• Title/Summary/Keyword: Previous Risk Evaluation

Search Result 144, Processing Time 0.029 seconds

A Study on the Risk Evaluation of Construction Management Based on Risk Identification (위험도 기반 건설경영 리스크 평가에 관한 연구)

  • Lee, Hyun-Chul;Lee, Gun;Yeo, Sang-Ku;Go, Seong-Seok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.3
    • /
    • pp.83-91
    • /
    • 2009
  • Construction industry is a complex industry which should be invested with plenty capital, manpower and resources. Investment factors and inner and outer environmental factors should be managed systemically in terms with risk factors possible to occur. It maximizes the profit to establish construction management by managing risk systemically. While previous studies were executed with risk related to some special progress lively, studies about risk in managing construction company leave much to be desired. Therefore, this study examined risk in the whole construction management, showed the checklist and deduced the quantitative factors through questionnaire analysis from specialists. Also, priority and grade of construction management factors were evaluated by analyzing weight of construction risk factors.

The Impact of IT Project Size and Types on IT Investment Decision Criteria (IT프로젝트 규모와 유형에 따른 IT투자 의사결정기준의 차이)

  • Lee Kukhie
    • Journal of Information Technology Applications and Management
    • /
    • v.12 no.1
    • /
    • pp.191-211
    • /
    • 2005
  • This study investigates the decision criteria used in the context of IT investment decision making and empirically analyzes the impact of IT project size and types on the importance of decision criteria. 5 criteria which have been extracted from the previous studies and industry practices are budget, financial benefits. strategic value. risk, and the degree of proposer's eagerness. Data of 120 IT project proposals have been collected from 5 companies including bank, insurance. and stock trading company. As results of ANOVA test. 7 out of 10 hypothesis have been accepted statistically. That is. the bigger the project size. the higher the evaluation weight of project budget and risk criteria and the lower the weight of proposer's eagerness. And in case of the infrastructure investment type. the emphasis is placed more on strategic value and risk criteria and less on financial benefit and proposer's eagerness. These findings provide insights for both IT practitioners and researchers.

  • PDF

Comparison of Shipyard Worker Self-reported and Expert-observed Method using the Same Checklist for Ergonomic Risk Factors (근골격계질환 위험요인에 대한 조선업 근로자 자가평가와 전문가 관찰 방법 비교)

  • Lee, Yun-Keun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.2
    • /
    • pp.83-89
    • /
    • 2005
  • This study aims to compare a self-reported and expert-observed method on ergonomic risk factors of Work-related Musculoskeletal Disorders (WMSDs). The checklist was developed based on the results of previous studies, and the symptoms of WMSDs were obtained using a self-reported questionnaire from 1,029 shipyard workers. The risk factors were assessed through the self-report by workers and video analysis by ergonomists. The symptom prevalence at the low back (59.2%), shoulders (50.8 %), and knees (49.7%) were relatively higher than those at other body parts. Odds ratios (ORs) by body parts were 2.48 to 2.90 for the risk job, and the ORs were significantly different from those of the low risk job. The risk factor scores by body parts between workers and ergonomist were very high correlation(r=0.82 to 0.92). The rates of self-report from risk job were 54.0% (elbow and arm) to 72.1 % (low back), but sometimes overestimated(105.7 to 122.6%) than those by ergonomists. The checklist, developed in this study, will be an efficient tool for the evaluation of risk jobs using self-report by workers.

Generation of local wind pressure coefficients for the design of low building roofs

  • Kumar, K. Suresh;Stathopoulos, Ted
    • Wind and Structures
    • /
    • v.4 no.6
    • /
    • pp.455-468
    • /
    • 2001
  • This paper presents recent research on the experimental evaluation of wind loads on low buildings and the recommendations provided in the form of traditional codification. These mainly include the wind loads on buildings with geometries different from those examined in previous studies. This is followed by the evaluation of simulated wind loads on low building roofs. The overall application of a recently proposed simulation methodology for codification purposes is discussed in detail. The traditional codification provides for a group of roof geometries a single peak design pressure coefficient for each roof zone considering a nominal worst-case scenario; this may often lead to uneconomical loads. Alternatively, the presented methodology is capable of providing peak pressure coefficients corresponding to specific roof geometries and according to risk levels; this can generate risk consistent and more economical design wind loads for specific roof configurations taking into account, for instance, directional design conditions and upstream roughnesses.

