Study of hydrodynamics and iodine removal by self-priming venturi scrubber

  • Jawaria Ahad;Talha Rizwan ;Amjad Farooq ;Khalid Waheed ;Masroor Ahmad ;Kamran Rasheed Qureshi ;Waseem Siddique ;Naseem Irfan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.169-179
    • /
    • 2023
  • Filtered containment system is a passive safety system that controls the over-pressurization of containment in case of a design-based accidents by venting high pressure gaseous mixture, consisting of air, steam and radioactive particulate and gases like iodine, via a scrubbing system. An indigenous lab scale facility was developed for research on iodine removal by venturi scrubber by simulating the accidental scenario. A mixture of 0.2 % sodium thiosulphate and 0.5 % sodium hydroxide, was used in scrubbing column. A modified mathematical model was presented for iodine removal in venturi scrubber. Improvement in model was made by addition of important parameters like jet penetration length, bubble rise velocity and gas holdup which were not considered previously. Experiments were performed by varying hydrodynamic parameters like liquid level height and gas flow rates to see their effect on removal efficiency of iodine. Gas holdup was also measured for various liquid level heights and gas flowrates. Removal efficiency increased with increase in liquid level height and gas flowrate up to an optimum point beyond that efficiency was decreased. Experimental results of removal efficiency were compared with the predicted results, and they were found to be in good agreement. Maximum removal efficiency of 99.8% was obtained.

Response of steel pipeline crossing strike-slip fault in clayey soils by nonlinear analysis method

  • Hadi Khanbabazadeh;Ahmet Can Mert
    • Geomechanics and Engineering
    • /
    • v.34 no.4
    • /
    • pp.409-424
    • /
    • 2023
  • Response of the pipeline crossing fault is considered as the large strain problem. Proper estimation of the pipeline response plays important role in mitigation studies. In this study, an advanced continuum modeling including material non-linearity in large strain deformations, hardening/softening soil behavior and soil-pipeline interaction is applied. Through the application of a fully nonlinear analysis based on an explicit finite difference method, the mechanics of the pipeline behavior and its interaction with soil under large strains is presented in more detail. To make the results useful in oil and gas engineering works, a continuous pipeline of two steel grades buried in two clayey soil types with four different crossing angles of 30°, 45°, 70° and 90° with respect to the pipeline axis have been considered. The results are presented as the fault movement corresponding to different damage limit states. It was seen that the maximum affected pipeline length is about 20 meters for the studied conditions. Also, the affected length around the fault cutting plane is asymmetric with about 35% and 65% at the fault moving and stationary block, respectively. Local buckling is the dominant damage state for greater crossing angle of 90° with the fault displacement varying from 0.4 m to 0.55 m. While the tensile strain limit is the main damage state at the crossing angles of 70° and 45°, the cross-sectional flattening limit becomes the main damage state at the smaller 30° crossing angles. Compared to the stiff clayey soil, the fault movement resulting 3% tensile strain limit reach up to 40% in soft clayey soil. Also, it was seen that the effect of the pipeline internal pressure reaches up to about 40% compared to non-pressurized condition for some cases.

A Study on Typhoon Impacts in the Nakdong River Basin Associated with Decaying Phases of Central-Pacific El Niño (중앙태평양 엘니뇨의 쇠퇴특성에 따른 낙동강 유역의 태풍영향 분석)

  • Kim, Jong-Suk;Son, Chan-Young;Lee, Joo-Heon;Moon, Young-Il
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.135-143
    • /
    • 2014
  • This study classified abnormal sea surface temperature changes of the central pacific region according to three evolution patterns. Focusing on typhoons that affect the Korean Peninsula, the research analyzed typhoon's occurrence spot and track, change in the central pressure characteristics, and the characteristics of change in typhoon precipitation and the number of occurrences of heavy rainfall in the Nakdong River Basin. As a result of analysis, in case of prolonged-decaying years and symmetric-decaying years, typhoon-related summer rainfall and heavy rainy days appeared to be higher than long-term average. But in case of abrupt-decaying years, the pattern of general decrease appeared. This is because typhoon's occurrence spot is located comparatively near the Korean peninsula, typhoon's central pressure is high, and typhoon's route generally moves to Japan. As the outcome, this study is expected to reduce flood damage through analyzing the characteristics of typhoon's activity according to CP El Ni$\tilde{n}$o evolution patterns and the characteristics of local typhoon rainfall. In addition, it is expected to provide useful information for establishing adaptation and mitigation to climate change.

