• 제목/요약/키워드: Pressure Reducing Valve

검색결과 91건 처리시간 0.025초

급수용 감압밸브의 비다이어프램 스템에서 압축스프링에 따른 유량 및 토출압력 효과 (Effects of Flow Rate and Discharge Pressure with Compressing Spring in Non-diaphragm Type Stem of Water Pressure Reducing Valve)

  • 변재욱;김치호;박성환;이명원;강명창
    • 한국기계가공학회지
    • /
    • 제18권5호
    • /
    • pp.103-109
    • /
    • 2019
  • The pressure reducing valve for water is controlled by the load of the compression spring and the force of the fluid acting on the diaphragm of the stem. Repeated upward and downward reciprocation of the pressure-reducing valve stem damages the diaphragm, resulting in leakage. In this study, we designed a stem without a diaphragm and adjusted the stiffness of the compressing spring. In order to select the spring stiffness, springs offering a stiffness of -20%, -10%, 0%, and 10% with respect to the stiffness of the compression spring attached to the existing pressure reducing valve stiffness. A prototype for the pressure reducing valve was fabricated and the pressure change was evaluated for the target static pressure (6 bar) by testing the pressure characteristics after mounting the modified stem and each compression spring. Evaluation of the pressure characteristics was carried out using ASSE 1003 and KS B 6153. In addition, the flow rates were compared by internal flow analysis of the conventional pressure reducing valve and the pressure reducing valve using the modified stems, and the flow analysis was performed using Solidworks flow simulation 2018. The spring stiffness was constantly discharged at the target static pressure of 3.793 kgf/mm, and the flow rate was increased by about 15% compared with the conventional pressure reducing valve.

비례감압밸브의 압력제어특성 (Pressure Control Characteristics of Proportional Pressure Reducing Valve)

  • 윤소남;함영복;조정대
    • 동력기계공학회지
    • /
    • 제7권1호
    • /
    • pp.68-73
    • /
    • 2003
  • The purpose of this study is to develop a new proportional pressure reducing valve and to verify the validity of a new mechanism with pressure control pin. The dynamic characteristics of the object pressure reducing valve was studied by numerical analysis of the mathematical model. Also, static and dynamic characteristics of the new pressure control valve were tested with a testing system based on the test standard.

  • PDF

감압밸브의 설계 및 유동해석 (Design and Computational Fluid Dynamics of Pressure Reducing Valve)

  • 이종선
    • 한국산학기술학회논문지
    • /
    • 제13권7호
    • /
    • pp.2853-2857
    • /
    • 2012
  • 본 논문은 급수 설비시스템의 적정수압을 유지하는 장치로 사용되는 감압밸브(Pressure Reducing Valve)의 구조와 특성을 알아보기 위해 3차원 자동 설계프로그램인 Solidworks를 활용하여 설계하였으며 현장에서 감압밸브의 제작을 위해 2차원 도면을 작성하였다. 또한 감압밸브내의 물의 흐름을 해석하기 위하여 3차원 유한요소해석 코드인 ANSYS를 사용하여 유동해석을 실시하였다.

현가시스템용 압력제어밸브에 관한 연구 (A Study on Hydraulic Pressure Reducing Valve for Active Suspension Systems)

  • 김동원;양승현;이석원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2528-2530
    • /
    • 2005
  • In this paper, a study on the analysis and design of an electro-hydraulic pressure reducing valve for active suspension system of car is fulfilled. Also, the structurally improved direct-acting electro-hydraulic pressure reducing valve is proposed to satisfy the performance that active suspension system requires. To prove the possibility whether the proposed valve can be used for active suspension system or not, the mathematical modeling and analysis for this valve is fulfilled and the experiment of response to controlled pressure is achieved. Here we conformed the response speed to controlled pressure of the structurally improved valve changed for the better by modifying the shape of spool such as the structure which make use of the power of controlled pressure derived from the area difference between two section areas of valve spool.

  • PDF

압력제어밸브를 통한 누수량의 추정과 활용 (Leakage Control and Application Using the Pressure Reducing Valve)

  • 김신걸;김윤환;김경필;구자용
    • 상하수도학회지
    • /
    • 제20권2호
    • /
    • pp.197-206
    • /
    • 2006
  • The leakage in the water distribution system means both the loss of money and water resource. To minimize the leakage, we introduced the pressure control method using the pressure reducing valve and pump schedule. For the pressure control, the total leakage is needed to divide into each node. In this study, EPANET 2.0 was used to simulate the water networks in two selected blocks after the total leakage was distributed with each node by four ways. The leakage was allocated into each node as water measured by meter, water pressure, water faucets and Lpcd and simulated by EPANET 2.0. Regardless of the leakage distribution ways, there was no significant difference between the measured water and the estimated water pressure. Thus, the leakage distribution way using water pressures estimated by simulation could be recommended. The scenarios controlling the pressure reducing valve and pump were made in two blocks(A and B). $86,713m^3/year$ leakage in the A block and $11,442m^3/year$ in the B block could be reduced as controlling the pressure reducing valve and pump schedule. It was shown that the fifty million won a year can be saved in the A block and 6.8 million won in the B block.

