• Title/Summary/Keyword: Pressure difference

Search Result 3,895, Processing Time 0.48 seconds

Geometric Effects on Pressure Distribution in Mechanical Face Seals (기계평면시일의 기하학적 형태가 압력분포에 미치는 영향에 관한 연구)

  • 김청균;이일권
    • Tribology and Lubricants
    • /
    • v.5 no.2
    • /
    • pp.48-54
    • /
    • 1989
  • The effects of angular misalignment, coning and the temperature difference between the primary seal ring and the seal seat on the pressure distribution in mechanical face seals are analyzed. The modified Reynolds equation for the temperature dependent viscosity was solved by a finite difference approximation and Gauss-Seidel method. It is shown that the amplitude of pressure is significantly affected by the misalignment of the seals and a large temperature difference between the rotor and the stator.

A Study on the Window Glass Pressure for High-speed Train (고속철도차량의 유리창 압력에 관한 연구)

  • Kwon, Hyeok-Bin;Chang, Dae-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.4
    • /
    • pp.371-375
    • /
    • 2010
  • In order to decide the strength requirement of the window glass for the high-speed train, the pressure change during the passage of the EMU type high-speed train has been numerically simulated. Based on the calculation results, the pressure difference between the inner and outer pressure of the cabin has been calculated to yield the amount of load acting on the window glass of the cabin. To simulate the pressure field generated by the high-speed train passing through the tunnel, computational fluid dynamics based on the axi-symmetric Navier-Stokes equation has been employed. The pressure change inside a train has been calculated using first order difference approximation based on a linear equation between the pressure change ratio inside a train and the pressure difference of inside and outside of the train.

Numerical Study on the Effects of Velocity Profile Distortion and Swirl on Pressure Difference of Orifice Flowmeter Due to Pipe structure (배관구조에 따른 속도분포 변형과 선회가 오리피스 유량계의 압력차에 미치는 영향에 대한 수치적 연구)

  • Kim, Hong-Min;Kim, Kwang-Yong;Her, Jae-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.10
    • /
    • pp.1450-1456
    • /
    • 2003
  • Three-dimensional pipe flows with elbows, tees and headers in three different pipe systems are calculated to estimate the effect of asymmetry of axial velocity profile and swirl on measuring accuracy of an orifice flowmeter. It is evaluated how the pressure difference across the orifice is dependent on the upstream straight pipe length and how swirl intensity, swirl angle, and axial velocity distribution affect the measuring error of the orifice flowmeter. From the results, it is found that variation of the pressure difference across the orifice is negligible in case that maximum swirl angle is less than 2$^{\circ}$, and also that the pressure difference across the orifice is more sensitive to the asymmetry of axial velocity profile rather than the swirl intensity.

A Study on the Pressure Difference of Smoke Control Influence Factor in the Super High-rise Building (초고층 건물의 제연영향요소에 따른 수직피난공간 압력분포 시뮬레이션)

  • Choi, Seung-Hyuck;Lee, Dong-Yun;Jun, Hyun-Do;Lee, Dong-Yun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.130-135
    • /
    • 2009
  • These days, the super high-rise buildings construction plans are increased in Korea. But the stack effect in the super high-rise building interrupts the smoke control system's operation because of pressure difference, so it is more dangerous than the general building when firing. Therefore it needs to study about the pressure difference in the super high-rise buildings. We research the smoke control influence factor in the super high-rise building. Reflecting the influence factor, the simulation is practiced the case by case.

  • PDF

Endurance of Pneumatic Valve with a Multi-bender PZT Actuator (적층 벤더형 압전식 공압밸브의 내구 특성)

  • Yun, So-Nam;Park, In-Sub
    • Journal of Power System Engineering
    • /
    • v.18 no.2
    • /
    • pp.31-36
    • /
    • 2014
  • In this paper, pneumatic valve which consists of valve body, valve controller, nozzle and a multi-bender PZT actuator was suggested and fabricated. The fabricated pneumatic valve was experimented for performance evaluation. From the experimental results, we know that the flow rate of the suggested valve is 23 lpm at the pressure difference of 1bar and the maximum flow rate is 30 lpm at the pressure difference of 4 bar. The flow rates after endurance test of 9.8 million were 22.57 lpm and 28.62 lpm at the pressure difference of 1bar and 4bar, respectably. Finally, it was verified that the B10 life of the suggested pneumatic valve is over 50 million.

Differences of Foot Plantar Pressure Balance and Lung Capacity According to Change of Cervical Posture in Adults (경추 자세변화에 따른 성인의 족저압력 균형 및 폐활량의 차이)

  • Joo, Ha Young;Yang, Jeong Ok;Lee, Joong Sook
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.1
    • /
    • pp.93-101
    • /
    • 2020
  • Objective: The purpose of this study was to differences of foot plantar pressure balance and lung capacity according to cervical posture in adults. Method: The subjects consisted of 33 adults in their 20s and 50s who use M centers in B-gu and H-gu, B-City, and they measured foot plantar pressure balance and lung capacity according to cervical posture (cervical normal curvature posture, cervical flexural posture) in adults. Results: In this study, the difference of foot plantar pressure balance according to cervical posture were analyzed. In the difference between left and right foot pressure balance. It was 1.50% increased in the cervical flexural posture than in the cervical normal curvature posture, and a statistically significant difference was observed. In the difference between the anterior and posterior foot pressure balance. It was 4.28% increased in the cervical flexural posture than in the cervical normal curvature posture, and a statistically significant difference was observed. The difference of lung capacity according to cervical posture were analyzed. In the PEF, It was 58.63 l/min decreased in the cervical flexural posture than in the cervical normal curvature posture, and a statistically significant difference was observed. In the FEV1, It was 0.15 ℓ decreased in the cervical flexural posture than in the cervical normal curvature posture, and a statistically significant difference was observed. Conclusion: The results of this study suggest that had a positive effect on differences of foot plantar pressure balance and lung capacity at cervical normal curvature posture in adults. In future research, itis believed that research on the elderly who have collapsed the normal curvature posture due to aging, as well as teenagers whose normal curvature posture due to the use of smartphones, will contribute to the balance of foot pressure and improvement of the right cervical habits. In future studies, it is also believed that it will be necessary to measure lung capacity after performing exercise according to the cervical posture, thereby providing sufficient oxygen during exercise to enhance the persistence and efficiency of the movement.

