• 제목/요약/키워드: Pressure level sensor

검색결과 126건 처리시간 0.025초

인솔형 국부 전단센서의 개발 및 보행 시 발바닥의 국부 전단력 측정 (A Development of an Insole Type Local Shear Measurement Transducer and Measurements of Local Plantar Shear Force During Gait)

  • 정임숙;안승찬;이진복;김한성;김영호
    • 한국정밀공학회지
    • /
    • 제22권6호
    • /
    • pp.213-221
    • /
    • 2005
  • An insole type local shear force measurement system was developed and local shear stresses in the foot were measured during level walking. The shear force transducer based on the magneto-resistive principle, was a rigid 3-layer circular disc. Sensor calibrations with a specially designed calibration device showed that it provided relatively linear sensor outputs. Shear transducers were mounted on the locations of four metatarsal heads and heel in the insole. Sensor outputs were amplified, decorded in the bluetooth transmission part and then transferred to PC. In order to evaluate the developed system, both shear and plantar pressure measurements, synchronized with the three-dimensional motion analysis system, were performed on twelve young healthy male subjects, walking at their comfortable speeds. The maximum peak pressure during gait was 5.00kPa/B.W at the heel. The time when large local shear stresses were acted correlated well with the time of fast COP movements. The anteroposterior shear was dominant near the COP trajectory, but the mediolateral shear was noted away from the COP trajectory. The vector sum of shear stresses revealed a strong correlation with COP movement velocity. The present study will be helpful to select the material and to design of foot orthoses and orthopedic shoes for diabetic neuropathy or Hansen disease.

공기압을 이용한 패드 변압기 침수방지용 장치 개발에 관한 연구 (The Development of Flood Protection System for Pad Transformer using Pneumatic Pressure)

  • 김기현;이상익;배석명;정찬웅;이재용
    • 전기학회논문지P
    • /
    • 제58권1호
    • /
    • pp.90-94
    • /
    • 2009
  • The inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. For diminishing flood damage of electrical equipment in the root, flood protection system which is used the basic frame of Pad transformer is developed using pneumatic pressure. This system is established on pressure generator equipment and sensor of flooded level operates at flooding occurrence and is maintained a shutting tightly structure. The system is able to protect indraft water in Pad Transformer and supply the electricity at emergency(flooding). And we tested safety for insulation resistance at flooding and applying an electrical current. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation by setting an example.

밸브누설 진단용 PZT 및 Pb-Free 음향센서의 압전특성 비교 연구 (Study on the Comparison of Piezoelectric Property of Acoustic Sensor for Valve Leak Diagnosis)

  • 이상국;박성근
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3383-3388
    • /
    • 2007
  • To compare the sensor performance of AE leak diagnosis system which can measure valve leak conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured on valve of the simulated test system for power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, pressure difference, valve size and fluid using both piezoelectric acoustic emission sensor and Pb-Free acoustic emission sensor. The results of this study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve.

  • PDF

The Effects of the Upright Body Type Exercise Program on Body Balance and Record of Archers

  • Kim, Dong-Kuk
    • 한국운동역학회지
    • /
    • 제28권1호
    • /
    • pp.9-18
    • /
    • 2018
  • Objective: This study aimed to analyze how the upright body type exercise program affected body balance and record of archers. This study aimed to prove the effectiveness of upright body type exercise, on this basis, in enhancing the performance of archery players. Method: A total of 14 archers (7 men and 7 women) in B Metropolitan City who had ${\geq}4years$ of career in archery and were given explanation of its contents and purpose before giving spontaneous consent to the experiment were enrolled in the study. The upright body type exercise program was implemented thrice a week for 12 weeks, with higher exercise intensity with time. A resistive pressure sensor, Gaitview AFA-50, was used to measure the foot plantar pressure distribution and analyze quantitative information concerning variation in posture stability and weight shift in dynamic balance of foot plantar pressure in shooting and static balance of plantar pressure with the eyes open and closed and the change in archery record accompanying the change in body balance. Results: As for the differences in foot plantar pressure between before and after participation in the upright body type exercise program, there was no significant difference in static balance of foot plantar pressure with the eyes open, and there was statistically significant difference at the ${\alpha}=.05$ significance level in static balance of foot plantar pressure with the eyes closed or in dynamic balance of foot plantar pressure in shooting. There was statistically significant difference at the ${\alpha}=.05$ significance level in archery record. Conclusion: The upright body type exercise program had positive effects on static and dynamic balance of foot plantar pressure by allowing archers to experience less body sway and physical imbalance in shooting with closed eyes and positive effects on archery record. Thus, the program is expected to help archers correct their posture and perform better.

