• Title/Summary/Keyword: Probe measurements

Search Result 399, Processing Time 0.029 seconds

Development of Basic Techniques for Ultrasound-guided Follicular Aspiration I. Measurement of Size of Ovaries, Follicles and Corpora Lutea of Korean Native Cows by Ultrasonography (초음파유도 난포란 채취를 위한 기본 기술의 개발 I. 초음파상에 나타난 한우 난소, 난포 및 황체의 크기 측정)

  • 최민철;강태영;조성근;최상용;손우진;이효종
    • Journal of Embryo Transfer
    • /
    • v.12 no.2
    • /
    • pp.203-209
    • /
    • 1997
  • This study was carried out to compare the actual size(length and height) of ovaries, follicles and corpora lutea of Korean native cow with those on sonograms. We used 3 different probes(3.5 MHz abdominal probe, 6.5 MHz transvaginal probe and 5.0 MHz transrectal probe) and a calipher for measurements of ovaries, follicles and corpora lutea on sonograms and actual size. Under water immersion, 157 ovaries were scanned with 3 probes and measured in actual size and compared each other. The average height and width of ovaries of Korean native cows were 17.40$\pm$3.99 and 34.23$\pm$6.02mm, respectively. In comparison of height, length of ovaries and preovulation follicles, we found that image with a transvaginal probe was nearly the same as the actual size(p<0.01), but with an abdominal probe the image was appeared larger than the actual size. In measurement(diameter) of preovulation follicles the transvaginal probe was proven to be more accurate to the actual size than other probes and in corpus luteum measurement all probes were accurate. In the comparison of number of follicles by different size ranges, there was no statistical difference in the count of follicles over 10 mm in diameter between the transvaginal probe and naked eyes.

  • PDF

High-speed Performance of Single Flux Quantum Circuits Test Probe (단자속 양자 회로 측정용 고속 프로브의 성능 시험)

  • 김상문;최종현;김영환;강준희;윤기현;최인훈
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.74-79
    • /
    • 2002
  • High-speed probe made to test single flux quantum(SFQ) circuits was comprised of semi-rigid coaxial cables and microstrip lines. The impedance was set at 50 $\Omega$to carry high-speed signals without much loss. To do performance test of high-speed probe, we have attempted to fabricate a test chip which has a coplanar waveguide(CPW) structure. Electromagnetic simulation was done to optimize the dimension of CPW so that the CPW structure has an impedance of 50$\Omega$, matching in impedance with the probe. We also used the simulation to investigate the effect of the width of signal line and the gap between signal line and ground plane to the characteristics of CPW structure. We fabricated the CPW structure with a gold film deposited on Si wafer whose resistivity was above $1.5\times$10$_4$$\Omega$.cm. The magnitudes of S/sub 21/ of CPW at 6 ㎓ in simulations and in the actual measurements done with a network analyzer were: -0.1 ㏈ and -0.33 ㏈ (type A),-0.2 ㏈ and -0.48 ㏈ (type B), respectively. Using the test chip, we have successfully tested the performance of high-speed probe made for SFQ circuits. The probe showed the good performance overthe bandwidth of 10 ㎓.

  • PDF

Objectively Predicting Ultimate Quality of Post-Rigor Pork Musculature: I. Initial Comparison of Techniques

