• Title/Summary/Keyword: Probe current

Search Result 568, Processing Time 0.022 seconds

Comparison of Digital PCR and Quantitative PCR with Various SARS-CoV-2 Primer-Probe Sets

  • Park, Changwoo;Lee, Jina;Hassan, Zohaib ul;Ku, Keun Bon;Kim, Seong-Jun;Kim, Hong Gi;Park, Edmond Changkyun;Park, Gun-Soo;Park, Daeui;Baek, Seung-Hwa;Park, Dongju;Lee, Jihye;Jeon, Sangeun;Kim, Seungtaek;Lee, Chang-Seop;Yoo, Hee Min;Kim, Seil
    • Journal of Microbiology and Biotechnology
    • /
    • v.31 no.3
    • /
    • pp.358-367
    • /
    • 2021
  • The World Health Organization (WHO) has declared the coronavirus disease 2019 (COVID-19) as an international health emergency. Current diagnostic tests are based on the reverse transcription-quantitative polymerase chain reaction (RT-qPCR) method, which is the gold standard test that involves the amplification of viral RNA. However, the RT-qPCR assay has limitations in terms of sensitivity and quantification. In this study, we tested both qPCR and droplet digital PCR (ddPCR) to detect low amounts of viral RNA. The cycle threshold (CT) of the viral RNA by RT-PCR significantly varied according to the sequences of the primer and probe sets with in vitro transcript (IVT) RNA or viral RNA as templates, whereas the copy number of the viral RNA by ddPCR was effectively quantified with IVT RNA, cultured viral RNA, and RNA from clinical samples. Furthermore, the clinical samples were assayed via both methods, and the sensitivity of the ddPCR was determined to be equal to or more than that of the RT-qPCR. However, the ddPCR assay is more suitable for determining the copy number of reference materials. These findings suggest that the qPCR assay with the ddPCR defined reference materials could be used as a highly sensitive and compatible diagnostic method for viral RNA detection.

Effect of Attention Feedback Awareness and Control Training on Attention Bias and Generalized Anxiety Symptoms in college students (주의 피드백 인식 및 조절 훈련이 대학생의 주의편향 및 범불안에 미치는 효과)

  • Kim, Su Jung;Shim, Eun-Jung
    • Korean Journal of School Psychology
    • /
    • v.16 no.2
    • /
    • pp.207-230
    • /
    • 2019
  • This study examined the effect of Attention Feedback Awareness and Control Training(A-FACT) on attention bias and generalized anxiety symptoms in college students. A total of 31 college students with at least 10 points on the Generalized Anxiety Disorder 7-item (GAD-7) scale or at least 56 points on the Korean version of the Penn State Worry Questionnaire (K-PSWQ) with attention bias were randomly assigned to one of three groups: A-FACT( n = 11), Attention Bias Modification (ABM)(n = 10) and Active Placebo Control (APC)(n = 10). Participants in A-FACT group received real-time feedback on attention bias based on their Baseline Neutral Response time(BNR) during A-FACT using a dot probe task. Participants in the ABM group received standard ABM, and those in the APC performed a dot probe task that they were informed was a program to reduce attention bias, but feedback was not provided. A total of eight sessions was conducted twice a week over a 4-week period. After every two sessions, GAD-7, K-PSWQ and K-STAI were rated. The effect of attention bias modification training was rated by changes in the Attention Bias Score(ABS), and in GAD-7, K-PSWQ and K-STAI scores. The results of repeated measure ANOVA indicated that the A-FACT group showed a significant decrease in ABS as well as in GAD-7, K-PSWQ and K-STAI scores compared to the other groups. Current results suggest that self-regulatory control of attention, that is, recognition of bias through feedback in A-FACT, may be effective in alleviating attention bias and generalized anxiety symptoms by recognizing bias through feedback on bias in attention bias modification training.

