• Title/Summary/Keyword: Precision Time Protocol

Search Result 62, Processing Time 0.089 seconds

Time of Arrival range Based Wireless Sensor Localization in Precision Agriculture

  • Lee, Sang-Hyun;Moon, Kyung-Il
    • International journal of advanced smart convergence
    • /
    • v.3 no.2
    • /
    • pp.14-17
    • /
    • 2014
  • Precision agriculture relies on information technology, whose precondition is providing real-time and accurate information. It depends on various kinds of advanced sensors, such as environmental temperature and humidity, wind speed, light intensity, and other types of sensors. Currently, it is a hot topic how to collect accurate information, the main raw data for agricultural experts, monitored by these sensors timely. Most existing work in WSNs addresses their fundamental challenges, including power supply, limited memory, processing power and communication bandwidth and focuses entirely on their operating system and networking protocol design and implementation. However, it is not easy to find the self-localization capability of wireless sensor networks. Because of constraints on the cost and size of sensors, energy consumption, implementation environment and the deployment of sensors, most sensors do not know their locations. This paper provides maximum likelihood estimators for sensor location estimation when observations are time-of arrival (TOA) range measurement.

The Effect on Improvement of Muscle Strength Imbalance According to Load Deviation Protocol of Whole Body Vibration Exercise (부하 편차 방식의 전신진동운동이 하지 근력 불균형 개선에 미치는 효과)

  • Seo, Shin Bae;Kang, Seung Rok;Yu, Chang Ho;Min, Jin Young;Kwon, Tae Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.10
    • /
    • pp.1095-1101
    • /
    • 2013
  • The purpose of this study was to verify the effect on improvement of muscle strength unbalance according to load deviation protocol during whole body vibration exercise. Seventeen female volunteers (age $22{\pm}3$ years, height $160{\pm}4.9$ cm, weight $49{\pm}.8$ kg) participated in this experiment. The subjects performed squat exercise in WBV platform. Exercise were performed five set a day including 15 time a set, three days a week, and during 4 weeks. Vibration stimulus was 25Hz as frequency and intensity was dominant leg 1mm and non-dominant leg 4mm. The results in WBV group showed that the differences of peak torque in 16% were getting decreasing significantly after 4 weeks from 16.2% to 5.2%. This result means that WBV with load deviation protocol could provide muscle strength exercise for muscle strength balance. Our study found out that WBV of load deviation protocol could provide muscle strength exercise for improving muscle imbalance.

Design and Implementation of PTP Gateway to Extend IEEE 1588 to Zigbee networks (IEEE 1588의 Zigbee 네트워크 확장을 위한 PTP 게이트웨이 설계 및 구현)

  • Cho, Hyun-Tae;Jung, Yeon-Su;Lee, Seung-Woo;Jin, Young-Woo;Baek, Yun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.34 no.12A
    • /
    • pp.971-981
    • /
    • 2009
  • The coordination of distributed entities and events requires time synchronization. Precision time synchronization enables a variety of extensions of applications and provides much accurate information. The IEEE 1588 precision time protocol (PTP) provides a standard method to synchronize devices in a network. This paper deals with the design and implementation of a PTP gateway to extend IEEE 1588 to Zigbee networks. The PTP gateway can not only extend IEEE 1588 to Zigbee networks but also share the same time reference using IEEE 1588 between two or more Zigbee networks. This paper also presents experiments and performance evaluation of time synchronization using the PTP gateway. Our result established a method for nodes in a network to maintain their clocks to within a 300 nanosecond offset from the reference clock of a master node via Ethernet.

Design and Implementation of Precision Time Synchronization in Wireless Networks Using ZigBee (ZigBee를 이용한 무선 네트워크 환경에서의 정밀 시각 동기 기법 설계 및 구현)

  • Cho, Hyun-Tae;Son, Sang-Hyun;Baek, Yun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.5A
    • /
    • pp.561-570
    • /
    • 2008
  • Time synchronization is essential for a number of network applications such as high speed communication and parallel/distribution processing systems. As the era of ubiquitous computing is ushered in, the high precise time synchronization in wireless networks have been required in. This paper presents the design ana the implementation of the high precision time synchronization in wireless networks using ZigBee. To achieve high precision requirements, we have tried to analyze and reduce error factors such as the latency and jitters of a protocol stack on wireless environments. In addition, this paper includes some experiments and performance evaluations of our system. The result is that we established for nodes in a network to maintain their elects to within a 50 nanosecond offset from the reference clock.

Internet-based Real-Time Remote Monitoring System for High-Speed Machining Process (인터넷 기반 실시간 원격 고속가공 모니터링)

  • 이우영;최성주;김흥배
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.05a
    • /
    • pp.952-955
    • /
    • 2000
  • Nowadays, Internet is so popular that we can easily access the remote site to search information and to communicate remote site and users. People who want to make a collaborate working environment can use JAVA, CORBA, and other internet programming tools like a Perl/XML. The mechanist are try to make the environment fur collaboration within design/manufacturing, simulation, remote sensing through TCP/IP And many industries and research institutions are working towards the agile manufacturing. This paper describes an internet-based real-Time remote monitoring system. The system consists of a hardware setup and a software interface. The hardware setup consists of a machine and its data acquisition hardware, while the software interface incorporates the data acquisition software, the server program, and the client program. The server program acts as the main interface between the data acquisition system and the internet technology. The client program is to be distributed to the remote users who want to monitor the machining status. The system has been demonstrated and verified for an industrial High-Speed Machine (HSM) especially measuring cutting force and acoustic emission. To share the signal, we make the WWW server and display its value. The system has been found to be highly efficient, reliable and accurate.

