• Title/Summary/Keyword: Precast concrete slab

Search Result 160, Processing Time 0.025 seconds

Shear Capacity of Precast Concrete Triple Ribs Slab (프리캐스트 콘크리트 트리플 리브 슬래브의 전단성능)

  • Hwang, Seung-Bum;Seo, Soo-Yeon;Lee, Kang-Cheol;Lee, Seok-Hyun
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.4
    • /
    • pp.489-496
    • /
    • 2016
  • Recently, a concern about hollow core precast concrete (PC) slab has been increased as a method to improve the construction ability by reducing the self weight of structures during the construction. Hollow core slab which is known as a typical PC slab in domestic construction of PC building has a problem to put shear reinforcements in the web of element during the production of element in the factory. With regard to this point, recently, tripple ribs slab (TRS) which can be said as a new type of half PC slab system was developed. In TRS, it is possible to place shear reinforcements in PC element during the production of the element in the factory. This paper presents the shear test result of TRS which was done by one point loading test under simple support condition. Test parameters are the presence of cast-in-place (CIP) concrete and the contribution of lattice bars. From the test, it was found that the TRS has sufficient shear capacity to resist the design load and its strength can be predicted by the code equations for general beam. It is recommended to ignore the strength of lattice bar in the calculation of shear strength during the construction since its contribution is too low to be considered when CIP is not casted.

Experimental Study on Shear Connector for Precast Concrete Decks

  • Chung, Chul-Hun;Shim, Chang-Su;Jeong, Un-Yong
    • KCI Concrete Journal
    • /
    • v.13 no.1
    • /
    • pp.61-67
    • /
    • 2001
  • For the design of shear connection for the composite precast concrete slabs. it is necessary to investigate its strength, stiffness, slip capacity and fatigue endurance. For theme purposes, push-out tests were performed with variations of the stud shank diameter and the compressive strength of the mortar. From the experimental studies, it could be observed that the deformation of the shear studs in a full-depth precast concrete slabs were greater than those in a cast-in-place slabs. The static strength of the shear connections obtained agree approximately with those evaluated from the tensile strength of the stud shear connectors owing to the effect of the bedding layer between the slabs and the beams. An empirical equation for the initial shear stiffness of a shear connection was also proposed. On the basis of the push-out tests, a full-scale composite beams with 8.0m span was designed and fatigue tests were carried out to study the behaviour of the stud shear connection and its effects on the flexural behaviour of the beam. The bonding arid friction between the concrete slab and the steel beam considerably increased the fatigue endurance of the shear connection.

  • PDF

Modelling and integrity assessment of shear connectors in precast cast-in-situ concrete bridges

  • Moyo, Pilate;Sibanda, Bongani;Beushausen, Hans
    • Structural Engineering and Mechanics
    • /
    • v.42 no.1
    • /
    • pp.55-72
    • /
    • 2012
  • Precast-cast insitu concrete bridge construction is widely practiced for small to medium span structures. These bridges consist of precast pre-stressed concrete beams of various cross-sections with a cast in-situ reinforced concrete slab. The connection between the beams and the slab is via shear links often included during the manufacturing process of the beams. This form of construction is attractive as it provides for standardisation, reduced formwork and construction time. The assessment of the integrity of shear connectors in existing bridges is a major challenge. A procedure for assessment of shear connectors based on vibration testing and finite element model updating is proposed. The technique is applied successfully to a scaled model bridge model and an existing bridge structure.

Fabrication of Concrete Slabs for Precast Pavement Construction (조립식 포장 시공을 위한 콘크리트 슬래브 제작)

  • Park, Hee-Beom;Kim, Seong-Min;Park, Won-Joo;Lee, Seung-Jae
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2010.05a
    • /
    • pp.447-448
    • /
    • 2010
  • This study was conducted to investigate the feasibility of precast concrete slab fabrication. Slabs were designed including detailed element techniques, and based on the design, high performance precast slabs could be fabricated.