Quantitative EC Signal Analysis on the Axial Notch Cracks of the SG Tubes (SG Tube 축방향 노치 균열의 정량적 EC 신호평가)

  • Min, Kyong-Mahn;Park, Jung-Am;Shin, Ki-Seok;Kim, In-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.4
    • /
    • pp.374-382
    • /
    • 2009
  • Steam generator(SG) tube, as a barrier isolating primary to the secondary coolant system of nuclear power plants(NPP), must maintain the structural integrity far the public safety and its efficient power generation capacity. And SG tubes bearing defects must be timely detected and taken repair measures if needed. For the accomplishment of these objectives, SG tubes have been periodically examined by eddy current testing(ECT) on the basis of administrative notices and intensified SG management program(SGMP). Stress corrosion cracking(SCC) on the SG tubes is not easily detected and even missed since it has lower signal amplitude and other disturbing factors against its detection. However once SCC is developed, that can cause detrimental affects to the SG tubes due to its rapid propagation rate. Accordingly SCC is categorized as prime damage mechanism challenging the soundness of the SG tubes. In this study, reproduced EDM notch specimens are examined for the detectability and quantitative characterization of the axial ODSCC by +PT MRPC probe, containing pancake, +PT and shielded pancake coils apart in a single plane around the circumference. The results of this study are assumed to be applicable fur providing key information of engineering evaluation of SCC and improvement of confidence level of ECT on SG tubes.

Nondestructive Examination of Ferromagnetic Tube Using Magnetic Saturation Eddy Current Technique (자기포화 와전류기법에 의한 자성 튜브 비파괴검사)

  • Lee, Hee-Jong;Cho, Chan-Hee;Song, Seok-Yoon;Jee, Dong-Hyun;Jung, Jee-Hong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.5
    • /
    • pp.407-415
    • /
    • 2008
  • The tubes in heat exchanger are typically made from copper alloy, stainless steel, carbon steel, titanium alloy material. type-439 ferritic stainless steel is ferromagnetic material, and furnish higher heat transfer rates than austenitic stainless steels and higher resistance to corrosion-induced flaws. Ferritic stainless steel can typically be found in low-pressure(LP) feedwater heaters and moisture separator reheaters(MSRs). LP feedwater heaters generally utilize thin wall type-439 stainless steel tubing, whereas MSRs typically employ a heavier wall tubing with integral fins. Service-induced damage can occur on the OD(outside diameter) surface of type-439 ferritic stainless steel tubing which is employed for MSRs tubing, and the most typical damage mechanism is vibration-induced tube-to-TSP(tube support plate) wear and fatigue cracking. The wear has been reported that occurs mainly on the OD surface. Accordingly, in this study, we have evaluated the flaw sizing capability of magnetic saturation eddy current technique using magnetic saturation probe and flawed specimen.

The Effect of Transcutaneous Electrical Nerve Stimulation on Acute Pain and Beta-Endorphins of Needle Biopsy (경피신경전기자극이 전립선 침생검 조직검사 시 통증과 혈장 베타 엔돌핀 농도에 미치는 효과)

  • Lee, Ji-Min;Hong, Hae-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.15 no.3
    • /
    • pp.99-106
    • /
    • 2013
  • Purpose: The purpose of this study was to examine the effect on plasma beta endorphin concentration level and the influences on pain score of transcutaneous electrical nerve stimulation (TENS) mediation to patients During a prostate needle biopsy. Methods: TENS was administered to only the experimental group. The electric current was given in high frequency (40-100 pps) and low intensity ($2-50{\mu}s$) from the waiting room stage until the end of the procedure. The average time spent was 35 minutes. Following 10 minutes of retention in the rectum, there was a biopsy. In two groups, the pain score was assessed twice when vas pain penetrated into the rectum, during the needle biopsy. The Beta endorphin concentration level was assessed through blood gathering 2 times in the Nuclear Medicine Labs before and after the test. Results: There was not much difference in pain levels from both groups when a microscope probe penetrated into the rectum and in the time when tissues were collected. However, the average overall pain level was reduced during those two procedures. The plasma beta endorphin level was increased in the TENS medicated group compared with the unmedicated group after the procedures were completed. Conclusion: The research indicates that TENS was desirable to be considered as a non-invasive method for controlling pain.

