Browse > Article
http://dx.doi.org/10.5322/JES.2004.13.3.223

A Study on the Pressure drop Variance of Pulse interval, injection distance in Pulse Air Jet Type Bag Filter  

Seo, Jeong Min (밀양대학교 환경공학과)
Choe, Geum Chan (동아대하교 환경공학과)
Park, Jeong Ho (동아대학교 환경공학과)
Publication Information
Journal of Environmental Science International / v.13, no.3, 2004 , pp. 223-232 More about this Journal
Abstract
The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to $50mmH_2O$ varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/㎥ and 1g/㎥, the pressure $drop(\DeltaP)$ was stable 60 to 90minutes after operation. For the higher concentration of 3g/㎥, as $\DeltaP$ continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 1l0mm, when inlet dust concentration is 0.5g/㎥ or 1g/㎥, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/㎥ and 3g/㎥ has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.
Keywords
Pressure drop; Injection distance; Pulse interval; Concentration;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Properties, Behavior, and Measurement of Airborne Particles /
[ Hinds, W. C. ] / Aerosol Technology
2 여과 집집장치 기술의 최근동향 /
[ Tamori, I. ] / 첨담환경기술
3 Pulse-Jet식 여과포집진장치의 여과포 성능시험 연구(II) /
[ 박영옥;구철오;임정환;손재익 ] / 연구보고서
4 여과포 의한 coke 먼지 및 폐기물 유동층 소각먼지의 포집특성 /
[ 임전환;김홍용;구철오;박용오;양승목;박영성 ] / 대기환경공학회지
5 A Method for Investigating the Behaviour of Mechanically Shaken Filter Bags /
[ Helstrom, R. ] / Filtration & Separation   DOI   ScienceOn
6 Analysis of the Motion of Mechanically Shaken Filter Bags /
[ Li, X.;A. J. Chambers;R. Helstroom ] / Filtration & Separation   DOI   ScienceOn
7 Particle Collection by a Pulse-jet Fabric Filter /
[ Leith, D.;P. M. June ] / 68th Annual Meeting of APCA
8 충격기류식 여과집진설비에서 여과저항에 관한 연구 /
[ 서정민;김찬훈;박출재 ] / 한국폐기물학회지
9 전기력 이용한 배가스 처리기술의 동향 /
[ 최금찬 ] / 한국대기보전학회지
10 새로운 집진기술 동향 /
[ 김용진;정상현 ] / 한국대기보전학회지
11 /
[ Beitez, J. ] / process engineering and design for air pollution control
12 Collection efficiency as a function of particle size, shape, and density /
[ Dennis, R. ] / JAPCA
13 유연탄 활용에 따른 환경공해방지 대책연구(I) /
[ 손재익;김영성;박영옥;최정후;박영철;구철오;임정환 ] / 연구보고서, KE-90-17