• Title/Summary/Keyword: Probe current

Search Result 568, Processing Time 0.026 seconds

Characteristic Analysis and Design of PC Probe for Eddy Current Testing (와전류탐상을 위한 PC 프로브의 특성해석 및 설계)

  • Kim Yong Taek;Lee Hyang-beom
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.965-967
    • /
    • 2004
  • In this paper, characteristic analysis of PC(Pancake Coil) probe with the size variation is presented for eddy current testing. Characteristics of probe are numerically calculated by using the finite element method. From the numerical analysis, the optimum frequency and groups for an experiment are selected. Probes are made and experiment is performed. From the experimental results, the probe shows maximum sensitivity when the size of defect is equal to the size of probe and when the inside diameter is similar to the width of probe and when the height is low. The result can be helpful to the standard of design of PC probe for eddy current testing.

  • PDF

BCI Probe Emulator Using a Microstrip Coupler (마이크로스트립 커플러 구조를 이용한 BCI 프로브 Emulator)

  • Jung, Wonjoo;Kim, SoYoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1164-1171
    • /
    • 2014
  • Bulk Current Injection(BCI) test is a method of injecting current into Integrated Circuit(IC) using a current injection probe to qualify the standards of Electromagnetic Compatibility(EMC). This paper, we propose a microstrip coupler structure that can replace the BCI current injection probe that is used to inject a RF noise in standard IEC 62132-part 3 documented by International Electrotechnical Commission. Conventional high cost BCI probe has mostly been used in testing automotive ICs that use high supply voltage. We propose a compact microstrip coupler which is suitable for immunity testing of low power ICs. We tested its validity to replace the BCI injection probe from 100 MHz to 1,000 MHz. We compared the power[dBm] that is needed to generate the same level of noise between current injection probe and microstrip coupler by sweeping the frequency. Results show that microstrip coupler can inject the same level of noise into ICs for immunity test with less power.

Development of Magnetic Phase Detection Sensor for the Steam Generator Tube in Nuclear Power Plants

  • Son, De-Rac;Joung, Won-Ik;Park, Duck-Gun;Ryu, Kwon-Sang
    • Journal of Magnetics
    • /
    • v.14 no.2
    • /
    • pp.97-100
    • /
    • 2009
  • A new eddy current testing probe was developed to separate the eddy current signal distortion caused by permeability variation clusters and ordinary defects created in steam generator tubes. Signal processing circuits were inserted into the probe to increase the signal-to-noise ratio and allow digital signal transmission. The new probe could measure and separate the magnetic phases created in the steam generator tubes in the operating environment of a nuclear power plant. Furthermore, the new eddy current testing probe can measure the defects in steam generator tubes as rapidly as a bobbin probe with enhanced testing speed and reliability of defect detection.

The comparison of critical currents measured by hall probe and transport methods for HTS coated conductor

  • Lee, Nam-Jin;Oh, Sang-Soo;Kim, Ho-Sup;Ha, Dong-Woo;Ha, Hong-Soo;Ko, Rock-Kil;Kim, Tae-Hyung;Kim, Hae-Jong;Song, Kyu-Jeong;Moon, Seung-Hyun;Youm, Do-Jun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.2
    • /
    • pp.11-14
    • /
    • 2009
  • We estimated the critical current distribution of the long length CCs using hall probe method, and checked the reliability by comparing with the four-probe dc transport method. The deviation ratio of $I_{c-T}$ (a measured critical current by four probe dc transport method) and $I_{c-H}$ (calculated critical current by formula (3).) was nearly smaller than 12%. The Hall probe method appeared powerful to evaluate the critical current of CCs in a reel to reel system.

Characteristics for Ground Impedance of Counterpoise according to Position of Auxiliary Probe and Frequency (보조전극의 배치 및 주파수에 따른 매설지선의 접지임피던스 특성)

  • Gil, Hyoung-Jun;Kim, Dong-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.4
    • /
    • pp.33-37
    • /
    • 2012
  • This paper describes the characteristics for ground impedance of counterpoise according to position of auxiliary probe and frequency using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position of auxiliary probes. In order to analyze the effects of ground impedance due to the distance of the current probe and frequency, ground impedances were measured in case that the distance of current probe was located from 10[m] to 100[m] and the measuring frequency was ranged in 55 [Hz], 128[Hz], 342[Hz], and 513[Hz]. The results could be help to determine the position of auxiliary probe when the ground impedance was measured at grounding system.