  • Joo, S.T.;Kauffman, R.G.;Warner, R.D.;Borggaard, C.;Stevenson-Barry, J.M.;Lee, S.;Park, G.B.;Kim, B.C.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.1
    • /
    • pp.68-76
    • /
    • 2000
  • A total of 290 pork loins were selected to include a wide variation of quality to investigate the quality categories into which most pork falls, selection criteria for these categories and methods to objectively assess ultimate pork quality. They were probed at 24 h postmortem (PM) for the following: A) light reflectance by Danish Meat Quality Marbling (MQM), Hennessy Grading Probe (HGP) and Sensoptic Invasive Probe (SIP); B) electrical properties by NWK LT-K21 conductivity (NLT) and Sensoptic Resistance Probe (SRP): and C) pH by NWK pH-K21 (NpH). Also, measurements of % drip loss (PDL) and filter paper wetness (FPW), color brightness (L*), ultimate pH (pHu), lipid content, subjective color (SC), firmness/wetness (SF) and marbling scores (SM) were assessed. Each loin was categorized as either pale, soft and exudative (PSE), reddish-pink, soft and exudative (RSE), reddish-pink, firm and non-exudative (RFN) or dark, firm and dry (DFD). Statistically comparing coefficients of determination (CD), the results indicated that overall, the HGP predicted quality groups slightly better than MQM (CD=71 and 62% respectively), NpH and SRP were less effective (CD= 56 and 44% respectively), and SIP and NLT had the lowest values (CD=36 and 5% respectively). Combining various independent variable did not greatly improve the variation accounted for. When the data was sorted into marbling groups based on lipid content, this was not accurately predicted by any of the probe measurements. The MQM probe remained the best predictor for marbling class and accounted for about 25% of the lipid content variation. This was slightly improved to 33% when pHu was combined with MQM.

Two-dimensional measurements of the ELM filament using a multi-channel electrical probe array with high time resolution at the far SOL region in the KSTAR

  • Hong, Young-Hun;Kim, Kwan-Yong;Kim, Ju-Ho;Son, Soo-Hyun;Lee, Hyung-Ho;Eo, Hyun-Dong;Kim, Min-Seok;Hong, Suk-Ho;Chung, Chin-Wook
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3717-3723
    • /
    • 2022
  • For the first time, two-dimensional temporal behavior of the edge localized mode (ELM) filament is measured in the edge tokamak plasma with a multi-channel electrical probe array (MCEP). MCEP, which has 16 floating probes (4 × 4), is mounted at the far scrape-off layer (SOL) region in the KSTAR. An electron temperature and an ion flux are measured by sideband method (SBM), which can achieve two-dimensional measurements with high time resolution. Furthermore, temporal evolutions of the electron temperature and the ion flux are obtained during the ELM occurrence. In the H-mode period, short spikes from ELM bursts are observed in measured plasma parameters, and the trend is similar to that of typical Hα signal. Interestingly, when blob-like ELM filaments crash the probe, the heat flux is significantly higher in a local region of the probe array. The results show that our probe array using the SBM can measure the ELM behavior and the plasma parameters without the effect of the stray current caused by the huge device. This study can provide valuable data needed to understand the interaction between the SOL plasma and the plasma facing components (PFCs).

Measurement and Analysis of the Flux Profiles of the Coated Conductors using Magneto-optical Image and Scanning Hall Probe (Coated conductor에서 magneto-optical image와 scanning hall probe를 이용한 flux profile의 측정 및 분석)

  • Lee, H.Y.;Kwak, K.S.;Rhyee, J.K.;Yoo, J.;Youm, D.
    • Progress in Superconductivity
    • /
    • v.11 no.2
    • /
    • pp.128-134
    • /
    • 2010
  • The magnetic flux profiles in SmBCO and YBCO coated conductors(CC) in the presence of the external field were comparatively investigated by magneto-optic image and scanning hall probe measurements. The current distributions calculated by using the inversion method from measured field profiles show that the decrease of current densities near the edges of SmBCO CC is more significant than those of YBCO CC. Through the comparison of the numerical analysis based on Kim's critical state model and the Brandt and Indenbom's solution, we found that this feature is related to their different field dependant properties of the critical current densities.

