• Title/Summary/Keyword: Prefabricated

검색결과 477건 처리시간 0.173초

프리스트레스트 프리캐스트 더블 티형보의 최적설계 (Design and Optimization of Prestressed Precast Double-tee Beams)

  • 유승룡;민창식
    • 콘크리트학회논문집
    • /
    • 제11권6호
    • /
    • pp.57-67
    • /
    • 1999
  • Optimization scheme is presented for the design of precast prestressed double-tee beams used as slabs in the parking or market structures. The objective considered is defined by a function that minimizes the hight of the double-tee beam, including the prefabricated element and the concrete topping poured in a second phase. The Sequential Quadratic Programming method is adopted to solve the problem. As an example 12 double-tee beams are designed with the design loads of the current design code of our country. The results from optimization process show that at least 29cm less in overall height than that designed by PCI design handbook. The section determined from the optimization process was refined for practical considerations. A MathCad 7.0 Pro Spreadsheet was prepared to verify all ACI requirements for flexure, shear and deflections. Flexural tests are performed on four full-scale 12.5m prototype models and show that all the specimens are fully comply the flexural strength requirements as specified by ACI 318-95. The present optimization scheme can be used for wider application of the design of precast prestressed double-tee beams with different materials and configurations particularly for in a large scale or for important designs.

국부의치 설계에 관한 임상적 연구 (A CLINICAL EVALUATION ON THE DESIGN OF REMOVABLE PARTIAL DENTURE)

  • 장익태
    • 대한치과보철학회지
    • /
    • 제14권1호
    • /
    • pp.66-71
    • /
    • 1976
  • The purpose of this investigation was to evaluate the mouth preparation and design of removable partial dentures. A total of 187cases for the prefabricated partial denture frameworks in both maxillary and mandibular semi-dentulous situations (66 cases and 203 cases) was selected from this study. The evaluations of mouth preparation and design observed here involved the classification of edentulous spaces, status of abutment splinting with location, design of direct retainer and structure of maxillary major connector according to the incidence of both dental arches, ages, sexes and segment of semidentulousness. The analyzed results were as follows: 1) The order of frequency rate in removable partial denture construction was Class II (50.27%), Class I (36. 90%), Class III (10.69%), and Class IV (2.14 %). 2) The distribution on design of maxillary removable partial denture prosthesis was 33.22% and 64.11% in mandibular removable partial denture prosthesis. 3) The age distribution of removable partial denture prosthesis was prominent after40 years (41.71%). 4) The design pattern of maxillary major connectors was in order of anteroposterior bar, single palatal bar, palatal strap, U-shape connector. 5) The design pattern of direct retainer was in order of Aker's clasp, I-bar clasp, backaction clasp, cuspid universal clasp. 6) The abutment for partial denture clasp splinted between premolar and premolar and its frequency rate revealed 53.44%. 7) It seemed that the location and design of the indirect retainer showed accepatble limit.

  • PDF

Frontal augmentation as an adjunct to orthognathic or facial contouring surgery

  • Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제38권
    • /
    • pp.37.1-37.5
    • /
    • 2016
  • Background: The dimensions and shape of the forehead determine the esthetics of the upper third of the face. Korean young people consider a broad and smooth, rounded forehead more attractive. As a result, frontal augmentation becomes more popular in patients with dentofacial deformities. Various surgical procedures and materials have been used in frontal augmentation surgery, with associated advantages and disadvantages. Silicone is a good candidate for frontal augmentation. The author presents two cases of esthetic frontal augmentation with a prefabricated silicone implant in female patients with dentofacial deformities. Case presentation: In case 1, a 24-year-old female patient underwent frontal augmentation surgery with simultaneous maxillomandibular and zygomatic osteotomies to correct facial asymmetry. A silicone implant was fabricated preoperatively using a positive template stone mold of her forehead. In case 2, a 23-year-old female patient underwent total facial contouring surgery including frontal augmentation for improved facial esthetics. A computed tomography (CT)-guided rapid prototype (RP) model was used to make the silicone implants. The operative procedure was safe and simple, and the silicone implants were reliable for a larger degree of frontal augmentation. Six months later, both patients had recovered from the surgery and were satisfied with their frontal shape and projection. Conclusions: Frontal augmentation with silicone implants can be an effective adjuvant strategy to improve facial esthetics in patients with a flat and narrow forehead who undergo orthognathic reconstruction or total facial contouring surgery.

