Energy Consumption Evaluation in Pumping System with Different Building Characteristics  

Shin, Dong-Shin (Department of Mechanical System Design Engineering, Hongik University)
Park, Sung-Bin (Department of Mechanical System Design Engineering, Hongik University)
Jun, Tae-Ik (Department of Mechanical System Design Engineering, Hongik University)
Ma, Kang-Il (Department of Mechanical System Design Engineering, Hongik University)
Kim, Tae-Hong (Department of Mechanical System Design Engineering, Hongik University)
Lee, Sung-Goo (HIMEC Co., Ltd.)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.28, no.6, 2016 , pp. 242-247 More about this Journal
Abstract
This study analyzed the energy consumption of a building pump system that was originally equipped with a primary-secondary zone pump system. Using the HYSYS program the energy consumption of the primary pump system was compared with the primary-secondary zone pump system. The primary-secondary zone pump system consumes less energy than the originally designed primary pump system. When the distance between the machine room and each building is assumed to be equal, the primary pump system can be more efficient than the primary-secondary zone pump system with decreasing the distance. When the distance is 120 m, the primary system consumes less total annual energy than the primary-secondary zone pump system and saves 2,773 kWh. The suggested energy evaluation program can be useful if the designer seeks a more efficient pump system.
Keywords
Chilled water; Primary pump system; Primary-Secondary pump system; Primary-Secondary zone pump system;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Korea energy information center, 2004, Selection of the Air-conditioning system, Energy equipment magazine, Vol. 12, pp. 1-9.
2 Kim, K. T., Lee, S. Y., Yeo, M. S., and Cho, H. G., 1999, A Comparative Study on the Operating Methods for the Secondary pump in Chilled Water Distribution System, Proceeding of SAREK, pp. 864-868.
3 Lee, S. O., 2014, The optimal pump system and minimizing energy consumption, SAREK Journal, Vol. 43, No. 4, pp. 36-41.
4 Taylor, S. T., 2002, Primary-Only vs. Primary-Secondary Variable Flow System, ASHRAE Journal, pp. 25-29.
5 Yeon, C. K., Lee, S. K. and Kim, M. H., 2009, The primary-secondary pump system design case using geothermal heat pump, KARSE, Vol. 26, No. 6, pp. 75-80.
6 Hyprotech, 2003, HYSYS 3.2 Operation Guide.
7 Lee, H., 2010, Pumping system of chilled water pipeline, Proceeding of SAREK, pp. 402-407.
8 Luther, K. R., 1998, Variable volume pumping fundamentals, HPAC, pp. 69-75.
9 HYOSUNG EBARA CO. LTD., 2007, HYOSUNG Pump Catalog.