Effect of Alloying Elements (Cu, Al, Si) on the Electrochemical Corrosion Behaviors of TWIP Steel in a 3.5 % NaCl Solution (3.5% NaCl 수용액 내 TWIP강의 부식거동에 미치는 합금원소 (Cu, Al, Si)의 영향)

  • Kim, Si-On;Hwang, Joong-Ki;Kim, Sung Jin
    • Corrosion Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.300-311
    • /
    • 2019
  • The corrosion behaviors of twinning-induced plasticity (TWIP) steels with different alloying elements (Cu, Al, Si) in a neutral aqueous environment were investigated in terms of the characteristics of the corrosion products formed on the steel surface. The corrosion behavior was evaluated by measuring potentiodynamic polarization test and electrochemical impedance spectroscopy. For compositional analysis of the corrosion products formed on the steel surface, an electron probe x-ray micro analyzer was also utilized. This study showed that the addition of Cu to the steel contributed to the increase in corrosion resistance to a certain extent by the presence of metallic Cu in discontinuous form at the oxide/steel interface. Compared to the case of steel with Cu, the Al-bearing specimen exhibited much higher polarization resistance and lower corrosion current by the formation of a thin Al-enriched oxide layer. On the other hand, Si addition (3.0 wt%) to the steel led to an increase in grain size, which was twice as large as that of the other specimens, resulting in a deterioration of the corrosion resistance. This was closely associated with the localized corrosion attacks along the grain boundaries by the formation of a galvanic couple with a large cathode-small anode.

Identification of Potocki-Lupski syndrome in patients with developmental delay and growth failure

  • Jun, Sujin;Lee, Yena;Oh, Arum;Kim, Gu-Hwan;Seo, Eulju;Lee, Beom Hee;Choi, Jin-Ho;Yoo, Han-Wook
    • Journal of Genetic Medicine
    • /
    • v.16 no.2
    • /
    • pp.49-54
    • /
    • 2019
  • Purpose: Potocki-Lupski syndrome (PTLS), is a recently identified, rare genomic disorder. The patients are affected by infantile hypotonia, poor growth and developmental delay. Facial dysmorphism may not be obvious in some patients. PTLS is associated with microduplication at chromosome 17p11.2. In the current study, three Korean patients are reported with their clinical and genetic features. Materials and Methods: The clinical findings of each patient were reviewed. Karyotyping and multiplex ligation-dependent probe amplification (MLPA) analyses were done for genetic diagnoses. Results: All the patients did not have the characteristic dysmorphic features, such as broad forehead, triangular face, asymmetric smile and palpebral fissures. On the other hand, all three patients were affected by variable degree of developmental delay, poor oral intake, failure to thrive, and language development disorders. Chromosome 17p11.2 duplication was identified by conventional karyotyping analysis only in one patient, whereas the other confirmed by MLPA analyses. Conclusion: Delayed development was mostly commonly observed in our patients without distinct dysmorphic facial features. In this respect, genomic screening in patients with developmental delay would identify more cases with PTLS to understand their long-term clinical courses with the development of adequate psychological and rehabilitation education program.

