• Title/Summary/Keyword: Primary energy consumption

Search Result 182, Processing Time 0.027 seconds

Energy Consumption status of Apartment Buildings and Influence of Various Factors on Energy Consumption (공동주택의 에너지사용량 실태 분석 및 각종 인자가 에너지사용량에 미치는 영향 분석)

  • Kim, Yong-In;Song, Seung-Yeong
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.93-102
    • /
    • 2014
  • The aim of this study is to analyze the influence of various factors on energy consumption of apartment buildings. Energy consumption data of the Green Together, integrated building energy management system maintained by the government were used, and end-use and primary energy consumption data of 2012 were analyzed for 181 apartment complexes completed between 2004 and 2011 in Seoul. Energy consumption by use, source and heating type were analyzed. Then, energy consumption trends were analyzed and suggested according to energy efficiency ratings, number of households, areas for exclusive use, number of floors, core types, building types, orientations and completion years.

Energy Performance Evaluation of A Primary School Building for Zero Energy School (제로에너지 스쿨을 위한 초등 교육시설의 에너지 성능평가)

  • Yoon, Jong-Ho;Shin, U-Cheul;Cho, Jin-Il;Park, Jae-Wan;Kim, Hyo-Jung;Lee, Chul-Sung
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.121-126
    • /
    • 2009
  • This study analyzed the standard school's energy usage and patterns as the zero-energy goal of primary school building, and proposed the energy reduction process of school building using energy analysis computing simulation tool. As a analysis simulation tool, Visual DOE 4.0 is used. For analysis of actual energy usage, selected primary school that is standard in the nation's energy consumption. Standard of the school's energy consumption analysis were devided into electric and gas energy. Input parameters of the simulation program based on the literature material and field survey material. after, but it was calibrated to comparison with the standard school's energy consumption. Finally, its energy usage analyzed by component and made the priority order of energy saving. Applied energy saving technologies are envelopment insulation, high efficiency lighting, high performance HAVC system and used active equipment system of solar collector and photovoltaic generation for additional savings.

  • PDF

The Influence of Unit Plan Shapes to the Energy Efficiency of Collective Housing Simulated by ECO2 Software (ECO2 프로그램을 이용한 공동주택의 단위세대 평면 형태에 따른 에너지 효율 평가)

  • Kim, Chang-Sung
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.89-94
    • /
    • 2015
  • Purpose: Various policies to reduce the energy consumption have been carried out to save Earth environment against global warming and environmental pollution in many countries. Energy consumption of buildings in Korea has reached 24% of total energy consumption, and energy consumption of apartment has been continuously increasing. Therefore, Korea government has executed building energy efficiency rating certification system to control energy consumption of buildings. Method: This study was conducted to evaluate the energy performance of apartment unit plans according to the increasement of front width of unit plans, and tried to present the basic data to design more energy conscious unit plans for apartments. For the study, three shapes of unit plans -the 2Bay, 3Bay and 4bay unit- were selected for imput models. They were simulated using ECO2 software to assess building energy efficiency rating certification in Korea. Result: According to the results, in cases that balcony windows were not installed, the primary energy consumption of the 3Bay and 4Bay units were less than 2Bay unit, respectively, 0.1% and 2,5%. The primary energy consumption of the 3Bay and 4Bay units, in cases that balcony windows were installed, was less than 2Bay unit, respectively, 1.7% and 3.2%.

Energy Consumption Evaluation in Pumping System with Different Building Characteristics (건물 특성에 따른 냉수 순환 펌핑 시스템 별 에너지 소모량 분석)

  • Shin, Dong-Shin;Park, Sung-Bin;Jun, Tae-Ik;Ma, Kang-Il;Kim, Tae-Hong;Lee, Sung-Goo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.242-247
    • /
    • 2016
  • This study analyzed the energy consumption of a building pump system that was originally equipped with a primary-secondary zone pump system. Using the HYSYS program the energy consumption of the primary pump system was compared with the primary-secondary zone pump system. The primary-secondary zone pump system consumes less energy than the originally designed primary pump system. When the distance between the machine room and each building is assumed to be equal, the primary pump system can be more efficient than the primary-secondary zone pump system with decreasing the distance. When the distance is 120 m, the primary system consumes less total annual energy than the primary-secondary zone pump system and saves 2,773 kWh. The suggested energy evaluation program can be useful if the designer seeks a more efficient pump system.

A Study on the Building Energy Efficiency Rating Changes by Enhanced Thermal Insulation Performance of Building Envelope Standards in Apartment Houses (공동주택에서 외피단열성능기준 강화에 따른 건축물에너지 효율등급 변화에 관한 연구)

  • Cho, Yeong Uk;Park, Sun Hyo;Joung, Kwang Sub
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • This study aimed to compare the primary heating energy consumption of regional apartment houses based on the enhanced thermal insulation performance of building envelope standards. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the southern region, the largest regional difference in primary heating energy consumption, is $10.3kWh/(m^2{\cdot}year)$. The difference of the heating energy consumption based on the enhanced thermal insulation performance of building envelope standards in the central region is $8.0{\sim}8.5kWh/(m^2{\cdot}year)$ and that of the Jeju region is $0.5kWh/(m^2{\cdot}year)$. These energy consumption differences do not result in building energy efficiency ratings changing. The building energy efficiency ratings have the possibility to be changed.

