• Title/Summary/Keyword: Pressure-Drop

Search Result 2,352, Processing Time 0.031 seconds

An Experimental Study on Condensation Heat Transfer Characteristics and Pressure Drop of Plate Heat Exchangers using the Alternative Refrigerant R410A (대체 냉매 R410A를 적용한 판형열교환기의 응축열전달 특성 및 압력강하에 대한 실험적 연구)

  • Kim, Y.H.;Han, D.H.;Lee, K.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.220-225
    • /
    • 2001
  • The plate heat exchanger is characterized. by low pressure drop and high heat transfer coefficient. The experimental study has been performed on the condensation heat transfer and pressure drop characteristics of the plate heat exchangers in this study. In the present study, a brazed type plate heat exchanger was investigated at a chevron angle of $45^{\circ},\;55^{\circ},\;and\;70^{\circ}$ with R410A. Condensation temperatures were varied from $20^{\circ}C\;and\;30^{\circ}C$, and mass flux was ranged from $13{\sim}34\;kg/m^{2}s$ with constant heat flux ($=5\;kw/m^{2}$). The heat transfer coefficient and pressure drop increased with the chevron angle. Average condensation heat transfer coefficients and pressure drops are decreased with increasing condensation tempeature.

  • PDF

Design and Performance Test of Plate Type ER-Valve (평판형 ER-Valve의 제작 및 성능실험)

  • 장성철;염만오
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.6
    • /
    • pp.29-35
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-valves are measured with varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. If we allow the same electric field in the ER-Valve, we came to how that the pressure drop is effected by the electrode length and electrode width. When the strength of the electric field increased, the pressure drop happened big and the flow rate decreased.

Experiment on condensation heat transfer and pressure drop characteristics in the multi-channel flat tube (다채널 편평관의 응축 열전달 및 압력강하특성에 관한 실험)

  • Jeon, C.D.;Chung, J.W.;Lee, J.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.376-388
    • /
    • 1997
  • In this study, an experiment was performed to investigate the characteristics of pressure drop and heat transfer of multi-channel tubes for automotive condenser using HFC-134a as an alternative refrigerant. The mass flux and inlet saturation pressure of the refrigerant were controlled, respectively, in the range of 200 to $500kg/m^2s$ and 1.0 to 1.6MPa. Pressure drop and heat transfer coefficient were compared with the previously proposed correlations and new correlations based on Traviss' correlation were suggested. Prediction of pressure drop and heat transfer coefficient based on the new correlations agrees with experimental results within ${\pm}9%$ and -18~+11%, respectively.

  • PDF

Characteristics of Pressure Drop in SMX Type Motionless Mixers (SMX형 정적 믹서의 압력손실 특성)

  • Yang, Hei-Cheon;Park, Jeong-Il
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.6
    • /
    • pp.479-486
    • /
    • 2008
  • The objective of this study is to investigate experimentally the characteristics of pressure drop in SMX type motionless mixers. The motionless mixers used are SMX-O, SMX-H, SMXL-O and SMXL-H ones. The SMX-H and SMXL-H mixer elements have been designed to reduce the pressure drop as compared with the SMX-O and SMXL-O ones. The Reynolds number based on the bulk average properties of the water is in a range of 5000 to 13000. The pressure drops across the motionless mixers are measured and the friction factors are calculated using the pressure drop data. On the average, the friction factors of the SMX-H and SMXL-H mixers are about 8% and 15% lower than those of the SMX-O and SMXL-O ones. In addition, the proposed correlations from the experimental data for the friction factor are presented and compared with those obtained from the literature.

Influence of Turning Region and Channel Rotation on Pressure Drop in a Square Channel with Transverse Ribs (90° 요철이 설치된 정사각 덕트 내 압력강하에 곡관부 및 회전이 미치는 영향)