An Analysis on the Major Parameter and the Relations of Pressure Difference Effect of Leakage Area in the Smoke-Control Zone (제연구역의 주요 매개 변수 및 누설 면적 변화를 고려한 차압 형성 관계 분석)

  • You, Woo Jun;Ko, Gwon Hyun;SaKong, Seong Ho;Nam, Jun-Seok;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.27 no.1
    • /
    • pp.20-25
    • /
    • 2013
  • This study is experimentally analyzed to extract the major parameters affecting the performance of the smoke-control system and the relations of pressure difference between vestibule and supply air pressure zone effect of supply mass flow rate and leakage area in the smoke-control zone. To obtain this, the mock-up building of three-story scale with a total of 10 compartments was constructed, and several apparatus were also installed for in-situ measurement of the ventilation flow rate, pressure difference between compartments, smoke defensive air velocity, the opening-closing force of door, etc. This article show that pressure difference in the smoke-control zone is significantly related with leakage area of vestibule in low pressure region, leakage area of supply air pressure in over pressure region and both of them in pressure control region when the pressure control range of damper is 45 Pa~55 Pa.

Experimental Study on Transformation of IPF and Pressure Drop in Branches with Ice Slurry (아이스슬러리의 분기관내 압력손실과 IPF 변화에 관한 실험적 연구)

  • 박기원;최현웅;노건상;정재천
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.2
    • /
    • pp.272-279
    • /
    • 2003
  • This study aimed to understand the effects of transporting ice slurry Particles through Pipes with branches. The experimental apparatus was constructed as ice slurry mixing tank. vortex pump, manometers for differential pressure measuring. IPF(ice packing factor) measuring instruments and branches as test sections. The experiments were carried out under various conditions. with concentration of water solution ranging between 0∼20wt% and velocity of water solution at the entry ranging between 1.5∼2.5m/s. The differential Pressure and IPF between the pipe entry and exit were measured. and flowing form was checked throughout the experiment. The pressure loss in 3d branches appeared compared with 6d branches so that it was very high. In the pressure loss of the inside and outside of branches. 6d branches was showed the difference. but was agreed in 3d branches The pressure loss according to concentration of water solution, low value appeared at 10wt% in 6d branches, at 20wt% in 3d branches. The pressure loss according to velocity, did not show large difference. The change of IPF at outlet, appeared +15∼-25% in 6d branches and 0∼-20% in 3d branches. The difference of IPF at the inside and outside of branches. appeared 10∼15% in 6d branches and maximum 5% in 3d branches.

Experimental Investigation for the Characteristics of Energy Separation of a Vortex Tube at Various Inlet and outlet Pressure Conditions (입.출구의 압력조건에 따른 보텍스 튜브의 에너지분리 특성에 관한 실험적 고찰)

  • 유갑종;김정수;최인수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.11
    • /
    • pp.1149-1155
    • /
    • 2001
  • The experimental investigation on energy separation in a vortex tube has been carried out to sow the effect of inlet and outlet pressures with various working fluids(air,$O_2,\;and\; CO_2$). Those outlet pressure means cold outlet and hot outlet pressure which were set equally. The results showed that the total enthalpy variation became a maximum when the mass flow rate at the cold outlet was a half of the total mass flow rate in the vortex tube (y=0.5). The total enthalpy variation was quite affected by the pressure difference between the inlet and outlet of vortex tube when the ratio of the inlet pressure to the cold outlet pressure remained constant. Although specific enthalpy differences between the inlet and the outlet (both cold and hot outlet) did not noticeably vary with the pressure difference, the specific enthalpy difference between the inlet and cold outlet was dominantly affected by physical properties of working gases.

  • PDF

The Study of the Mid-sole Wedge of Pronated Group on Maximum Force and Foot Pressure (중족부 Wedge 착용 시 회내 집단의 최대 힘과 족저압력 연구)

  • Lee, Jae-Ik;Lee, Hyo-Taek;Kim, Yong-Jae
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.337-344
    • /
    • 2010
  • This study was conducted on male college students with pronated foot to measure the foot pressure by having them wear three kinds of mid-sole wedge ($0^{\circ}$, $5^{\circ}$, $10^{\circ}$). Maximum force, foot contact area, mean pressure and peak pressure were measured using a foot pressure distribution measuring instrument. And the surface of the foot sole was divided into 10 areas. Regarding maximum force, there were statistically significant difference in the area 3 of the middle foot(p<.05). Regarding the foot contact area, it appeared broad in the outside area(1, 3, 5) of the foot according to mid-sole wedge, and there was statistically significant difference in the area 1 of the rear foot(p<.05) and the area 3 of the middle foot(p<.05). Mean pressure by foot area decreased in the inside of the foot according to mid-sole wedge, and there was statistically significant difference in the area 2 of the rear foot(p<.05) and the area 3 of the middle foot(p<.05). Regarding the peak pressure by foot area, the pressure roughly decreased in the inside area(2, 4, 7) of the foot according to mid-sole wedge, and there was statistically significant difference in the area 1(p<.05), 2(p<.05) of the rear foot and the area 3 of the middle foot(p<.05).