Thermal-hydraulic behaviors of a wet scrubber filtered containment venting system in 1000 MWe PWR with two venting strategies for long-term operation

  • Dong, Shichang;Zhou, Xiafeng;Yang, Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1396-1408
    • /
    • 2020
  • Filtered containment venting system (FCVS) is one of the severe accident mitigation systems designed to release containment pressurization to maintain its integrity. The thermal-hydraulic behaviors in FCVSs are important since they affect the operation characteristics of the FCVS. In this study, a representative FCVS was modeled by RELAP5/Mod3.3 code, and the Station BlackOut (SBO) was chosen as an accident scenario. The thermal-hydraulic behaviors of an FCVS during long-term operation with two venting strategies (open-and-close strategy, open-and-non-close strategy) and the sensitivity analysis of important parameters were investigated. The results show that the FCVS can operate up to 250 h with a periodic open-and-close strategy during an SBO. Under the combined effects of steam condensation and water evaporation, the solution inventory in the FCVS increases during the venting phase and decreases during the intermission phase, showing a periodic pattern. Under this condition, the appropriate initial water level is 3-4 m; however, it should be adjusted according to the environment temperature. The FCVS can accommodate a decay heat power of 150-260 kW and may need to feed water for a higher decay heat power or drain water for a lower decay heat power during the late phase. The FCVS can function within an opening pressure range from 450 kPa to 500 kPa and a closing pressure range between 250 kPa and 350 kPa. When the open-and-non-close strategy is adopted, the solution inventory increases quickly in the early venting phase due to steam condensation and then decreases gradually due to the evaporation of water; drying-up may occur in the late venting phase. Decreasing the venting pipe diameter and increasing the initial water level can mitigate the evaporation of the scrubbing solution. These results are expected to provide useful references for the design and engineering application of FCVSs.

A Study on the Buckling Stability due to Lateral Impact of Gas Pipe Installed on the Sea-bed (해저면에 설치된 가스관의 외부충격에 의한 좌굴 안전성 검토)

  • Park, Joo-Shin;Yi, Myung-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.2
    • /
    • pp.414-421
    • /
    • 2022
  • Subsea oil and gas exploration is increasingly moving into deeper water depths, and typically, subsea pipelines operate under high pressure and temperature conditions. Owing to the difference in these components, the axial force in the pipe is accumulated. When a pipeline is operated at a high internal pressure and temperature, it will attempt to expand and contract for differential temperature changes. Typically, the line is not free to move because of the plane strain constraints in the longitudinal direction and soil friction effects. For a positive differential temperature, it will be subjected to an axial compressive load, and when this load reaches a certain critical value, the pipe may experience vertical (upheaval buckling) or lateral (snaking buckling) movements that can jeopardize the structural integrity of the pipeline. In these circumstances, the pipeline behavior should be evaluated to ensure the pipeline structural integrity during operation in those demanding loading conditions. Performing this analysis, the correct mitigation measures for thermal buckling can be considered either by accepting bar buckling but preventing the development of excessive bending moment or by preventing any occurrence of bending.

Reformability evaluation of blasting-enhanced permeability in in situ leaching mining of low-permeability sandstone-type uranium deposits