  • Kim, Kyung-Min;Lee, Dong-Hyun;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.2 s.245
    • /
    • pp.126-135
    • /
    • 2006
  • The pressure drop characteristics in a rotating two-pass duct with rib turbulators are investigated in the present study. The square duct has a hydraulic diameter $(D_h)$ of 26.7 mm, and $1.5mm{\times}1.5mm$ square $90^{\circ}-rib$ turbulators are attached on the leading and trailing walls. The pitch-to-rib height ratio (p/e) is 10. The distance between the tip of the divider and the outer wall of the duct is $1.0D_h$ and the width of divider wall is 6.0mm or $0.225D_h$. The Reynolds number (Re) based on the hydraulic diameter is kept constant at 10,000 to exclude the Reynolds effect, and the rotation number (Ro) is varied from 0.0 to 0.20. The pressure drop distribution, the friction factor and thermal performance are presented for the leading, trailing and the outer surfaces. It is found that the curvature of the $180^{\circ}$-turn produces Dean vortices that cause high pressure drop in the turn. The channel rotation results in pressure drop discrepancy between leading and trailing surfaces so that non-dimensional pressure drops are higher on the trailing surface in the first-pass and on the leading and side surfaces in the second-pass. In the turning region, Dean vortices shown in the stationary case transform into one large asymmetric vortex cell, and subsequent pressure drop characteristics also change. As the rotation number increases, the pressure drop discrepancy enlarges.

A Study on the Pressure drop Variance of Pulse interval, injection distance in Pulse Air Jet Type Bag Filter (충격기류식 여과집진장치의 펄스간격 밀 분사거리에 따른 압력손실변화에 관한 기초 연구)

  • Seo, Jeong Min;Choe, Geum Chan;Park, Jeong Ho
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.223-232
    • /
    • 2004
  • The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to $50mmH_2O$ varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/㎥ and 1g/㎥, the pressure $drop(\DeltaP)$ was stable 60 to 90minutes after operation. For the higher concentration of 3g/㎥, as $\DeltaP$ continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 1l0mm, when inlet dust concentration is 0.5g/㎥ or 1g/㎥, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/㎥ and 3g/㎥ has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.

An Experimental Study on Effects of Soot Loading and Mass Flow Rate on Pressure Drop and Heat Transfer in Catalyzed Diesel Particulate Filter (촉매 코팅 DPF의 soot loading과 유량 변화에 따른 압력강하 및 열전달에 관한 실험적 연구)

  • Cho, Yong-Seok;Noh, Young-Chang;Park, Young-Joon;Kim, Duk-Sang
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.72-78
    • /
    • 2007
  • A diesel particulate filter causes progressive increase in back pressure of an exhaust system due to the loading of soot particles. To maintain the pressure drop caused by DPF under proper level, a regeneration process is mandatory when excessive loading of soot is detected in the filter. It is a major reason why the relation between the amount of soot and the pressure drop in a DPF becomes crucial. On the other hand, pressure drop varies with not only the soot loading but also conditions of exhaust gas such as mass flow rate. Therefore, the relation among them becomes complicated. Furthermore, the characteristics of heat transfer in a DPF is another crucial parameter in order for the filter to avoid thermal crack during regeneration period. This study presents characteristics of pressure drop under various conditions of soot loading and mass flow rate in catalyzed diesel particulate filter. This study also shows characteristics of heat transfer in DPF when high temperature gas flows into the filter. Experiments reveal that the soot loading and mass flow rate affect characteristics pressure drop independently. Experiments also indicate that the amount of coating material has little influence on pressure drop with changes in soot loading and mass flow rate. However, increased catalyst coating may lead to the improved heat transfer which is efficiency to reduce thermal stress of the filter.

Pressure Drop Analysis on Filling of Hydrogen Fuel Cell Vehicles (수소연료전지 차량 충전에서의 압력강하 분석)

  • Hyo Min Seo;Byung Heung Park
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.38-47
    • /
    • 2023
  • In the hydrogen filling process, hydrogen flows by the pressure difference between the supply pressure at a filling station and a storage tank in the vehicle, and the flow rate depends on the pressure difference. Therefore, it is essential to consider the pressure drop of hydrogen occurring during the filling process, and the efficiency of the hydrogen filling process can be improved through its analysis. In this study, the pressure drop was analyzed for a hose, a nozzle/receptacle coupling, a pipe, and a valve in a filling line. The pressure drops through hose and pipe, the nozzle,receptacle coupling, and the valve were calculated by using a equation for a straight conduit, a flow nozzle formula, and a gas flow respectively. In addition, as a result of comprehensive analysis of the pressure drop effect occurring in each component, it was found that the factor that has the greatest influence on the pressure drop in the entire filling line is the pressure drop through the valve. This study can be used to develop a model of the hydrogen filling process by analyzing hydrogen flow including hydrogen filling in the future.