높은 압력차의 유동모드 하에서 ER유체의 유변특성 (Rheological Characteristics of ER Fluids at High Pressure-Driven Flow Mode)

  • 이호근;최승복;정재천;강윤수;서문석
    • 유변학
    • /
    • 제11권1호
    • /
    • pp.1-8
    • /
    • 1999
  • 본 논문은 높은 압력차의 유동모드 하에서의 정상전단거동을 고찰하였다. ER유체 조성에 사용된 비전도성 용매는 10cS의 점도를 갖는 트랜스포머 오일이 사용되었으며, 전도성 입자의 중량비를 20 wt%와 30 wt%로 조절하여 입자 중량비에 대한 영향을 고찰하였다. 두 가지로 조성된 수계 ER유체를 ERF 1과 ERF 2로 칭하였으며, 성능 비교를 위하여 외국의 우수하다고 알려진 비수계 ER유체인 ERF 3를 사용한 실험도 실시하였다. 높은 압력차의 유동모드를 발생시키기 위해, 양방향 유압 실린더를 이용하여 고압의 질소 가스로 작동되는 실험 장치를 자체 제작하였다. 전극 앞에 장착된 압력 센서를 통해 전극 양단의 압력차를 구하고, 실린더 로드에 부착된 변위센서로부터 측정한 피스톤 속도를 유량 계산의 기초 자료로 사용하였다. 유동모드에 대한 유체역학적 해석을 통해 유도된 수식을 인용했으며, 위의 기초 자료와 수식을 이용하여 유동모드형 응용 장치에 적용하기 위한 전단변형률에 대한 전단응력의 결과를 도출하였다.

  • PDF

맥파 전달 속도(PWV) 측정을 위한 특징점 검출 알고리즘 개발 (Development of Feature Points Detection Algorithm for Measuring of Pulse Wave Velocity)

  • 최정현;조욱현;박준호;김남훈;성향숙;조종만
    • 센서학회지
    • /
    • 제20권5호
    • /
    • pp.343-350
    • /
    • 2011
  • The compliance and stiffness of artery are closely related with disease of arteries. Pulse wave velocity(PWV) in the blood vessel is a basic and common parameter in the hemodynamics of blood pressure and blood flow wave traveling in arteries because the PWV is affected directly by the conditions of blood vessels. However, there is no standardized method to measure the PWV and it is difficult to measure. The conventional PWV measurement has being done by manual calculation of the pulse wave transmission time between coronary arterial proximal and distal points on a strip chart on which the pulse wave and ECG signal are recorded. In this study, a pressure sensor consisting of strain gauges is used to measure the blood pressure of arteries in invasive method and regular ECG electrodes are used to record the ECG signal. The R-peak point of ECG is extracted by using a reference level and time windowing technique and the ascending starting point of blood pressure is determined by using differentiation of the blood pressure signal and time windowing technique. The algorithm proposed in this study, which can measure PWV automatically, shows robust and good results in the extraction of feature points and calculation of PWV.

Detecting of Periodic Fasciculations of Avian Muscles Using Magnetic and Other Multimedia Devices

  • Nakajima, Isao;Tanaka, Sachie;Mitsuhashi, Kokuryo;Hata, Jun-ichi;Nakajima, Tomo
    • Journal of Multimedia Information System
    • /
    • 제6권4호
    • /
    • pp.293-302
    • /
    • 2019
  • In the past, there was a theory that influenza wasn't transmitted directly from birds but was infected to humans via swains. Recently, molecular level research has progressed, and it was confirmed that the avian influenza virus can directly infected to human lung and intestinal epithelial cells. Three pandemicsin the past 100 years were also infected to humans directly from birds. In view of such scientific background, we are developing a method for screening sick birds by monitoring the physiological characteristics of birds in a contactless manner with sensors. Here, the movement of respiratory muscles and abdominal muscles under autonomic innervation was monitored using a magnet and Hall sensor sewn on the thoracic wall, and other multimedia devices. This paper presents and discusses the results of experiments involving continuous periodic noise discovered during flight experiments with a data logger mounted on a Japanese pheasant from 2012 to 2015. A brief summary is given as the below: 1. Magnet and Hall sensor sewn to the left and right chest walls, bipolar electrocardiograms between the thoracic walls, posterior thoracic air sac pressure, angular velocity sensors sewn on the back and hips, and optical reflection of LEDs (blue and green) from the skin of the hips allow observation of periodic vibrations(fasciculations) in the waves. No such analysis has been reported before. 2. These fasciculations are presumed to be derived from muscle to maintain and control air sac pressure. 3. Since each muscle fiber is spatially Gaussian distributed from the sympathetic nerve, the envelope is assumed to plot a Gaussian curve. 4. Since avian trunk muscles contract periodically at all time, we assume that the sympathetic nerve dominates in their control. 5. The technique of sewing a magnet to the thoracic wall and measuring the strength of the magnetic field with a Hall sensor can be applied to screen for early stage of avian influenza, with a sensor attached to the chicken enclosure.