  • Wei Wang;Xuanyu Liang;Qinghe Niu;Qizhi Wang;Jinyi Zhuo;Xuebin Su;Genmao Zhou;Lixin Zhao;Wei Yuan;Jiangfang Chang;Yongxiang Zheng;Jienan Pan;Zhenzhi Wang;Zhongmin Ji
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2773-2784
    • /
    • 2023
  • It is essential to evaluate the blasting-enhanced permeability (BEP) feasibility of a low-permeability sandstone-type uranium deposit. In this work, the mineral composition, reservoir physical properties and rock mechanical properties of samples from sandstone-type uranium deposits were first measured. Then, the reformability evaluation method was established by the analytic hierarchy process-entropy weight method (AHP-EWM) and the fuzzy mathematics method. Finally, evaluation results were verified by the split Hopkinson Pressure Bar (SHPB) experiment and permeability test. Results show that medium sandstone, argillaceous sandstone and siltstone exhibit excellent reformability, followed by coarse sandstone and fine sandstone, while the reformability of sandy mudstone is poor and is not able to accept BEP reservoir stimulation. The permeability improvement and the distribution of damage fractures before and after the SHPB experiment confirm the correctness of evaluation results. This research provides a reformability evaluation method for the BEP of the low-permeability sandstone-type uranium deposit, which contributes to the selection of the appropriate regional and stratigraphic horizon of the BEP and the enhanced ISL of the low-permeability sandstone-type uranium deposit.

PASTELS project - overall progress of the project on experimental and numerical activities on passive safety systems

  • Michael Montout;Christophe Herer;Joonas Telkka
    • Nuclear Engineering and Technology
    • /
    • v.56 no.3
    • /
    • pp.803-811
    • /
    • 2024
  • Nuclear accidents such as Fukushima Daiichi have highlighted the potential of passive safety systems to replace or complement active safety systems as part of the overall prevention and/or mitigation strategies. In addition, passive systems are key features of Small Modular Reactors (SMRs), for which they are becoming almost unavoidable and are part of the basic design of many reactors available in today's nuclear market. Nevertheless, their potential to significantly increase the safety of nuclear power plants still needs to be strengthened, in particular the ability of computer codes to determine their performance and reliability in industrial applications and support the safety demonstration. The PASTELS project (September 2020-February 2024), funded by the European Commission "Euratom H2020" programme, is devoted to the study of passive systems relying on natural circulation. The project focuses on two types, namely the SAfety COndenser (SACO) for the evacuation of the core residual power and the Containment Wall Condenser (CWC) for the reduction of heat and pressure in the containment vessel in case of accident. A specific design for each of these systems is being investigated in the project. Firstly, a straight vertical pool type of SACO has been implemented on the Framatome's PKL loop at Erlangen. It represents a tube bundle type heat exchanger that transfers heat from the secondary circuit to the water pool in which it is immersed by condensing the vapour generated in the steam generator. Secondly, the project relies on the CWC installed on the PASI test loop at LUT University in Finland. This facility reproduces the thermal-hydraulic behaviour of a Passive Containment Cooling System (PCCS) mainly composed of a CWC, a heat exchanger in the containment vessel connected to a water tank at atmospheric pressure outside the vessel which represents the ultimate heat sink. Several activities are carried out within the framework of the project. Different tests are conducted on these integral test facilities to produce new and relevant experimental data allowing to better characterize the physical behaviours and the performances of these systems for various thermo-hydraulic conditions. These test programmes are simulated by different codes acting at different scales, mainly system and CFD codes. New "system/CFD" coupling approaches are also considered to evaluate their potential to benefit both from the accuracy of CFD in regions where local 3D effects are dominant and system codes whose computational speed, robustness and general level of physical validation are particularly appreciated in industrial studies. In parallel, the project includes the study of single and two-phase natural circulation loops through a bibliographical study and the simulations of the PERSEO and HERO-2 experimental facilities. After a synthetic presentation of the project and its objectives, this article provides the reader with findings related to the physical analysis of the test results obtained on the PKL and PASI installations as well an overall evaluation of the capability of the different numerical tools to simulate passive systems.