  • PDF

Does the palatal vault form have an influence on the scan time and accuracy of intraoral scans of completely edentulous arches? An in-vitro study

  • Osman, Reham;Alharbi, Nawal
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.5
    • /
    • pp.294-304
    • /
    • 2022
  • PURPOSE. The purpose of this study was to evaluate the influence of different palatal vault configurations on the accuracy and scan speed of intraoral scans (IO) of completely edentulous arches. MATERIALS AND METHODS. Three different virtual models of a completely edentulous maxillary arch with different palatal vault heights- Cl I moderate (U-shaped), Cl II deep (steep) and Cl III shallow (flat)-were digitally designed using CAD software (Meshmixer; Autodesk, USA) and 3D-printed using SLA-based 3D-printer (XFAB; DWS, Italy) (n = 30; 10 specimens per group). Each model was scanned using intraoral scanner (Trios 3; 3ShapeTM, Denmark). Scanning time was recorded for all samples. Scanning accuracy (trueness and precision) were evaluated using digital subtraction technique using Geomagic Control X v2020 (Geomagic; 3DSystems, USA). One-way analysis of variance (ANOVA) test was used to detect differences in scanning time, trueness and precision among the test groups. Statistical significance was set at α = .05. RESULTS. The scan process could not be completed for Class II group and manufacturer's recommended technique had to be modified. ANOVA revealed no statistically significant difference in trueness and precision values among the test groups (P=.959 and P=.658, respectively). Deep palatal vault (Cl II) showed significantly longer scan time compared to Cl I and III. CONCLUSION. The selection of scan protocol in complex cases such as deep palatal vault is of utmost importance. The modified, adopted longer path scan protocol of deep vault cases resulted in increased scan time when compared to the other two groups.

Method of Real-time Communication in Android OS (안드로이드 운영체제 상에서 실시간 통신 방법)

  • Woo, Sang-Ho;Lee, Sang-Gil;Lee, Cheol-Hoon
    • The Journal of the Korea Contents Association
    • /
    • v.21 no.1
    • /
    • pp.475-484
    • /
    • 2021
  • The Android OS has quickly established itself with the smartphone market and is being applied in a variety of ways such as navigation and refrigerator panels. Existing terminals can implement services that require high precision while using RTOS that requires accurate execution time, but Android OS has a disadvantage in that it cannot provide high-precision real-time performance. In this paper, we propose a real-time communication method that operates in the Android OS. Real-time communication reduces the load using the UDP protocol, and configures the real-time operating system time tick through a high-precision timer in the kernel area. An Android application level library was created to implement real-time communication and compared with the existing Android library for real-time performance verification.

Data Acquisition System of Compound Semiconductor Fabrication (화합물반도체공장의 생산정보수집시스템)

  • Lee S.W.;Song J.Y.;Lee H.K.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.335-336
    • /
    • 2006
  • Compound semiconductor manufacturing environment also has been emerged as mass customization and open foundry service so integrated manufacturing system is needed. In this study, we design data acquisition system of compound semiconductor fabrication that has monitoring and control of process. The developed DAS is consisted of key-in system inputted by operator and automatic acquisition system by GEM protocol. And we implemented them in the actual compound semiconductor. It is expected that using developed system would offer precise process information to buyer, reduce a lead-time, and obey a due-dates and so on.

  • PDF

A Study on the Implementation of Fieldbus-Based Manufacturing Automation Systems (필드버스를 이용한 생산자동화 시스템 구축 기술 연구)

  • Hong, Seung-Ho;Park, Tae-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.91-102
    • /
    • 1999
  • Fieldbus provides real-time data communication among field devices in the manufacturing automation and process control systems. In this study, an experimental model of fieldbus-based manufacturing automation system is developed. Experimental model consists of two robots, two conveyor belts, NC machine, PLC, sensors and operator station. These machines are interconnected into the Profibus network, and exchange their data through the services provided by FMS(Fieldbus Message Specification), which is the application layer protocol of Profibus. The experimental model is used to measure the network-induced delay of variable and file data transmitted through FMS services. Network-induced delays are collected and analyzed on each sublayer of Profibus protocol stack. The results obtained from the experiment of this study can be effectively utilized when fieldbus is implemented on the practical manufacturing automation systems.

  • PDF

Precision Improvement Technique of Propagation Delay Distance Measurement Using IEEE 1588 PTP (IEEE 1588 PTP를 이용한 전파 지연 거리 측정의 정밀도 향상 기법)

  • Gu, Young Mo;Boo, Jung-il;Ha, Jeong-wan;Kim, Bokki
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.6
    • /
    • pp.515-519
    • /
    • 2021
  • IEEE 1588 PTP is a precision time protocol in which two systems synchronize without the aid of GPS by exchanging packets including transmission/reception time information. In the time synchronization process, the propagation delay time can be calculated and the distance between the two systems can be measured using this. In this paper, we proposed a method to improve the distance measurement precision less than the modulation symbol period using the timing error information extracted from the preamble of the received packet. Computer simulations show that the distance measurement precision is proportional to the length of the preamble PN sequence and the signal-to-noise ratio.