Fall Risk Assessment (FRA) of Korean community-dwelling elderly (지역 재가 노인의 낙상위험평가)

  • Shin, Sohee;Sato, Susumu
    • 한국노년학
    • /
    • v.39 no.4
    • /
    • pp.895-902
    • /
    • 2019
  • This study reviewed the diagnosis accuracy and evaluation criteria of the fall risk assessment questionnaire that proved validity through factor analysis in previous studies. The purpose of this study was to diagnose high-risk groups and propose personal fall risk profiles for the Korean community-dwelling elderly. The participants of this study were 439 elderly people living in S, U, B, and Y cities Korea (mean age 75.0 ± 5.7 years). Receiver operating characteristic analysis was conducted to review the accuracy of the fall risk assessment and evaluation criteria of the FRA. The results showed that the four sub-factors of the FRA: 'Potential for fall', 'Disease and physical symptoms', 'Environment' and 'Physical function', can effectively diagnose the fall risk of the community-dwelling elderly. The evaluation criteria was presented based on the sensitivity and specificity results. In addition, as a result of analyzing the patterns by the sub factors of the fall risk, the high-risk group accounted for 80% of the elderly who had problems with two or more factors. Therefore, the four sub-factors of FRA can effectively diagnose the fall risk level, and could be present individual fall risk profiles based on the evaluation criteria.

Health risk assessment by CRPS and the numerical model for toluene in residential buildings

  • Choi, Haneul;Kim, Hyungkeun;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.17 no.5
    • /
    • pp.33-41
    • /
    • 2017
  • Purpose: Indoor air quality in residential buildings needs to be evaluated over the long term. In previous research, there has been an attempt to perform the health risk assessment of pollutants by using numerical models as a method of long-term evaluation. However, the numerical model of this precedent study has limitations that do not reflect the actual concentration distribution. Therefore, this study introduces the CRPS index, constructs a numerical model that can reflect the concentration distribution, and then presents a more accurate health risk assessment method using it. At this time, the pollutants are toluene, which is a typical material released from building materials. Method: CRPS index was applied to existing numerical model to reflect concentration distribution. This was used to calculate concentrations at adult breathing area and to use them for exposure assessment in a health risk assessment. After that, we entered adult data and conducted a health risk assessment of toluene. Results: The non-carcinogenic risk of toluene was calculated to be 0.0060. This is 5% smaller than the existing numerical model, meaning that it is more accurate to predict the pollutant risks. This value is also lower than the US EPA reference value of 1. Therefore, under the conditions of this study, long-term exposure of adults to toluene has no impact on health.

A Review of the Quantitative Evaluation Indexes of Barrier-Free Certification for Floor and Ground Surfaces Safety (BF 인증기준의 바닥 안전성에 관한 정량적 평가지표 검토)

  • Ji, Suk-Won;Baik, Kwon-Hyuk;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.27-28
    • /
    • 2021
  • For Barrier-Free certification, the floor and ground surfaces must be finished with materials that are not slippery, flat, and have low-impact in fallis. However, the BF Certification Act does not provide specific methods to meet these regulations. In performance-based design, the responsibility of proving the performance rests with the building owner and architect, so quantitative evaluation indexes are needed to select suitable materials. Furthermore, changes in performance after completion should be checked periodically in 'As-Is' conditions. There are various methods for slips, trips and falls risk assessment, causing confusion for users. In this study, the results of previous studies on the evaluation methods of slips, trips and falls were considered closely, and each quantitative evaluation index that can be used in the new construction and maintenance phase was presented.

