• Title/Summary/Keyword: Precision-amplifier

Search Result 91, Processing Time 0.035 seconds

Machining of Anode and Cavity applying Ultraprecision Machining Characteristics of OXFC (무산소동의 초정밀 절삭 특성을 이용한 아노드 및 캐비티의 가공)

  • 원종호;김주환;박순섭;김건희;김상석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.922-925
    • /
    • 2002
  • Klystron which is micro wave amplifier tube are mainly used in fields of science such as accelerator, nuclear fusion, broadcasting, communication fields, and defense industry fields, tract. The quality of Klystron anode and cavity are determined by form accuracy and roughness of the worked surface. Therefore anode and cavity are restricted the from accuracy strictly and the surface roughness be under Rmax 0.03S. As a work material of anode and cavity, the oxygen-free copper, that is used for optical pares of aerospace and laser mirror is selected. An outside diameter of material is $\Phi$100 mm and an inside diameter is $\Phi$30~33 mm. In this study, to find the optimum ultra precision cuffing condition of oxygen-free copper with diamond turning machine, the surface roughness is examined for various diamond toot nose radius, main spindle speed, fred rate and depth of cut. As a result of experiment, we could machined the anode and cavity with a surface roughness within Ra 3.2 nm, a form accuracy within 0.01 $\mu\textrm{m}$.

  • PDF

Computer Simulation and Control Performance Evaluation for Feedback System of Ultra Positioning by using Laser Interferometer (Laser Interferometer를 이용한 초정밀위치결정 피드백시스템의 컴퓨터 시뮬레이션 및 제어성능 평가)

  • 김재열;이규태;곽이구;한재호;김창현
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.11 no.1
    • /
    • pp.17-25
    • /
    • 2002
  • This system is composed of fine and coarse apparatus, measurement system and control system. Piezoelectric actuator is designed far fee positioning. We make a study of precision apparatus that is used in the various industrial machine. The study was carried out to develope a precision positioning apparatus, consisting of servo motor and piezoelectric actuator Coarse positioning using lead screw is thrived by servo motor. Control system output a signal from laser interferometer to amplifier of servo motor and piezoelectric actuator after digital signal processing (DSP). Resolution of this apparatus measure with laser interferometer. In this study, design method and control system with ultra precision position apparatus are researched. As the first step, we have estimated for control performance and system stability before an actual apparatus is manufactured by MATLAB with SIMUUNK including various frictions those are composed of pre-design and system modeling.

A Study for Application of Active Magnetic Bearing using Quantitative Feedback Theory (Quantitative Feedback Theory를 이용한 능동 자기베어링의 적용 연구)

  • Lee, Gwan-Yeol;Lee, Hyeong-Bok;Kim, Yeong-Bae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.107-115
    • /
    • 2001
  • Most of rotating machineries supported by contact bearing accompany lowering efficiency, vibration and wear. Moreover, because of vibration, which is occurred in rotating shaft, they have the limits of driving speed and precision. The rotor system has parametric variations or external disturbances such as mass unbalance variations in long operation. Therefore, it is necessary to research about magnetic bearing, which is able to support the shaft without mechanical contact and to control rotor vibration without being affected by external disturbances or parametric changes. Magnetic bearing system in the paper is composed of position sensor, digital controller, actuating amplifier and electromagnet. This paper applied the robust control method using quantitative feedback theory (QFT) to control the magnetic bearing. It also proposed design skill of optimal controller, in case the system has structured uncertainty, unstructured uncertainty and disturbance. Reduction of vibration is verified at critical rotating speed even external disturbance exists. Unbalance response, a serious problem in rotating machinery, is improved by magnetic bearing using QFT algorithm.

  • PDF

Correction of resonance frequency for RF amplifiers based on superconducting quantum interference device

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Lee, S.K.;Chong, Y.;Oh, S.J.;Semertzidis, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.4
    • /
    • pp.6-10
    • /
    • 2018
  • Low-noise amplifiers in the radio-frequency (RF) band based on the direct current (DC) superconducting quantum interference device (SQUID) can be used for quantum-limited measurements in precision physics experiments. For the prediction of peak-gain frequency of these amplifiers, we need a reliable design formula for the resonance frequency of the microstrip circuit. We improved the formula for the resonance frequency, determined by parameters of the DC SQUID and the input coil, and compared the design values with experimental values. The proposed formula showed much accurate results than the conventional formula. Minor deviation of the experimental results from the theory can be corrected by using the measured geometrical parameters of the input coil line.

Gain characteristics of SQUID-based RF amplifiers depending on device parameters

  • Lee, Y.H.;Yu, K.K.;Kim, J.M.;Lee, S.K.;Chong, Y.;Oh, S.J.;Semertzidis, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.21 no.1
    • /
    • pp.10-14
    • /
    • 2019
  • Radio-frequency (RF) amplifiers based on direct current (DC) superconducting quantum interference device (SQUID) have low-noise performance for precision physics experiments. Gain curves of SQUID RF amplifiers depend on several parameters of the SQUID and operation conditions. We are developing SQUID RF amplifiers for application to measure very weak RF signals from ultra-low-temperature high-magnetic-field microwave cavity in axion search experiments. In this study, we designed, fabricated and characterized SQUID RF amplifiers with different SQUID parameters, such as number of input coil turn, shunt resistance value of the junction and coupling capacitance in the input coil, and compared the results.

