Performance test and uncertainty analysis of the FBG-based pressure transmitter for liquid metal system

  • Byeong-Yeon KIM;Jewhan LEE;Youngil CHO;Jaehyuk EOH;Hyungmo KIM
    • Nuclear Engineering and Technology
    • /
    • v.54 no.12
    • /
    • pp.4412-4421
    • /
    • 2022
  • The pressure measurement in the high-temperature liquid metal system, such as Sodium-cooled Fast Reactor(SFR), is important and yet it is very challenging due to its nature. The measuring pressure is relatively at low range and the applied temperature varies in wide range. Moreover, the pressure transfer material in impulse line needs to considered the high temperature condition. The conventional diaphragm-based approach cannot be used for it is impossible to remove the effect of thermal expansion. In this paper, the Fiber Bragg Grating(FBG) sensor-based pressure measuring concept is suggested that it is free of problems induced by the thermal expansion. To verify this concept, a prototype was fabricated and tested in an appropriate conditions. The uncertainty analysis result of the experiment is also included. The final result of this study clearly showed that the FBG-based pressure transmitter system is applicable to the extreme environment, such as SFR and any other high-temperature liquid metal system and the measurement uncertainty is within reasonable range.

The Effects of Temporary Visual Block on the Foot Pressure and Foot Area of Chronic Stroke Patients (일시적인 시각차단이 만성 뇌졸중 환자의 지면 족저압 분포와 족부면적에 미치는 영향)

  • Jeong, Seong-Hwa;Koo, Hyun-Mo
    • PNF and Movement
    • /
    • v.17 no.1
    • /
    • pp.103-109
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the effect of temporary visual block existence and nonexistence on the change in foot pressure and foot area in stroke patients. Methods: Sixty-one chronic stroke patients volunteered to participate in the study. Foot pressure and foot area were measured using the Biorescue system. The subject maintain a comfortable standing position on the pressure-measuring plate one meter away from the computer. The sequence of the visual variation data while standing on the measuring plate was collected randomly. The data were collected with three repetitions and used the five-second measuring values except the first second and the last second according to each visual condition. All data were analyzed using SPSS version 21.0. The significance level for the statistical inspection was set as 0.05. Results: The comparison between the visual existence and nonexistence status showed statistically significant effects on foot pressure and foot area. The visual nonexistence status showed more improvement in foot pressure symmetry and area than visual existence status. Conclusion: This study shows that the foot pressure and foot area for the chronic stroke patients changed according to the visual states. It is predicted that these data will be used in rehabilitation training programs and to present temporary changes in visual status for stroke patients.

Development of pressure measuring system for powered-wheelchair (전동휠체어 압력분포 측정시스템 개발)

  • Kil, S.K.;Lee, S.C.;Kim, T.W.;Hwang, J.H.;Hong, E.P.;Han, Y.H.;Lee, J.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.2
    • /
    • pp.109-115
    • /
    • 2013
  • In this paper, we developed pressure mesuring system for powered wheelchair and tried to validate the usefulness of developed system by pressure measuring experiment with 3D motion analysis. This system consist of 64ch seat FSR(Force Sensitive Resistance) sensor unit, 30ch*2 armchair FSR sensor unit, analog and digital hardware board, 2ch rotary encoder unit and realtime signal processing & display S/W. And each data acquired from this system has sampling frequency of 12bit, 10Hz. Pressure measuring experiment for 10 persons who use wheelchair in real life was performed in the 3D vision analysis room. From the experiment, we obtained result that the center line of body inclined to outside direction during powered-wheelchair rotate any direction.

  • PDF

Development of high sensitivity pressure sensor using optical fiber (광섬유를 이용한 고감도 압력센서 개발)

  • 이권형;조경재;김현철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.478-481
    • /
    • 1995
  • This paper presents the system demonstrator for an optical fiber sensor system developed as a technological evaluator suitable for generic sensric sensing applications. The new type of fiber-optic sensor employed a diaphragm displacement transforms pressure into optical intensity. Form this sensing technique, we can know the variation of source intensity, the loss of a optical fiber, and the reflectivity of the diaphragm surface. Experimental results are applied to the low-pressure transducer suitable for measuring miniature pressure.

  • PDF

Development of the Deflection Measuring System by Pressure Gage for a Floating Dock (압력게이지를 이용한 부유식 도크의 변형 계측시스템 개발)

  • Kim, Youngbok
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.2
    • /
    • pp.90-95
    • /
    • 2017
  • In case of working for the construction of blocks of any ship in a floating dry dock, there may exist deflection in the pontoon deck of the floating dock due to the ballast loading and the self weight of the ship and the floating dock. This paper is on the development of the measuring system and the GUI program to show the real time variation of the deflections at even-spaced positions by several pressure gages and the calculated inclination of the floating dock. The measured and calculated data produced by this developed system could be used to prepare the protection plan on site like ballast adjustment to ensure the safety of working during the floating dock operation.