  • PDF

Evaluation of Balance Capability in Facilities Maintenance Workers using Screening Tools (스크리닝 도구를 이용한 건물관리업 종사자의 균형감각능력 평가)

  • Choi, Hyung Jin;Kim, Jung Soo
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.81-88
    • /
    • 2014
  • A number of screening tools have been developed to evaluate the human balance capability. Many of them were designed to identify the elderly with falling risk. Three different screening tools, which have been well used many clinical fields, were used in this study. The purpose of this study was to evaluate balance capability in facilities maintenance workers in korea. There were no statistical significance between male and female when evaluated with three different screening tools. However, significant differences were found among the age groups irrespective of gender when evaluated with three different screening tools. The results of three different screening tools in korea showed poor values compared with previous results. These results revealed that facilities maintenance workers faced more critical falling risk in korea.

A novel risk assessment approach for data center structures

  • Cicek, Kubilay;Sari, Ali
    • Earthquakes and Structures
    • /
    • v.19 no.6
    • /
    • pp.471-484
    • /
    • 2020
  • Previous earthquakes show that, structural safety evaluations should include the evaluation of nonstructural components. Failure of nonstructural components can affect the operational capacity of critical facilities, such as hospitals and fire stations, which can cause an increase in number of deaths. Additionally, failure of nonstructural components may result in economic, architectural, and historical losses of community. Accelerations and random vibrations must be under the predefined limitations in structures with high technological equipment, data centers in this case. Failure of server equipment and anchored server racks are investigated in this study. A probabilistic study is completed for a low-rise rigid sample structure. The structure is investigated in two versions, (i) conventional fixed-based structure and (ii) with a base isolation system. Seismic hazard assessment is completed for the selected site. Monte Carlo simulations are generated with selected parameters. Uncertainties in both structural parameters and mechanical properties of isolation system are included in simulations. Anchorage failure and vibration failures are investigated. Different methods to generate fragility curves are used. The site-specific annual hazard curve is used to generate risk curves for two different structures. A risk matrix is proposed for the design of data centers. Results show that base isolation systems reduce the failure probability significantly in higher floors. It was also understood that, base isolation systems are highly sensitive to earthquake characteristics rather than variability in structural and mechanical properties, in terms of accelerations. Another outcome is that code-provided anchorage failure limitations are more vulnerable than the random vibration failure limitations of server equipment.

A Harmonized Method for Dose-response Risk Assessment Based on the Hazard & Risk Evaluation of Chemicals (HREC) According to the Industrial Safety and Health Act (ISHA) (산업안전보건법 상 유해성.위험성 평가제도 적용을 위한 양-반응 평가의 통일화 방안 연구)

  • Lim, Cheol-Hong;Yang, Jeong-Sun;Park, Sang-Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.3
    • /
    • pp.175-183
    • /
    • 2012
  • Objectives: This study developed a harmonized method for risk assessment based on the Hazard & Risk Evaluation of Chemicals (HREC) according to the Industrial Safety and Health Act (ISHA). Methods: Three preliminary studies, performed during 2010 and 2011 by the Occupational Safety and Health Research Institute and three academic research groups, were compared. The differences in risk assessment, especially in the dose-response assessment method, were analyzed. A new harmonized method for dose-response assessment was suggested and its applicability for the HREC was examined. Results: Considering the various steps of each dose-response assessment, the equivalent steps in quantitative correction, uncertainty factor 2 (UF2) for intra-species uncertainty, and UF3 for the experimental period in the uncertainty correction were relatively high. Using our new method, the total correction values (quantitative correction plus uncertainty correction) ranged from 72~15,789 to 30~60, and the ratio of the threshold limit value (TLV) to the reference concentration decreased from 12.8~1900 to 5.4~11.8. Furthermore, when we performed risk characterization by our new method, hazard quotient (HQ) values for chloroethylene, epichlorohydrin, and barium sulfate became 3.0, 14.1, and 1.13 respectively, whereas three previous studies reported HQ values of 7.1, 4580, and 87.3 considering reasonable maximum exposure (RME) conditions. HQs of the three chemicals were calculated to be 0.6, 2.4, and 0.1 respectively, when compared to their TLVs. Conclusions: Our new method could be applicable for the HREC because the total correction values and the ratio of TLVs were within reasonable ranges. It is also recommended that additional risk management measures be applied for epichlorohydrin, for which the HQ values were greater than 1 when compared with both reference values and the TLV. Our proposed method could be used to harmonize dose-response assessment methods for the implementation of risk assessment based on the HREC according to ISHA.