Design and Implementation for Motion Control System with Precise Driving Mechanism (정밀구동메커니즘 적용 모션제어시스템 설계 및 구현)

  • Lee, Sang-Kyung;Lee, Jun-Yeong;Choi, Yun-Seok;Park, Hong Bea
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.8 no.3
    • /
    • pp.129-136
    • /
    • 2013
  • In this paper, a motion control system based on 2-axis gimbal system is designed and implemented to drive a high speed and precision. The proposed system consists of the RS-422 interface, 2-axis gimbal platform, servo control unit integrated with a high speed DSP chip-set, servo amplifier unit, potentiometer sensor unit, and resolver sensor unit. The servo control unit using the high speed DSP firmware is designed to get a fast response without an overshoot with step input and a RMS error of low probability with ramp input. The servo amplifier unit using a voltage control is designed to resolve the zero-crossing distortion for precise motion. To verify the performance and stability of the implemented system, experiments are performed through a measurement of the time and frequency domain response in a laboratory environment by using a PXI(PCI eXtentions for Instrumentation).

Electromechanical Modeling and Experimental Verification of Differential Vibrating Accelerometer (차분 진동형 가속도계 전기적 모델링 및 실험적 검증)

  • Lee, Jung-Shin;Rhim, Jae-Wook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.6
    • /
    • pp.517-525
    • /
    • 2011
  • Differential Vibrating Accelerometer(DVA) is a small and accurate resonant device to sense the change in natural frequency in presence of acceleration input. Both mathematical modeling for the electromechanical dynamics and experimental investigation on the structural characteristics are necessary for effective designs of precision controller and high Q-factor structure. In this paper, electromechanical modeling of the resonator of DVA, electrode module, and pre-amplifier is presented. The presented method is experimentally verified by measuring the resonance frequency, effective mass, effective stiffness and Q-factor. The direct comparison of the calculated displacement and the actual pre-amplifier of DVA also indicates the effectiveness of this study.

A Study on the Magnetically Suspended Spindle with 16-pole Radial Magnets (16 극의 반경방향 전자석을 갖는 자기부상 주축계 연구)

  • Park, Jong-Kweon;Ro, Seung-Kook;Kyung, Jin-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.2
    • /
    • pp.203-212
    • /
    • 2002
  • Active magnetic hearings allow much high surface speed than conventional ball bearings and therefore greatly suitable for high speed cutting. This paper describes a design and test of an active magnetic bearing system with 16-pole radial magnets. The spindle is originally designed for a CNC lathe and driven by outer motor with 5.5 kW power and maximum speed 10,000 rpm. Considering static load condition and geometric restrictions, radial magnet is designed 16-pole type for smaller outer diameter of the spindle system. Dynamic system characteristics such as natural frequency, critical speed, stiffness, damping and system stabilities are simulated with a rigid rotor model including direct feedback controller. The designed spindle system is realized with digital PIDD controller to compensate phase lag of PWM amplifier and magnet coils. With levitation and step response experiment the control system characteristics are tested, and the spindle is rotated up to 10,000 rpm stab1y.

Implementation of an Automatic Sunrise Household Lighting System Using a PIC Microcontroller (PIC 마이크로컨트롤러를 이용한 가정용 자동해돋이 조명시스템 구현)

  • Kang Brian B.;Kang Chul-Goo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.12 s.177
    • /
    • pp.70-76
    • /
    • 2005
  • It is known that natural awakening of us in the morning is due to stimulation of the reticular activation system through biological clock in the suprachiasmatic nucleus of hypothalamus by the morning sunlight. If we sleep at dark rooms without windows and so without morning sunlight, thus, it is not easy fur us to get up refreshingly in the morning. In this paper, we propose an automatic sunrise household lighting system that helps us fer getting up cheerfully in the morning even if we sleep in dark rooms without morning sunlight. The proposed lighting system is an embedded system that turns automatically on the electric lamp and makes it brighter and brighter coincidently with the actual sunrise. The proposed system is composed of a PIC microcontroller with flash memory, a real-time clock IC, a D/A converter, an amplifier, a dimmer unit, a light bulb, a display panel and a keyboard. The validity of the proposed intelligent lighting system is demonstrated via a prototype production and experimentation.

A Study on Acoustic Emission Characteristics through the Cyclic Thermal Test of Thermal Barrier Coating by Plasma Spray Process (플라즈마 용사법에 의한 열차폐 코팅의 열피로에 따른 AE신호 특성 연구)

  • Park J.H.;Lee K.H.;Ye K.H.;Kim S.T.;Jeon C.H.;Kim J.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1349-1352
    • /
    • 2005
  • This paper is to investigate a defect for thermal barrier coating layers by acoustic emission method in 4-point bending test. The two-layer thermal barrier coating is composed of $150\mu{m}\;CoNiCrAlY\;bond\;coating\;by\;vacuum\;plasma\;spray(VPS)\;process\;and\;250\mu{m}\;ZrO_2-8wt%Y_2O_3$ ceramic coating layer by air plasma spray(APS) process on Inconel-718. The specimen prepared by cyclic thermal test(500, 1000, 2000cycle) at $1050^{\circ}C$ The AE monitoring system is composed of PICO type sensor, a wide band pre-amplifier(40dB), PC and AE DSP(16/32 PAC) board. The AE event, amplitude, Cumulative energy and count of coating specimens is evaluated according to cyclic thermal test.

  • PDF