Electrical Properties of a Single ZnO Nanowire in a four-probe Configuration (단일 ZnO 나노선 4단자 소자의 전기적 특성)

  • Kim, Kang-hyun;Kang, Hae-yong;Yim, Chan-young;Jeon, Dae-young;Kim, Hye-young;Kim, Gyu-Tae;Lee, Jong-Soo;Kang, Woun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.12
    • /
    • pp.1087-1091
    • /
    • 2005
  • Four-probe device of single ZnO nanowire was fabricated by electron beam lithography. Electrical characterizations in a two-probe and a four-probe configuration with a back-gate were carried out to clarify the relative contribution of the contact and the intrinsic part in a ZnO nanowire. I-V characteristic in four-probe measurement showed an ohmic behavior with a high conductivity, 100 S/cm, which was better than those of two-probe measurement by 10 times. At the same values of the current between two-probe and four-probe, the net voltage applied inside the nanowire were extracted with calculated voltages at the contact. Four-probe current-gate voltage characteristics showed bigger tendencies than those of two-probe measurement at low temperatures, indicating the reduced gate dependence in two-Probe measurements by the existence of the contact resistance.

Inspection of Welded Zone and Flat Plate Using Flexible ECA Probe (Flexible ECA Probe를 이용한 평판 및 용접부 검사)

  • Lee, Chang-Jun;Lee, Kyu Sung;Shin, Chung-Ho;Lee, Kyoung-Jun;Jang, Yoon Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.4
    • /
    • pp.288-294
    • /
    • 2016
  • This paper aims to compare the ability to detect notch defects existing in the plate and welded area using a flexible ECA (eddy current array) probe with OmniScan MX and MS-5800E. The characteristics of signals with various frequencies and lift-offs were also compared. As a result, when signals of frequencies 500, 1000, and 1500 kHz were used, the amplitude of the signal increased, as the depth of the notch increased, but reduced linearly in accordance with the lift-off variation. In addition, the detection sensitivity of the weld defect was found to be closely related to the contact surface of the probe and specimen. In this paper, it was demonstrated that the detection sensitivity was excellent when the contact surface of the probe and the specimen was sufficient, but it was poor when the contact surface was insufficient.

Review paper: Application of the Pulsed Eddy Current Technique to Inspect Pipelines of Nuclear Plants

  • Park, D.G.;Angani, C.S.;Kishore, M.B.;Vertesy, G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.342-347
    • /
    • 2013
  • Local wall thinning in pipelines affects the structural integrity of industries, such as nuclear power plants (NPPs). In the present study, a development of pulsed eddy current (PEC) technology that detects the wall thinning of pipelines covered with insulation is reviewed. The methods and experimental results, which have two kinds of probe with a single and double core, were compared. For this purpose, the single and double core probes having one and two excitation coils have been devised, and the differential probe with two Hall sensors has been fabricated to measure the wall thinning in insulated pipelines. The test sample is a stainless steel having different thickness, laminated by plastic insulation to simulate the pipelines in NPPs. The excitation coils in the probe is driven by a rectangular current pulse, the difference of two Hall sensors has been measured as a resultant PEC signal. The peak value of the detected signal is used to describe the wall thinning. The double core probe has better performance to detect the wall thinning covered with insulation; the single core probe can detect the wall thinning up to an insulation thickness of 18 mm, whereas the double probe can detect up to 25 mm. The results show that the double core PEC probe has the potential to detect the wall thinning in an insulated pipeline of the NPPs.

Design of Current Probe Using Faraday Effect of Optical Fiber (광 파이버의 패러데이 효과를 이용한 전류측정용 프로브 설계)

  • Kang, Hang-Sik;Kim, Chul-Ju
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1278-1280
    • /
    • 1995
  • A probe type fiber-optic sensing techique for electric current measurement is applied in this paper. The technique is based on the Faraday effect which meaning is that polarization state of light is rotated by magnetic field. In experiment, test wire is located at inside and outside of the probe to be measured. The experimental results prove not only linear property, but also polarization rotation property according to the distance from outside of probe.

  • PDF

Comparison of ECT Probes in Diagnosis of Defects

  • Mun, Ho-Young;Kim, Chang-Eob
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.190-196
    • /
    • 2014
  • In this paper, the characteristics of a defective elliptical aluminum plate are analyzed by three different eddy current testing probes; T/R, T/T, and Impedance probes. The analysis was done by 3D finite element method, and the impedance change of real and imaginary voltage values were analyzed.