동수경사 변화에 따른 연직배수재의 통수능 (Discharge Capacity for Vertical Drain Boards with Hydraulic Gradient Variation)

  • 김주형;이광우;조삼덕;장갑식
    • 한국지반신소재학회논문집
    • /
    • 제9권2호
    • /
    • pp.11-20
    • /
    • 2010
  • 본 연구에서는 국내에서 사용하고 있는 연직배수재의 통수능시험 평가방법과 국내 관련 시방기준들을 고찰하고 연직배수재통수능 시험시 결과에 영향을 미치는 인자로 동수경사 변화에 따른연직배수재의 통수능 시험 결과를 분석하였다. 국내 연직배수재의 통수능 평가시험방법으로 기존 Delft 방법에 근거한 KS K 0940(2008)이 최근 한국표준으로 등재되었으며, 이 시험방법을 사용하는 경우 동수경사의 변화에 따라 연직배수재의 통수능의 차이가 크게 나타날 가능성이 있는 것으로 확인되었다.

  • PDF

방사선 조사된 상악골에서 all-on-4 임플란트에 의해 지지되는 지르코니아 고정성 보철물 수복 증례 (Zirconia ceramic fixed dental prosthesis with all-on-4 concept implants for irradiated maxilla: A case report)

  • 최은주;조혜원
    • 대한치과보철학회지
    • /
    • 제55권2호
    • /
    • pp.218-224
    • /
    • 2017
  • 방사선치료를 받은 상악에 임플란트 지지 고정성 보철물을 이용하여 수복하는 것은 골치유능력이 낮기 때문에 상세한 치료계획이 필요하다. All-on-4 개념에 의한 임플란트 식립은 골이식을 피하면서 임플란트를 매식할 수 있어 유리하다. 일반적으로 경사된 임플란트에는 기성 경사형 지대주를 사용해왔다. 본 임상증례에서는 computer-aided design and computer-aided manufacturing (CAD/CAM)으로 제작된 지대주를 사용하였다. 본 증례는 all-on-4 개념에 의해 임플란트를 매식하고 CAD/CAM titanium 지대주를 제작한 다음 CAD/CAM zirconia 고정성 보철물로 수복하여 좋은 결과를 얻었기에 보고하고자 한다.

RTA가구의 특성과 세미나 테이블 개발에 관한 연구 (A Study on the Characteristics of RTA Furniture and Development of Seminar Table)

  • 이낙현;김미숙
    • 한국가구학회지
    • /
    • 제28권4호
    • /
    • pp.259-267
    • /
    • 2017
  • Furniture should change according to space. Therefore, it is important that the flexibility of the furniture, the functional efficiency, the economical efficiency and the convenience of the furniture of today. These characteristics are also important for seminar tables that are used temporarily by a large number of people. The seminar furniture currently in use has no shielding plate, there are two forms of table and shielding plate folding table. Therefore, in this research, furniture design and product development that can complement the shortcomings of the seminar furniture currently in use were done. Analysis of problems through overseas investigation and domestic market research, design planning and design, and prototyping. We have sought to optimize the volume by applying the characteristics of RTA furniture to develop a lightweight, lightweight, lightweight, easy to install and easy to use shielding plate, and open and closed system. Basically developed two types of shielding board seminar table basic shape and Roll Screen type, we expanded the scope of application such as each color and pattern. In order to reduce the weight, we replaced the parts such as anchor bolts and hinges and the shielding plate with Roll Screen and pursued volume optimization. As a result of this research, it is expected that the system of mechanisms such as packaging standardization and damage prevention for weight reduction and volume optimization will contribute to building competitiveness by domestic office prefabricated furniture industry's original technology.