Interdecadal Variation of Tropical Cyclone Genesis Frequency over the Western North Pacific (북서태평양에서 열대 저기압 발생빈도의 십년간 변동 특성)

  • Choi, Ki-Seon;Kim, Baek-Jo;Lee, Seong-Lo;Park, Jong-Kil
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.6
    • /
    • pp.31-39
    • /
    • 2009
  • This study has found that there is a reverse phase with interdecadal variation in temporal variations of tropical cyclone (TC) genesis frequency (TCGF) between Northwest sector and Southeast sector, based on climatological mean tropical cyclone genesis location over the western North Pacific. The TCGF in the Northwest sector has been increased since the mid 1980s (1986-2005), while TCGF in the Southeast sector was higher until the early 1970s (1951-1970). The analysis of a difference between 1986-2005 and 1951-1970 showed results as follows: i) Through the analysis of vertical wind shear (VWS) and sea surface temperature (SST), less VWS and higher SST in the former (latter) period was located in the Northwest (Southeast) sector. ii) In the analysis of TC passage frequency (TCPF), TCs occurred in the Northwest sector frequently passed from east sea of the Philippines, through East China Sea, to Korea and Japan in the latter period, while TCs in the former period frequently has a lot of influences on South China Sea (SCS). In the case of TCs occurred in the Southeast sector, TCs in the west (east), based on $150^{\circ}E$ had a high passage frequency in the latter (former) period. In particular, TCs during the latter period frequently moved toward from the east sea of the Philippines to SCS and southern China. iii) This difference of TCPF between the two periods was characterized by 500 hPa anomalous pressure pattern. Particularly, anomalous cyclonic circulation strengthened over the East Asian continent caused anomalous southerlies along the East Asian coast line from the east sea of the Philippines to be predominate. These anomalous winds served as steering flows that TC can easily move toward same regions.

An Analysis of the Healing Effects of Forest Therapy and Horticultural Therapy (숲치유와 원예치료의 치유효과 분석)

  • Park, Sun-A;Jeong, Moon-Sun;Lee, Myungwoo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.3
    • /
    • pp.43-51
    • /
    • 2015
  • Stresses from desolate urban environments cause illnesses and worsen health conditions of urban residents, while natural environments have a positive influence on human. Natural healing programs such as forest therapy and horticultural therapy can be differentiated by the characteristic of activity space. However, previous studies of healing programs have focused on either forest therapy or horticulture therapy and there is a limit to comprehending the effects of adopting and connecting various healing programs. This study compares and analyzes the physiological and psychological effects of forest therapy and horticultural therapy to identify the effects and differences by types of healing programs. The before and after effects of horticultural therapy and forest therapy are measured by experiment and survey for 5 days with 5 subjects in each program. For physiological reaction, blood pressure, pulse, and cortisol levels are measured and the profile of moods states(POMS) is used to measure psychological reaction. Collected data are analyzed with the analysis of variance(ANOVA) and Paired-Sample T-test in SPSS 18.0. The results of this study are as follows: 1) forest therapy and horticultural therapy show positive effects in physiological and physiological aspects, 2) forest therapy is more effective than horticultural therapy in physiological relaxation and stress mitigation, 3) horticultural therapy has a tendency to alleviate depression more effectively than forest therapy. In conclusion, this study contributes to providing fundamental information for the development of healing programs and design guidelines for healing spaces through identifying the characteristics of each healing program.

A Study on the Risk Assessment of River Crossing Pipeline in Urban Area (도심지 하천매설배관의 위험성 평가에 관한 연구)

  • Park, Woo-Il;Yoo, Chul-Hee;Shin, Dong-Il;Kim, Tae-Ok;Lee, Hyo-Ryeol
    • Journal of the Korean Institute of Gas
    • /
    • v.24 no.2
    • /
    • pp.22-28
    • /
    • 2020
  • In this study, quantitative risk assessment was carried out for city gas high-pressure pipelines crossing through urban rivers. The risk assessment was performed based on actual city gas properties, traffic volume and population and weather data in the worst case scenario conditions. The results confirmed that the social and individual risks were located in conditionally acceptable areas. This can be judged to be safer considering that the risk mitigation effect of protecting the pipes or installing them in the protective structure at the time of the construction of the river buried pipe is not reflected in the result of the risk assessment. Also, SAFETI v8.22 was used to analyze the effects of wind speed and pasquil stability on the accident damage and dispersion distances caused by radiation. As a result of the risk assessment, the safety of the pipelines has been secured to date, but suggests ways to improve safety by preventing unexpected accidents including river bed changes through periodic inspections and monitoring.