A Case Study for Energy Consumption Characteristics of High School Facilities in Seoul (서울지역 고등학교 건물의 에너지소비특성에 관한 사례분석)

  • Kim, Sung-Bum;Oh, Byung-Chil;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.61-69
    • /
    • 2016
  • In this study, we analyzed five-year(2011~2015) data for D high school in Seoul area to analyze energy consumption characteristics in high school. The results are summarized as follows. (1) In the result of comparison analysis about 2015 energy consumption by usage, based on primary energy, 18% of energy was consumed in cafeteria, and 82% was consumed in main building. In the case of main building, base and constant load excepting hot water supply in restroom took 40%, heating including freeze protection took 20%, hot water supply in restroom took 14%, and cooling took 8% in order. (2) In the 2015 total energy consumption in D high school based on primary energy, heating energy takes 28%. The range and limit of energy savings coming from the reinforcement of insulation and window performance could be estimated. (3) To introduce new & renewable energy system in high school, electricity-based system is suitable than heat-based system because usage of electric energy is larger than that of heat energy in high school. (4) Five-year energy consumption unit according to heating degree-day showed a linearly increasing trend, and the coefficient of determination(R2) was 0.9763, which means high correlation.

Comprehensive Analysis of Energy Consumption Rate and New Technology Trend in High-Performance Buildings related with Different Climatic Zones (세계 기후대별 High-Performance Buildings의 에너지 소비 원단위 평가 및 신기술 적용 동향 분석 연구)

  • Kim, Chul-Ho;Lee, Seung-Eon;Kim, Kang-Soo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.11
    • /
    • pp.63-72
    • /
    • 2018
  • In this study, we analyzed high-performance building technologies through a case study of 65 high-performance buildings in the U.S., Europe, Asia and Oceania. In detail, we reviewed the international trend of building energy-saving technology and energy consumption per unit area by analyzing buildings constructed within a 10 year period(2008-018). The primary energy consumption was $48-440kWh/m^2$, and the average value was calculated as $169.3kWh/m^2$. Although some buildings received high certification ratings, they did not meet either Korean or international energy evaluation standards. The system analysis revealed that many energy-saving technologies show various application rates in different countries because the technologies possess different properties. Furthermore, small-area building groups tended to have less primary energy consumption than the medium and large-area buildings, but the area-energy relationship $R^2$ value was analyzed as 0.3161, indicating no clear proportional relationship. Therefore, we propose that it is necessary to maximize the energy savings of buildings by taking into consideration a region's code, climate, building usage, area and space-using patterns to reduce energy and greenhouse gas emissions.

A Study on Analysis of Energy Consumption of the Middle School Facilities in Korea (전국 중학교 시설의 에너지 사용실태 분석 연구)

  • Yoon, Jong-Ho;Shin, U-Cheul;Cho, Jin-Il;Park, Jae-Wan;Kim, Hyo-Jung
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.45-50
    • /
    • 2010
  • This study for middle school facilities is second following the study of the energy consumption of primary school facilities. There is not on the analysis of the current energy usage for middle school facilities in nations to set goals of energy reduction. Therefore, The purpose of this study is to present various analysis result of energy consumption which is a statistical analysis of domestic middle school facilities in South Korea. As a consequence, each average energy consumption at the domestic middle school facilities analyzed as following after changing as unit 'kWh' only for comparison with every energy source. It represents that the energy consumption of electric power was 183.7MWh(70.2%), gas consumption for heating was 46.5MWh(17.8%), oil consumption was 26.5MWh(10.1%), district energy was 5.1MWh(1.9%). This result describes that consumption of electric power was large greatly and it reflects the expectation that it will climb the demand regarding this energy in the future. In additionally, it analyzed average energy consumption with $74.4kWh/m^2$ by the unit area of air-conditioning and the district which has large energy consumption was Seoul with $91.6kWh/m^2$.

Comparative Studies on Lighting Environment and Energy Performance depending on the Transmittance of Window and Slat Angle of Blind (창호의 투과율과 블라인드 슬랫각도에 따른 빛환경 및 에너지성능 비교 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.256-263
    • /
    • 2011
  • Recently, curtain wall structure is constructed according to increasing high rise building. Glass is usually used in opening of curtain wall structure and window area ratio is finally increased. Excessive Daylighting and solar radiation by large window area ratio cause discomfort glare and add to cooling load in the case of office that is heavy on lighting and cooling. Therefore, this study suggests to use low transmittance window for solve those problems. Indoor lighting environment and building energy performance were analyzed by increasing transmittance from 10% to 90% and comparing fixed venetian blind. Consequently, the range of transmittance that is possible to daylighting and prevent discomfort glare. Secondary energy consumption is efficient in the case that transmittance is the range of from 20% to 50%, primary energy consumption is nice on from 20% to 40%. If those result put together, the range of window transmittance from 30% to 50% is proper in the office in lighting environment and energy consumption aspects.

  • PDF

A Comparison of Decomposition Analyses for Primary and Final Energy Consumption of Korea (우리나라 1차 에너지와 최종 에너지 소비 변화요인 분해 비교분석)

  • Park, Sungjun;Kim, Jinsoo
    • Environmental and Resource Economics Review
    • /
    • v.23 no.2
    • /
    • pp.305-330
    • /
    • 2014
  • There has been a lot of studies to identify the driving forces of energy consumption. Many of them decomposed the final energy consumption into the intensity effect, structural effect, and production effect. Those approach, however, could not consider the transformation loss during the electric power generation. Therefore, in this study, we conducted a decomposition analysis on the primary energy use basis to reflect that transformation loss. Log mean Divisia index and refined Laspeyres methods were used for the index decomposition. As results, we could find out that the difference between two approaches were definite. The intensity effect in 2011 is -0.607 times against 1981 in the final energy case, but -0.236 times in the primary energy case. The structure effect in 2011 is 0.227 times against 1981 in the final energy case, but 0.434 times in the primary energy case. Therefore, an analysis on the primary energy basis is essential when conducting a decomposition analysis.