실리콘 보형물을 이용한 척추측만증 배부 윤곽변형 교정수술 (Correction of the Dorsal Contour Deformity Caused by Scoliosis with Silicone Implant)

  • 박지웅;조상헌;신종인;김창연
    • Archives of Plastic Surgery
    • /
    • 제34권6호
    • /
    • pp.792-795
    • /
    • 2007
  • Purpose: Scoliosis is a multifactorial disorder caused by genetic, biochemical, developmental, neuromuscular factors and causes complex deformities which include skeletal deformity, pain, cardiovascular dysfunction, motor function disorder. Until now, the treatment of scoliosis have been focused on orthopedic correction, preservation of cardiopulmonary and neurologic function. But recently, as aesthetic demands increases, the needs for the correction or improvement of the trunk and extremity contour does. So, the correction of soft tissue contour deformity can be a new concept for the treatment of scoliosis. Methods: We corrected a deformed contour with prefabricated silicone implant in a scoliosis patient who had been operated for orthopedic correction previously. Submuscular pocket was made under trapezius and latissimus dorsi muscle. Silicone implant was placed in the pocket and fixed to thoracolumbar fascia with sutures. Results: We had a satisfactory results for the correction of contour deformity. There was no significant complication. Conclusion: Silicone implant is a new trial for the correction of scoliosis contour deformity. This method is simple, safe and brings on satisfactory results.

Sound transmission of lightweight block walls and panels-Theory and Experiments

  • S Kandaswamy;A Ramachandraiah
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 춘계학술발표대회 논문집 제23권 1호
    • /
    • pp.235-239
    • /
    • 2004
  • Sound transmission either as airborne or structure borne is a potential problem that occurs in buildings either from sources within or from outside. With the expansion of real estate activities in countries like India, the need to attend sound insulation requirements also assumes greater dimensions. The focus of this research is on studying the sound transmission characteristics of building structures made of hollow blocks, neocrete block, aerocon block and prefabricated panels such as Ferrocement panel. The tests were carried out the blocks with and without plastering and their sound reduction index was measured at one-third octave frequencies. In the case of ferrocement panels, different types of systems were tested in the TL suite. Panels with cavity, with cavity ties, with insulation, with stiffeners and with plasterboard were investigated. Sound reduction index of these panels was measured with additional quantities like longitudinal wavespeed, and loss factors (internal and total loss factor). Tests were also conducted on Cypcrete wall panel and Sandwiched wooden panel in a similar way. Theoretical investigations were carried out using Statistical Energy Analysis (SEA) for the above systems. Sound reduction index was then compared between the predicted and the measured values.

  • PDF

제1기계시대 건축디자인에서의 운동의 표현에 관한 연구 (A Study on the Expression of Movement in Architectural Design in the first Machine Age)

  • 김원갑
    • 한국실내디자인학회논문집
    • /
    • 제14권1호
    • /
    • pp.28-36
    • /
    • 2005
  • The theme of modern architecture was various expression of dynamism and the flow of space. It was because that the space become the main theme of architecture since the late 19th century, and the space was changed from the 3rd dimension into the 4th dimensional space-time continuum. Though many avant-garde artists in the early 20th century did not understand the theory of relativity, they became conscious of the concept of space-time continuum, and tried to express the movement as the duration in time which Bergson defined. Many architects in the first machine age conceived the movement of architecture, and understand it as the dynamism of the mass and in the space. But especially, Sant'Elia and Hilberseimer expressed it as the flow of various force and vector In the metropolis as entire system. And Some architects conceived it as real movement of the building and expressed it as the rotary motion of building, movable partition and furniture, mobile prefabricated building. This study analyzed the expression of movement in architecture in the first machine age.

Experimental study on a new type of assembly bolted end-plate connection

  • Li, Shufeng;Li, Qingning;Jiang, Haotian;Zhang, Hao;Yan, Lei;Jiang, Weishan
    • Steel and Composite Structures
    • /
    • 제26권4호
    • /
    • pp.463-471
    • /
    • 2018
  • The bolted end-plate beam-column connections have been widely used in steel structure and composite structure because of its excellent seismic performance. In this paper, the end-plate bolted connection is applied in the concrete structure, A new-type of fabricated beam-column connections with end-plates is presented, and steel plate hoop is used to replace stirrups in the node core area. To study the seismic behavior of the joint, seven specimens are tested by pseudo-static test. The experimental results show that the new type of assembly node has good ductility and energy dissipation capacity. Besides, under the restraint effect of the high-strength stirrup, the width of the web crack is effectively controlled. In addition, based on the analysis of the factors affecting the shear capacity of the node core area, the formula of shear capacity of the core area of the node is proposed, and the theoretical values of the formula are consistent with the experimental value.