Control And Monitoring Of Air Circuit Breaker Using Digital Protective Relay (디지털보호계전기를 이용한 기중차단기 제어 및 모니터링)

  • Lee, Sung-Hwan;Park, Sang-Bae;Ahn, Ihn-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.240-242
    • /
    • 2001
  • On this research, to catch up with international trend on the power system utilities move to be digitalized and move to network is certainly technological on the global business world, to compete with advanced foreign countries in the range of transmit and distribute power system and to take possession of first market share within country, we talked over a monitoring system to diagnose, monitor ACB(Air Circuit Breaker) only which is operated on the low level voltage Power plant. AMS(ACB Monitoring System) have be configured with several modules such as engine module which acquire engineering data from HICM360/860(Communication Control Units) and analyze and save it, database module which restore data and can be inquired, system monitoring view module which reflects fields information within a second, realtime trend window, historical trend window, reports as daily and yearly. In a near future, AMS must upgrade GUI to have easy to handle and have to have a field test to fit on real plants, so it will have faith in system reliability as it can apply power plant monitoring system in wide.

  • PDF

A Study on Analysis of Propagation Speed of Power Frequency by Generation Drop (발전기 탈락에 따른 주파수의 전파속도 해석에 관한 연구)

  • Kim, Hak-Man;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.4
    • /
    • pp.295-300
    • /
    • 2014
  • The frequency is an important operating parameter of a power system. There is an increasing importance of constant monitoring of frequency to achieve stable power supply by WAMS(wide area monitoring system) and FNET(Frequency Monitoring Network). This paper is part of development of a network-based frequency monitoring and failure prediction system for wide-area intelligent protection relaying. In this paper, analysis of propagation speed of power frequency by generation drop using the PSS/E was carried out. For dynamic analysis, the 11 metropolitan areas offices of KEPCO divided into five groups of Seoul, Gangwon, Chungcheong, Honam, and Yeongnam group, study was performed.

Low-power Environmental Monitoring System for ZigBee Wireless Sensor Network

  • Alhmiedat, Tareq
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.10
    • /
    • pp.4781-4803
    • /
    • 2017
  • Environmental monitoring systems using Wireless Sensor Networks (WSNs) face the challenge of high power consumption, due to the high levels of multi-hop data communication involved. In order to overcome the issue of fast energy depletion, a proof-of-concept implementation proves that adopting a clustering algorithm in environmental monitoring applications will significantly reduce the total power consumption for environment sensor nodes. In this paper, an energy-efficient WSN-based environmental monitoring system is proposed and implemented, using eight sensor nodes deployed over an area of $1km^2$, which took place in the city of Tabuk in Saudi Arabia. The effectiveness of the proposed environmental monitoring system has been demonstrated through adopting a number of real experimental studies.

A Study on the Power System Control and Monitoring Technique Using CAN (CAN을 이용한 발전계통의 제어 및 모니터링 기법 연구)

  • Jung, Joon-Hong;Choi, Soo-Young;Park, Ki-Heon
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.5
    • /
    • pp.268-276
    • /
    • 2003
  • In this paper, we present a new control and monitoring technique for a power system using CAN(Controller Area Network). Feedback control systems having co'ntrol loops closed through a network(i.e. Ethernet, ControlNet, CAN) are called NCSs(Networked Control Systems). The major problem of NCSs is the variation of stability property according to time delay including network-induced delay and computation delay in nodes. We present a new stability analysis method of NCSs with time delay exploiting a state-space model of LTI(Linear Time Invariant) interconnected systems. The proposed method can determine a proper sampling period of NCSs that preserves stability performance even in NCSs with a dynamic controller. We design CAN nodes which can transmit control and monitoring data through CAN bus and apply these to NCSs for a power system. The results of the experiment validate effectiveness of our control and monitoring technique for a power system.

Power Quality Measurement Using TMS320C6701 Processor (TMS320C6701 프로세서를 이용한 전력 품질 측정)

  • Shin, Myong-Jun;Son, Young-Ik;Kim, Kab-Il
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.50-52
    • /
    • 2005
  • Research interests in PQ(Power Quality) measurement and monitoring system have been increased. This paper describes an experimental result for monitoring system that monitors power quality and undesirable accidents when distributed generations are connected to the power grid. Prior to develop a physical monitoring system for distributed generation applications, we constitute a mesuring system for the general PQ factors. In this paper, an approach to how to measure the PQ elements is presented by using TMS320C6701 processor. Simulation results using the PSCAD and the power system simulation equipment Dobel have verified the proposed measurement system.