Pressure Drop Predictions Using Multiple Regression Model in Pulse Jet Type Bag Filter Without Venturi (다중회귀모형을 이용한 벤츄리가 없는 충격기류식 여과집진장치 압력손실 예측)

  • Suh, Jeong-Min;Park, Jeong-Ho;Cho, Jae-Hwan;Jin, Kyung-Ho;Jung, Moon-Sub;Yi, Pyong-In;Hong, Sung-Chul;Sivakumar, S.;Choi, Kum-Chan
    • Journal of Environmental Science International
    • /
    • v.23 no.12
    • /
    • pp.2045-2056
    • /
    • 2014
  • In this study, pressure drop was measured in the pulse jet bag filter without venturi on which 16 numbers of filter bags (Ø$140{\times}850{\ell}$) are installed according to operation condition(filtration velocity, inlet dust concentration, pulse pressure, and pulse interval) using coke dust from steel mill. The obtained 180 pressure drop test data were used to predict pressure drop with multiple regression model so that pressure drop data can be used for effective operation condition and as basic data for economical design. The prediction results showed that when filtration velocity was increased by 1%, pressure drop was increased by 2.2% which indicated that filtration velocity among operation condition was attributed on the pressure drop the most. Pressure was dropped by 1.53% when pulse pressure was increased by 1% which also confirmed that pulse pressure was the major factor affecting on the pressure drop next to filtration velocity. Meanwhile, pressure drops were found increased by 0.3% and 0.37%, respectively when inlet dust concentration and pulse interval were increased by 1% implying that the effects of inlet dust concentration and pulse interval were less as compared with those changes of filtration velocity and pulse pressure. Therefore, the larger effect on the pressure drop the pulse jet bag filter was found in the order of filtration velocity($V_f$), pulse pressure($P_p$), inlet dust concentration($C_i$), pulse interval($P_i$). Also, the prediction result of filtration velocity, inlet dust concentration, pulse pressure, and pulse interval which showed the largest effect on the pressure drop indicated that stable operation can be executed with filtration velocity less than 1.5 m/min and inlet dust concentration less than $4g/m^3$. However, it was regarded that pulse pressure and pulse interval need to be adjusted when inlet dust concentration is higher than $4g/m^3$. When filtration velocity and pulse pressure were examined, operation was possible regardless of changes in pulse pressure if filtration velocity was at 1.5 m/min. If filtration velocity was increased to 2 m/min. operation would be possible only when pulse pressure was set at higher than $5.8kgf/cm^2$. Also, the prediction result of pressure drop with filtration velocity and pulse interval showed that operation with pulse interval less than 50 sec. should be carried out under filtration velocity at 1.5 m/min. While, pulse interval should be set at lower than 11 sec. if filtration velocity was set at 2 m/min. Under the conditions of filtration velocity lower than 1 m/min and high pulse pressure higher than $7kgf/cm^2$, though pressure drop would be less, in this case, economic feasibility would be low due to increased in installation and operation cost since scale of dust collection equipment becomes larger and life of filtration bag becomes shortened due to high pulse pressure.

Pressure Drop Characteristics on HTS Power Cables with LN2 Flow (초전도 케이블 냉각유로에서의 압력강하 특성)

  • Koh Deuk-Yong;Yeom Han-Kil;Lee Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.81-86
    • /
    • 2006
  • High temperature superconducting (HTS) power cable requires forced sub-cooled LN2 flow cooling. Liquid nitrogen is circulated by a pump and cooled back by cooling system. Typical operating temperature range is expected to be between 65 K and 77 K. The HTS power cable needs sufficient cooling to overcome its low temperature heat load. For successful cooling, the hydraulic characteristics of the HTS power cable must be well investigated to design the cables. Especially, the pressure drop in the cable is an important design parameter, because the pressure drop decides the length of the cable, size of the coolant circulation pump and circulation pressure, etc. This paper describes measurement and investigation of the pressure drop of the cooling system. In order to reduce the total pressure drop of the cooling system, the flow rate of liquid nitrogen must be controlled by rotational speed of the circulation pump.