Implementation of Noninvasive Blood Pressure Measuring System for Home Health Care Using Oscillometric Method (오실로메트릭법을 적용한 홈헬스케어용 비침습적 혈압측정법의 구현)

  • Kang Seong-Chul;Jeon Gye-Rock;Jeong Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.689-692
    • /
    • 2006
  • In this study, an implementation of a system for measuring more accurate blood pressure by non-invasive methods of oscillometric was performed to reduce errors and weaknesses of the existing invasive blood pressure measurement methods. The system is composed of pressure control, signal measurement and blood pressure signal processing units. To verify the validity of the system, tests of characteristics evaluations for pressure measurement unit, extraction of characteristic ratios for blood pressure estimation, blood pressure tracking by oscillometric method were performed. A group of five adult male was selected for the clinical test of the implemented system. The results of the oscillometric method in comparison with auscultatory method are that the maximum ratios of PAD of average, systolic and diastolic arterial pressure are 1.38%, 1.63% and 2.97% with SEP of 5.00, 3.72 and 4.34.

  • PDF

Estimating blood pressure using the pulse transit time of the two measuring from pressure pulse and PPG

  • Kim, Gi-Ryon;Ye, Soo-Young;Kim, Jae-Hyung;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2008
  • Blood pressure (BP), one of the most important vital signs, is used to identify an emergency state and reflects the blood flow characteristics of the cardiovascular system. The conventional noninvasive method of measuring BP is inconvenient because patients must wear a cuff on their arm and the measurement process takes time. This paper proposes an algorithm for estimating the BP using the pulse transit time (PTT) of the photoplethysmography (PPG) and pressure pulse from finger at the same time as a more convenient way to measure the BP. After recording the electrocardiogram (ECG), measuring the pressure pulse, and performing PPG, we calculated the PTT from the acquired signals. Then, we used a multiple regression analysis to measure the systolic and diastolic BP indirectly. Comparing the BP measured indirectly using the proposed algorithm and the real BP measured with a sphygmomanometer, the systolic pressure had a mean error of ${\pm}3.240$ mmHg and a standard deviation of 2.530 mmHg, while the diastolic pressure had a satisfactory result, i.e., a mean error of ${\pm}1.807$ mmHg and a standard deviation of 1.396 mmHg. These results are more superior than existing method estimating blood pressure using the one PTT and satisfy the ANSI/AAMI regulations for certifying a sphygmomanometer i.e., the measurement error should be within a mean error of ${\pm}5$ mmHg and a standard deviation of 8 mmHg. These results suggest the possibility of applying our method to a portable, long-term BP monitoring system.

A Study on Development of Marine Tank Monitoring System (선박용 탱크 모니터링 시스템 개발에 관한 연구)

  • Weon, La-Kyoung;Rhyu, Keel-Soo;Kim, Joo-Won;Seong, Chang-Gyu;Park, Jong-Il;Kim, Tai-Jin
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.65-66
    • /
    • 2006
  • As industrial technology recently, a field of marine engineering is demanding integration and manless system. In this study, tank monitoring system is developed, which is able to watch real-time the marine tank for measuring a level, pressure, temperature. The system will provide efficiently measuring data for operator.

  • PDF

Development of Plantar Pressure Measurement System and Personal Classification Study based on Plantar Pressure Image

  • Ho, Jong Gab;Kim, Dae Gyeom;Kim, Young;Jang, Seung-wan;Min, Se Dong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.11
    • /
    • pp.3875-3891
    • /
    • 2021
  • In this study, a Velostat pressure sensor was manufactured to develop a plantar pressure measurement system and a C#-based application was developed to monitor and collect plantar pressure data in real time. In order to evaluate the characteristics of the proposed plantar pressure measurement system, the accuracy of plantar pressure index and personal classification was verified by comparing with MatScan, a commercial plantar pressure measurement system. As a result, the output characteristics according to the weight of the Velostat pressure sensor were evaluated and a trend line with the reliability of r2 = 0.98 was detected. The Root Mean Square Error(RMSE) of the weighted area was 11.315 cm2, the RMSE of the x coordinate of Center of Pressure(CoPx) was 1.036 cm and the RMSE of the y coordinate of Center of Pressure(CoPy) was 0.936 cm. Finally, inaccuracy of personal classification, the proposed system was 99.47% and MatScan was 96.86%. Based on the advantage of being simple to implement and capable of manufacturing at low cost, it is considered that it can be applied to various fields of measuring vital signs such as sitting posture and breathing in addition to the plantar pressure measurement system.