Understanding of RF Impedance Matching System Using VI-Probe

  • Lee, Ji Ha;Park, Hyun Keun;Lee, Jungsoo;Hong, Snag Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.3
    • /
    • pp.43-48
    • /
    • 2020
  • The demand for stable plasma has been on the rise because of the increased delivery power amount in the chamber for improving productivity, and fast and accurate plasma impedance matching become a crucial performance measure for radio frequency (RF) power system in semiconductor manufacturing equipment. In this paper, the overall impedance matching was understood, and voltage and current values were extracted with voltage - current (VI) probe to measure plasma impedance in real-time. Actual matching data were analyzed to derive calibration coefficient for V and I measurements to understand the characteristics of VI probe, and we demonstrated the tendency of RF impedance matching according to changes in load impedance. This preliminary empirical research can contribute to fast RF matching as well as advanced equipment control for the next level of detailed investigation on embedded system based-RF matching controller.

Simulation of a Langmuir Probe in an ECR Reactor (ECR Reactor 내의 Langmuir Probe 시뮬레이션)

  • Kim, Hoon;Porteous, Robert K.;Boswell, Rod W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1609-1611
    • /
    • 1994
  • In ECR and helicon reactors for plasma processing, a high density plasma is generated in a source region which is connected to a diffusion region where the processing takes place. Large density and potential gradients can develop at the orifice of the source which drive ion currents into the diffusion region. The average ion velocity may become the order of the sound velocity. Measurements of the ion saturation current to a Langmuir probe are used as a standard method of determining the plasma density in laboratory discharges. However, the analysis becomes difficult in a steaming plasma. We have used the HAMLET plasma simulator to simulate the ion flow to a large langmuir probe in an ECR plasma. The collection surface was aligned with the Held upstream, normal to the field, and downstream. ion trajectories through the electric and magnetic fields were calculated including ion-neutral collisions. We examines the ratio of ion current density to plasma density as a function of magnetic field and pressure.

  • PDF

Observation of the Vortex Interaction over an Yawed Delta Wing with Leading Edge Extension by Flow Visualization and 5-hole Probe Measurements (가시화와 5공 프로브 측정을 통한 연장된 앞전을 갖는 편요된 델타형 날개에서의 와류 상호작용 관찰)

  • Sohn, Myong-Hwan;Lee, Ki-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.388-393
    • /
    • 2001
  • An experimental study is conducted to investigate the interaction of vortices over a delta wing with leading edge extension(LEX) through the off-surface flow visualization and the 5-hole probe measurements of the wing wake region. Especially, the application of a new visualization technique is employed by ultrasonic humidifier water droplet and laser beam sheet. The results, both the off-surface visualization and the 5-hole probe, show that LEX tends to stabilize the vortices of the delta wing up to the high angle of attack even though the model is yawed. With increasing yaw, the windward leading edge vortex moves inward, and closer to the wing surface, while the leeward vortex moves outwards and away from the wing surface. The vortex interaction is promoted in the windward side, and is delayed in the leeward side.

  • PDF

A Comparative study on the palatal mucosa thickness measurements using periodontal probe and pltrasonic device (치주탐침과 초음파기구를 이용한 구개 점막 두께 측정치의 비교연구)

  • Kim, Tae-Woo;Lee, Jae-Kwan;Um, Heung-Sik;Chang, Beom-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.4
    • /
    • pp.901-911
    • /
    • 2006
  • Maxillary palatal mucosa is the most frequently used donor site of the soft tissue for periodontal plastic surgery. In our study, thickness of the palatal mucosa between the mesial side of the maxillary first premolars and the distal side of the maxillary first molars was measured with a periodontal probe and an ultrasonic device in 30 young Korean adults. Using the data, the possibility of the clinical application of ultrasonic devices was evaluated. The results of this study were as follow; 1. The thickness of the palatal mucosa of the maxillary premolars is the thickest and that of the mid-palatal portion of the maxillary first molar is the thinnest. 2. The thickness of the palatal mucosal tissue increases from the gingival margin to the mid-palatal suture. 3. The measurements of the periodontal probe and the ultrasonic device revealed the strong positive correlations.