Exploring the Formation of Galaxies through Metallicities of Globular Clusters

  • Kim, Sooyoung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.36-36
    • /
    • 2013
  • Globular clusters (GCs) are among the oldest stellar objects in the universe and provide valuable constraints on many aspects of galaxy evolution. GC systems typically exhibit bimodal color distributions the phenomenon of which has been a major topic in the area of GC research. GC color bimodality established a paradigm where scenarios to explain its origin require two GC groups with different formation origins. The GC division, asserted mainly by photometric color bimodality so far, has been viewed as the presence of two distinct metallicity subgroups within individual galaxies. In this study, we make use of spectroscopy of GC systems associated with two giant galaxies, M31 (the Andromeda) and M87 (NGC 4486), to investigate the GC bimodality and the underlying metallicity distributions. Recent spectroscopy on the globular cluster (GC) system of M31 with unprecedented precision witnessed a clear bimodality in absorption-line index distributions of old GCs. Given that spectroscopy is a more detailed probe into stellar population than photometry; the discovery of index bimodality may point to the very existence of dual GC populations. However, here we show that the observed spectroscopic dichotomy of M31 GCs emerges due to the nonlinear nature of metallicity-to-index conversion and thus one does not necessarily have to invoke two separate GC subsystems. We present spectra of 130 old globular clusters (GCs) associated with the Virgo giant elliptical galaxy M87, obtained using the Multi-Object Spectrography (MOS) mode of Faint Object Camera and Spectrograph (FOCAS) on the Subaru telescope. M87 GCs with reliable metallicity measurements exhibit significant inflection along the color-metallicity relations, through which observed color bimodality is reproduced from a broad, unimodal metallicity distribution. Our findings lend further support to this new interpretation of the GC color bimodality, which could change much of the current thought on the formation of GC systems and their host galaxies.

  • PDF

Prediction of Near Magnetic Field Distribution of Switching ICs (스위칭 IC의 근접 자계 분포 예측)

  • Kim, Hyun-Ho;Song, Reem;Lee, Seungbae;Kim, Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.10
    • /
    • pp.907-913
    • /
    • 2015
  • This work presents a method to predict the near magnetic field distribution on the digital switching circuit mounted on PCB using co-simulation of circuit and electromagnetic fields. The proposed method first obtains the normalized near field distribution by exciting the signal and power ports of the switching circuit using sinusoidal sources. Then the real near magnetic field distribution is determined by weighting the normalized field distribution using the current spectrum of the switching circuit. To confirm the proposed method, a switching IC with a ring oscillator and a output buffer is fabricated and measured in the form of chip-on-board. The surface magnetic field distribution is measured using a magnetic probe above the PCB and compared with the simulation results. Experimental results show the correspondence between simulation and measurement results within 10 dB up to fifth harmonics.

Revaluation of Reflux Finding Score(RFS) in Laryngopharyngeal Reflux(LPR) (인후두역류증의 진단에 있어서 후두내시경검사 소견 점수화의 유용성에 대한 재검증)

  • Kwon, Kee-Hwan;Ban, Jae-Ho;Lee, Kyung-Chul
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.15 no.2
    • /
    • pp.81-86
    • /
    • 2004
  • Background and Objectives : In general, ambulatory 24-hour pH monitoring is considered the current gold standard for larynogopharyngeal reflux(LPR). There is no validated instrument whose purpose is to document the physical finding and severity of laryngopharyngeal reflux. The purposes of this study are to revaluate the validity and reliability of the reflux finding score(RFS) and to quantify laryngoscopic findings using reflux finding score. Material and Methods : Thirty-three LPR patients confirmed by dual-probe pH monitoring and thirty patients of control were selected. The RFS was documented for each patient with telescopic laryngoscopy before treatment. For test-retest intraobserver reliability assessment, a blinded laryngologists determined the RFS on two separate occasions. To evaluate interobserver reliability assessment, the RFS was determined by t재 different blinded laryngologists. Results : The mean age of the cohort with pH-documented LPR was 45.8 years and the mean RFS was 11.4. The mean age of cotrol subjects was 52 years and the mean RFS was 5.4. The mean RFS for laryngologist no. 1 was 10.8 at the initial screening and 10.9 at the repeat evaluation. The mean FRS for laryngologist no.2 was 11.1 at the intial test and 10.9 at the repeat evaluation. The correlation coefficient for interobserver variability was 0.93 and intraobserver variability was 0.94. Conclusion : The RFS demonstrates excellent inter-and introaobserver reproducibility and is helpful for quantifying laryngeal finding in LPR. We can be 95% certain that an individual with a RFS greater than 7 has LPR.

  • PDF