  • PDF

The Flexural Behavior including Ductility of Half Precast Concrete Slab with Welded Deformed Wire Fabric (용접철망을 사용한 반두께 P.C.슬래브의 휨 및 연성거동)

  • 이광수;최종수;조민형;신성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.4
    • /
    • pp.153-160
    • /
    • 1994
  • Ten Half precast concrete slabs reinforced with welded deformed wire fabric were tested under two concentrated loads to investigate the flexural moment and ductile capacity. The test variables were the compressive strength of topping concrete, quantitative roughness, and reinforcernent ratio. The effects of each test variables were studied separately. Test results were as followings. The ultimate strength design method is applicable to predict flexural strength for Half P.C. concrete slab with welded deformed wire fabric and quantitative roughness. It is proper to consider 0.0035 strain ;is yielding stress of the welded deformed wire fabric. The ductility index of Half precast concrete slab with welded deformed wire fabric showed lower value. Therefore to enhance the ductility capacity the normal defomed bar should be used with the welded deformed wire fabric for the longitudinal reinforcement.

Effect of Different Interfacial Shear Reinforcement Lengths and Types on Flexural Behavior of PC/PS-Half Slab (계면 전단 보강근 길이 및 형태 변화에 따른 PC/PS-Half Slab의 휨 거동)

  • 이차돈;이종민
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.131-138
    • /
    • 2001
  • Total number of seven experimental specimens of size 4.6m$\times$2.4m are designed in full scale with due considerations given to the constructability as well as economic applications. Each specimen is made with different shapes of trusses or hooks along the interfacial surface between precast panel and topping concrete to maintain appropriate shear resistance. Structural performances in terms of strength and ductility under flexural load are examined for each specimen with different types of interfacial shear resistance reinforcements. Experimentally obtained flexural strength are also compared with those of analytical predictions. Based on experimental and analytical studies, design equations are suggested for the developed precast prestressed concrete half-slab systems.

  • PDF

Performance of Beam-Slab connection of Waffle Shape Precast Prestressed Concrete Slab System (와플(Waffle) 형상을 가지는 PC슬래브의 보-슬래브 접합 성능)

  • Heo, Seok-Jae;Kim, Hyun-Jin;Ryu, Han-Gook;Choi, Kyoung-Kyu;Cho, Seung-Ho;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.21-24
    • /
    • 2008
  • This research verifies efficiency of Beam-Slab connection with Precast Prestressed Concrete Slab System of WAffle Shape(WAS) which solves problems of double-T system(DTS). Specimen is produced in Precast Concrete factories and is made in a way that WAS is layed across inverted T beam(ITB) and then it is filled with packing. After casting topping concrete into the specimen, curing is carried out. Variable are width of shear key and packing. The analysis is carried out in comparison between displacement and strength of Beam-Slab connection of specimen. The variable is not a effect in joint efficiency. Consequently, it may plans at the minimum with of shear key that packing is easy, will not affect strength.

  • PDF

Interface Shear Strength in Half Precast Concrete Slab (반두께 P.C. 슬래브의 면내전단내력에 관한 연구)

  • 이광수;김대근;최종수;신성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.4
    • /
    • pp.161-168
    • /
    • 1994
  • Half-P.C. slab system is the composite structural system which utilizes precast concrete for lower portion and cast in situ concrete for upper portion slab. When the composite slab using Half P.C. slab is deformed by flexural moment, horizontal shear happened at the interface between Half P.C. slab and topping concrete. To resist horizontal shear strength a scratch method has tried. To determine ultimate interface shear strength, shear stress, and shear coefficient, high and normal strength concrete are used for topping concrete. Major variables are compressive strength of topping concrete with or without shear reinforcement, quantitative roughness of the P.C. :surface and tie or untie of the stud with welded deformed wire fabric in the P.C. member. The Icross sectional area on joints is 3,200 $cm^2$ in all specimens. Test results showed that shear stress increased, as the depth of the quantitative roughness increased. The horizontal shear strength could be resisted with safe by the quantitative roughness without shear tie. A shear coefficient determinant equation is proposed such that K = 0.025918 + 0.0068894$\cdot$R – 0.000182354${\cdot}R^2$

Analytical Studies on Shape of Shear Pocket of Full-Depth Precast Slab (프리캐스트 바닥판의 전단포켓 형상에 관한 해석 연구)

  • Han Sang-Yun;Lee Man-Sup;Lee Seong-Rok;Song Jae-Joon;Kang Young-Jong
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1119-1124
    • /
    • 2004
  • Full depth precast concrete bridge deck system can be advantageously to reduce construction time, hence lowering the cost. This system has several significant design and construction component. To connect between the concrete slab and steel girder, precast deck has shear pocket. Post-tensioning tightens the joints and prevents any leakage though the joint. When post-tensioning is applied, stress concentration occurs in the edge of shear pocket. In this study, precast decks using four types of shear pocket is analyzed by F.E.M.

  • PDF