  • PDF

Performance monitoring results of large-scale PV system (중대규모 계통연계형 PV시스템의 성능결과)

  • So, Jung-Hun;Yu, Gwon-Jong;Jung, Young-Seok;Yu, Byung-Gyu;Hwan, Hye-Mi;Choi, Ju-Yeop
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1165-1166
    • /
    • 2006
  • This paper presents performance monitoring results of large scale photovoltaic (PV) system supported by general dissemination & regional energy program in korea government polices for new and renewable energy resources. 80kW PV system and monitoring system is constructed and monitored PV system performance to observe the overall effect of environmental conditions on their operation characteristics. The PV system performance has been evaluated and analyzed for component perspective (PV array and power conditioning unit) and global perspective (system efficiency, capacity factor, and electrical power energy and power quality etc.) for six month monitoring periods.

  • PDF

A Study on the Signal Analysis of Loose Parts Monitoring System (LPMS 신호분석 연구)

  • Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.839-841
    • /
    • 2014
  • The Nuclear Steam Supply System(NSSS) is designed to provide an integrated approach that includes areas of monitoring relevant to the integrity of the NSSS. LPMS is designed to function as an alarm system by providing sensor channel alarms for the associated subsystems. LPMS is equipped to provide analysis tools for new alarm events, historical events and for historical periodically stored channel data (e.g. waveforms) for most channels. This paper is intended to introduce the diagnosis principle and abnormal symptom of loose parts monitoring system as a monitoring tool in Nuclear Steam Supply System. And also, we are going to introduce signal analysis program in order to perform the actual diagnosis in power plants.

  • PDF

A Technical Trend on On-Line Condition Monitoring and Diagnostics of Power Equipments (배전설비의 온라인 모니터링과 진단 기술 동향)

  • Lim, Wan-Soo;Lee, Tae-Woo;Yeo, Woon-Cheol;Lee, Sung-Gil;Choi, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1974-1975
    • /
    • 2007
  • Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on-line condition monitoring of energized equipment is applicable both as standalone system and with an interface with power quality monitoring system. The paper presents the results of wireless temperature monitoring of switchgear at a power plant over a two-year period.

  • PDF

Site Monitoring System of Earthquake, Fault and Slope for Nuclear Power Plant Sites (원자력발전소의 부지감시시스템의 운영과 활용)

  • Park, Donghee;Cho, Sung-il;Lee, Yong Hee;Choi, Weon Hack;Lee, Dong Hun;Kim, Hak-sung
    • Economic and Environmental Geology
    • /
    • v.51 no.2
    • /
    • pp.185-201
    • /
    • 2018
  • Nuclear power plants(NPP) are constructed and operated to ensure safety against natural disasters and man-made disasters in all processes including site selection, site survey, design, construction, and operation. This paper will introduce a series of efforts conducted in Korea Hydro and Nuclear Power Co. Ltd., to assure the safety of nuclear power plant against earthquakes and other natural hazards. In particular, the present status of the earthquake, fault, and slope safety monitoring system for nuclear power plants is introduced. A earthquake observatory network for the NPP sites has been built up for nuclear safety and providing adequate seismic design standards for NPP sites by monitoring seismicity in and around NPPs since 1999. The Eupcheon Fault Monitoring System, composed of a strainmeter, seismometer, creepmeter, Global Positioning System, and groundwater meter, was installed to assess the safety of the Wolsung Nuclear Power Plant against earthquakes by monitoring the short- and long-term behavioral characteristics of the Eupcheon fault. Through the analysis of measured data, it was verified that the Eupcheon fault is a relatively stable fault that is not affected by earthquakes occurring around the southeastern part of the Korean peninsula. In addition, it was confirmed that the fault monitoring system could be very useful for seismic safety analysis and earthquake prediction study on the fault. K-SLOPE System for systematic slope monitoring was successfully developed for monitoring of the slope at nuclear power plants. Several kinds of monitoring devices including an inclinometer, tiltmeter, tension-wire, and precipitation gauge were installed on the NPP slope. A macro deformation analysis using terrestrial LiDAR (Light Detection And Ranging) was performed for overall slope deformation evaluation.

Acoustic Valve Leak Diagnosis and Monitoring System for Power Plant Valves (발전용 밸브누설 음향 진단 및 감시시스템)

  • Lee, Sang-Guk
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.425-430
    • /
    • 2008
  • To verify the system performance of portable AE leak diagnosis system which can measure with moving conditions, AE activities such as RMS voltage level, AE signal trend, leak rate degree according to AE database, FFT spectrum were measured during operation on total 11 valves of the secondary system in nuclear power plant. AE activities were recorded and analyzed from various operating conditions including different temperature, type of valve, pressure difference, valve size and fluid. The results of this field study are utilized to select the type of sensors, the frequency band for filtering and thereby to improve the signal-to-noise ratio for diagnosis for diagnosis or monitoring of valves in operation. As the final result of application study above, portable type leak diagnosis system by AE was developed. The outcome of the study can be definitely applied as a means of the diagnosis or monitoring system for energy saving and prevention of accident for power plant valve. The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18 ". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.