무선센서 네트워크 기술 기반 액화가스 저장탱크 내 잔량 모니터링 시스템 구현 (Implementation of a Residual Quantity Monitoring System in a Liquefied Gas Storage Tank based on Wireless Sensor Network Technology)

  • 김민규;한해진;한재환
    • 센서학회지
    • /
    • 제27권5호
    • /
    • pp.352-356
    • /
    • 2018
  • This paper relates to a technology for monitoring a liquefied gas storage tank in the special gas field where demand is increasing owing to the continuous growth of related fields such as the semiconductor, display, and ICT convergence electronics industries. We have proposed a system for real - time monitoring using wireless sensor network technology, and implemented a system consisting of a sensor unit, transmitter module, and receiver module to be attached to a liquefied gas storage tank. The system was applied to LCO2 tanks among various liquefied gas storage tanks to verify the feasibility. The storage tanks employed in the experiments has capacities of 16,179 l and was 1,920 mm in inner diameter. Furthermore, the density was 1.03 g/l. The measured data were compared with reference data on the remaining gas level versus the $CO_2$ height of the surface, expressed using a conventional water meter, provided by an existing storage tank supplier. The experimental results show that the data is similar to the standard data provided by the tank supplier, and has a high accuracy and reliability within an error range of 0.03%.

Structural Studies of Thin Film Boron Nitride by X-ray Photoelectron Spectroscopy

  • 김종성
    • 센서학회지
    • /
    • 제5권1호
    • /
    • pp.51-56
    • /
    • 1996
  • Structural properties of rf sputtered boron nitride films were studied as a function of deposition parameters such as nitrogen pressure, substrate temperature and substrate bias using X-ray photoelectron spectroscopy and Auger electron spectroscopy. Composition and information on chemical bonding of resultant films was determined by XPS. XPS core level spectra showed that ratio of boron to nitrogen varied from 3.11 to 1.45 with respect to partial nitrogen pressure. Curve fitting of XPS spectra revealed three kinds of bonding mechanism of boron in the films. XPS peak positions of both B 1s and N 1s shifted to higher energy with higher nitrogen pressure as well as increase in substrate bias voltage. AES was used to see possible contamination of films by carbon or oxygen as well.

  • PDF

청각 피드백이 적용된 좌우 불균형 개선을 위한 밸런스 인솔 개발 및 검증 (The Development and Verification of Balance Insole for Improving the Muscle Imbalance of Left and Right Leg Using based Sound Feedback)

  • 강승록;윤영환;유창호;나재욱;홍철운;권대규
    • 재활복지공학회논문지
    • /
    • 제11권2호
    • /
    • pp.115-124
    • /
    • 2017
  • 본 연구에서는 하지의 좌우 불균형 검출을 위한 밸런스 측정 인솔을 개발하고 불균형을 개선하기 위한 청각 피드백 기술에 대한 검증을 하고자 하였다. 밸런스 인솔은 실시간 압력 감지 범위가 64 단계이며 발바닥 압력분포를 고려해 8개 부위에 FSR 센서를 탑재한 FPCB로 구성되었다. 피험자는 하지의 좌우 근력차이가 20% 이상 차이가 나는 피험자 20명을 선출하였다. 피험자들은 경사 0, 5, 10%와 속도 3, 4, 5km/h 로 15분 간 트레드밀 위에서 보행을 하였다. 또한 보행 시 나타나는 좌우 불균형을 평가 및 청각 피드백에 따른 개선효과를 검증하기 위해 측정된 족압 센서 데이터와 실시간 근육생리신호 데이터를 비교분석하였다. 실험 결과, 보행경사와 속도가 증가할수록 하지 좌우의 근력 불균형을 보유한 피험자들은 75.7%~140.9%까지 증가하는 반면 청각 피드백을 제공 시 10% 이내로 감소하는 결과를 보였다. 본 연구에서 개발 인솔 시스템을 이용한 보행환경에 따른 인체 좌우 불균형 발생시 FSR 신호 감도 결과와 인체생리신호 간 유효한 결과를 보였다. 향후 밸런스 피드백 보행 시 하지 좌우 불균형 개선 효과 경향을 보여 향후 족부 영역별 FSR 센서 민감도, 불균형 검출 및 개선을 위한 역치점 처리 알고리즘 개발에 대한 연구가 필요하다고 사료된다.