimensional measurements because it is characterized by high resolution, high SNR and depth discrimination. Generally an image is generated by moving one optical probe that satisfies the confocal condition on the specimen. Measurement speed is limited by movement speed of the optical probe; scanning speed. To improve measurement speed we increase the number of optical probes. Specimen region to scan is divided by optical probes. Multi-point information each optical probe points to can be obtained simultaneously. Therefore image acquisition speed is increased in proportion to the number of optical probes. And multiple optical probes from red, green and blue laser sources can be used for color imaging and image quality, i.e., contrast, is improved by adding color information by this way. To conclude, this technique contributes to the improvement of measurement speed and image quality.

  • PDF

모발의 나노 트라이볼러지 특성해명을 위한 원자현미경(Atomic Force Microscopy) 프로브의 개발 (A New Design of AFM Probe for Nanotribological Characterizations Measurement of Human Hair)

  • 권현규;고언위
    • 반도체디스플레이기술학회지
    • /
    • 제14권4호
    • /
    • pp.1-7
    • /
    • 2015
  • People are always pursuing the aesthetic feeling relentlessly. But some people have such problems with their hairs like alopecia, cancer chemotherapy, burns, and scalp injury. So the synthetic hair has played a very important role to make up for these deficiencies. But long term use can lead to adverse reactions or uncomfortable feeling. This is primarily caused by its properties differ with human hair. In particular, nanotribological characterizations (roughness, friction force and adhesive force) of synthetic hair surface are dissatisfy with the needs of normal hairs. This paper presents the experiments on nanotribological characterizations measurements of human hairs (coloring hair, permed hair and common hair) in shampooing condition or without shampooing condition. Using atomic force microscopy (AFM) to find out a range of synthetic hair nanotribological characterizations which can correspond with natural hair. The measurements of nanotribological characterizations focus on surface roughness, friction force and adhesive force, and a new design of AFM probe was used for measuring the nanotribological characterizations.

Langmuir probe measurements of electron density and electron temperature in early stage of laser-produced carbon plasma

  • Hong, C.;Chae, H.B.;Lee, S.B.;Han, Y.J.;Jung, J.H.;Cho, B.K.;Park, H.;Kim, C.K.;Kim, S.O.
    • Transactions on Electrical and Electronic Materials
    • /
    • 제1권1호
    • /
    • pp.32-39
    • /
    • 2000
  • Langmuir probe measurements of electron density, electron temperature and potential are mad in the early stage (<5${\mu}$s) of a laser ablated plasma plume, in which a positive current form positive ions and a electron current are overlapped. The plasma wes produced by focusing the second harmonic, 532 nm, of Q-switched Nd:YAG laser on a high purity carbon target. Then the laser intensity on the target of ~1.6${\times}$10$\^$15/ W/$\textrm{cm}^2$. The measured electron desities and temperatures are ~2${\times}$10/sip 11/ cm$\^$-3/ and -3 eV. In particluar , the phenomenon that the electron temperature decreased and then increased was observed,. It could be well explained that this phenomenon occurred in the process of inverse Bremsstrahlung of free electrons in plasma. Additionally, the plasma potential(>11V) was higher than the published values.

  • PDF

The Vortical Flow Field of Delta Wing with Leading Edge Extension

  • Lee, Ki-Young;Sohn, Myong-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제17권6호
    • /
    • pp.914-924
    • /
    • 2003
  • The interaction and breakdown of vortices over the Leading Edge Extension (LEX) - Delta wing configuration has been investigated through wing-surface pressure measurements, the off-surface flow visualization, and 5-hole probe measurements of the wing wake section. The description focused on analyzing the interaction and the breakdown of vortices depending on the angle of attack and the sideslip angle. The Effect of angle of attack and sideslip angle on the aerodynamic load characteristics of the model is also presented. The sideslip angle was found to be a very influential parameter of the vortex flow over the LEX-delta wing configuration. The introduction of LEX vortex stabilized the vortex flow, and delayed the vortex breakdown up to a higher angle of attack. The vortex interaction and breakdown was promoted on the windward side, whereas it was suppressed on the leeward side.

Characterization of Two-Dimensional Transition Metal Dichalcogenides in the Scanning Electron Microscope Using Energy Dispersive X-ray Spectrometry, Electron Backscatter Diffraction, and Atomic Force Microscopy

  • Lang, Christian;Hiscock, Matthew;Larsen, Kim;Moffat, Jonathan;Sundaram, Ravi
    • Applied Microscopy
    • /
    • 제45권3호
    • /
    • pp.131-134
    • /
    • 2015
  • Here we show how by processing energy dispersive X-ray spectrometry (EDS) data obtained using highly sensitive, new generation EDS detectors in the AZtec LayerProbe software we can obtain data of sufficiently high quality to non-destructively measure the number of layers in two-dimensional (2D) $MoS_2$ and $MoS_2/WSe_2$ and thereby enable the characterization of working devices based on 2D materials. We compare the thickness measurements with EDS to results from atomic force microscopy measurements. We also show how we can use electron backscatter diffraction (EBSD) to address fabrication challenges of 2D materials. Results from EBSD analysis of individual flakes of exfoliated $MoS_2$ obtained using the Nordlys Nano detector are shown to aid a better understanding of the exfoliation process which is still widely used to produce 2D materials for research purposes.