Low-Band Type 능동형 현가제어를 위한 직동식 전자비례 감압밸브의 개발 (Development of a Direct-Operated Proportional Pressure Reducing Valve for Low-Band Type Active Suspension Control)

  • 홍예선;류시복;김영식
    • 한국자동차공학회논문집
    • /
    • 제2권3호
    • /
    • pp.75-84
    • /
    • 1994
  • In general direct-operated pressure reducing valves have been gardly applied to a dynamic control system such as active suspension control because of their poor control stability. But they are more robust than pilot-operated type and do not need pilot control flow. In this paper development of a new direct-operated proportional pressure reducing valve for low-band type active suspension control is reported. By means of a special damper directly linked to the valve spool, the control stability could be effectively improved without drawback in response time. The linearity error was less than $\pm$3.5%. Applied to an experimental active suspension system the new valve showed the $-90^{\circ}$ phase delay at 4Hz with 20% sinusoidal signal input and could control the suspension system with almost same performance as that with a pilot-operated type valve.

  • PDF

구조-유체 연성해석을 통한 수도용 감압밸브에서의 유체유발진동에 관한 연구 (Study on Vibration Induced by Fluid at a Water Pressure Reducing Valve through Structure-Fluid Coupled Analysis)

  • 박우철;이중근;김일겸;박용석
    • 한국산학기술학회논문지
    • /
    • 제13권10호
    • /
    • pp.4371-4377
    • /
    • 2012
  • 본 논문에서는 수도용 감압밸브에서의 유체유발진동의 원인을 파악하기 위한 위하여 구조-유체 연성 해석을 수행하였다. 감압밸브의 소음을 측정한 결과 250Hz의 저주파 대역의 소음이 있음을 확인하였다. 상용 소프트웨어인 ANSYS/CFX를 사용하여 유체의 유동 해석을 수행한 결과, 감압밸브 내에서 노즐 효과에 의하여 40m/s 정도의 유속이 형성되고, 이에 따라 감압밸브 내에 부압이 발생하였다. 밸브 내에 형성된 유동에 의한 압력 분포를 하중 조건으로 구조해석을 한 결과, 유로를 막을 수 있을 정도의 고무 재질인 디스크의 변형이 발생하였다. 이러한 디스크의 변형이 반복적으로 일어남으로써 소음진동현상이 발생함을 확인하였다.

자동 균압 방지 감압밸브의 감압성능에 관한 연구 (The Performance of a New Pressure Reducing Valve Automatically Preventing Pressure Equalization)

  • 박용환;김상욱;김범규
    • 한국화재소방학회논문지
    • /
    • 제27권1호
    • /
    • pp.26-30
    • /
    • 2013
  • 초고층건물의 수계소화설비에 있어서 적정 방수압력을 제공하기 위해서는 감압밸브의 사용이 필수적이다. 하지만 많은 경우 밸브 내 누설로 인한 균압 현상으로 인해 감압 기능을 상실하는 경우가 많다. 본 연구에서는 최근 개발된 균압 현상을 자동으로 방지해 줄 수 있는 새로운 개념의 감압밸브에 대한 성능평가를 수행하였다. 그 결과 다양한 설정 조건에도 불구하고 설계 감압비가 최대 약 11% 범위 내에서 유지되었으며, 피스톤의 자동 셀프 록(self-lock) 기능에 의해 균압 현상도 방지할 수 있는 것으로 나타났다.

감압밸브를 사용한 탄광갱내 공조용 냉수 공급시스템의 과도현상 해석 (Simulation of Transient Flow in a Cold-Water Supply System with Pressure Reducing Valves for Cooling the Inside of a Coal Mining Pit)

  • 강신형;이택식;이상산
    • 대한설비공학회지:설비저널
    • /
    • 제17권4호
    • /
    • pp.395-407
    • /
    • 1988
  • Transient flow in a cold-water supply system for cooling the inside of a coal mining pit was numerically simulated. Properly designed and presetted pressure reducing valves control the level of pressures of the piping system at normal or emergent conditions Quasi-steady relations to simulate the valve motion are obtained and the transient performance of the valve is investigated in the present paper. The present method reasonably simulate transient phenomena in the system including the pressure reducing valve. Excessive valve motion and column separation are simulated when the flow is abruptly reduced. A calculated example of the real system is also presented. The simulation can be used for the safety-check and the guidance for design and operation in emergent cases of the system.

  • PDF