Effects of Position of Auxiliary Probe on Ground Resistance Measurement Using Fall-of-Potential Method

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • 제7권2호
    • /
    • pp.1-6
    • /
    • 2008
  • In this paper, the effects of the position and the angle of the potential probes on the measurements of the ground resistance using the fall-of-potential method are described and the testing techniques for minimizing the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the relative error in the measured value of the ground resistance due to the position of the potential probe, the ground resistance was measured for the case in which the distance of the current probe was fixed at 50[m] and the distance of the potential probe was located from 10[m] to 50[m]. Also, the potential probe was located in turn at $30[^{\circ}]$, $45[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$, and $180[^{\circ}]$. As a consequence, relative error decreased with increasing distance of the potential probe and decreasing angle between the current probe and potential probe. The results could help to determine the position of the potential probe during the ground resistance measurement.

전위보조전극의 위치변화에 따른 접지저항 측정값의 상대오차분석 (Relative Error Analysis for Measuring Value of Ground Resistance according to Position Variation of Potential Probe))

  • 길형준;김동우
    • 조명전기설비학회논문지
    • /
    • 제23권2호
    • /
    • pp.96-102
    • /
    • 2009
  • 본 논문에서는 전위강하법을 이용한 접지저항 측정시 전위보조전극의 위치 및 각도의 영향에 대하여 기술하였으며, 측정시 오차를 최소화하는 기법을 제안하였다. 전위강하법은 이론적으로 전위와 전류의 측정원리에 근간을 두고 있으며 측정오차는 주로 보조전극의 위치와 각도에 기인한다. 전위보조전각의 위치에 의한 접지저항 측정값의 상대오차를 분석하기 위해 전류보조전극의 거리를 50[m]로 고정시키고 전위보조전극의 거리를 10[m]에서 50[m]까지 변화시키며 접지저항을 측정하였고 또한 전위보조전극과 전류보조전극 사이의 각도를 30[$^{\circ}$], 45[$^{\circ}$], 60[$^{\circ}$], 90[$^{\circ}$], 180[$^{\circ}$]로 변화시키며 측정하였다. 결과적으로 전위보조전극의 거리 증가 및 전류보조전극과 전위보조전극 사이의 각도가 감소할수록 상대오차가 작게 나타났다. 본 실험결과는 접지시스템의 접지저항을 측정할 때 전위보조전극의 위치를 결정하는데 활용될 수 있다.

초음파에 의한 콘크리트의 균열깊이 측정에 있어서 음파모드에 관한 연구 (A Study on the Wave Modes in Measurements of the Crack Depth of Concrete by Ultrasonic Waves)

  • 한응교;어세형;김재열
    • 비파괴검사학회지
    • /
    • 제9권1호
    • /
    • pp.39-47
    • /
    • 1989
  • As the necessity of the safety diagnosis of the concrete structure, more reliable ultrasonic technique to qualify the concrete is required. In this study, the artificial surface crack depth is measured using several types of the ultrasonic probes. As results, the horizontal shear wave probe is most useful to determine the crack depth compared to the other probes. For the surface wave probe, the ultrasonic wave path is changed with the surface crack depth.

  • PDF

2차원 Coanda 노즐 제트 의 특성 에 관한 실험적 연구 (Experimental Study of the Characteristics of 2-Dimensional Coanda Nozzle Jet)

  • 이동호;정명균;김응태
    • 대한기계학회논문집
    • /
    • 제6권3호
    • /
    • pp.222-231
    • /
    • 1982
  • A single free jet formed by the interaction of two curved wall jets on a Cylinder surface is defined as "the Coanda nozzle jet" in this study. In order to investigate the characteristics of Coanda nozzle jet, an experimental analysis was carried out; measurements of the static pressure distribution on the cylinder surface, the mean velocity profile, the turbulence intensity, and the Reynolds shear stress by using x-type hot-wire probe.ire probe.

기상측정(機上測定) 시스템 개발 (Development of On-the-Machine Measurement(OMM) System)

  • 이승우;김선호
    • 산업공학
    • /
    • 제11권1호
    • /
    • pp.199-205
    • /
    • 1998
  • This paper describes the development of on-the-machine measuring(OMM) system which can directly measure the two and three dimensional machined accuracy using a scanning probe in milling machine. Two algorithms, NC program based continuous path(CP) measurement and CAD data assisted point to point(PTP) measurement, are developed for three dimensional measurements, with consideration of the characteristics of the scanning probe. The algorithms are used to develop an auto measuring system. The delveloped system is compared with the CMM (Coordinate Measuring Machine) in terms of accuracy and repeatability. The OMM system is expected to realize measurement time reduction and hence result in high productivity.

  • PDF