• 제목/요약/키워드: Power supply noise

검색결과 483건 처리시간 0.026초

Electromagnetic Model to Estimate the Vibrations of a Switched Reluctance Machine on the Basis of the Eelctric Power Supply

  • Badreddine, Benabdallah Mohammed
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권1호
    • /
    • pp.60-67
    • /
    • 2008
  • The vibrations and noise origin in electric material is due to several coupled physical phenomena. The revolving electric machine complete modeling is complex; it does not allow simple parametric machine structure studies for various operation modes. This work presents a simple electromagnetic model which makes possible the machine principal parts flow estimation from flux density. Special interest is given in determining Switched Reluctance Machine (S.R.M) radial acceleration in accordance with the current supply. Our focus will be only on the magnetic origin efforts that are dominating in the S.R.M. The efforts calculation versus the current is presented in the case of a machine with a linearized rate. These efforts are considered as a tangential force producing the torque and a radial force that generates no torque. The application is realized on a 6/4 low power S.R.M type (6 stator teeth and 4 teeth rotor). The mechanical response is substituted in a transfer function. The model takes account of the power supply of the machine, the relation between the current supply and the efforts as well as the vibratory response of the machine to these efforts. Finally, the model is validated by comparison with similar experimental results within the framework of the definite assumptions.

구조분할 해석기법 기반 전원보드 공통모드 노이즈 감쇠 설계 (Common-Mode Noise Suppression in Switched-Mode Power Supply Boards Using Segmentation Method)

  • 김명회;노동규;정성석;곽규민
    • 한국전자파학회논문지
    • /
    • 제29권2호
    • /
    • pp.142-145
    • /
    • 2018
  • 본 논문에서는 전원보드의 공통모드 노이즈 감쇠를 위한 디커플링 커패시터 회로를 효율적으로 시뮬레이션할 수 있는 구조분할 해석기법을 제시한다. 제시하는 구조분할 해석기법이 적용된 전원보드 설계에서는 보드를 두 부분으로 구조분할하였으며, 분할된 구조와 커패시터 회로의 임피던스 파라미터를 재결합하기 위한 방법을 제시하였다. 구조분할 해석기법을 적용함으로써 공통모드 노이즈 감쇠 시뮬레이션에 수행되는 시간을 46 % 이상 단축하였다.

A Low Noise and Low Power RF Front-End for 5.8-GHz DSRC Receiver in 0.13 ㎛ CMOS

  • Choi, Jae-Yi;Seo, Shin-Hyouk;Moon, Hyun-Won;Nam, Il-Ku
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제11권1호
    • /
    • pp.59-64
    • /
    • 2011
  • A low noise and low power RF front-end for 5.8 GHz DSRC (Dedicated Short Range Communication) receiver is presented. The RF front-end is composed of a single-to-differential two-stage LNA and a Gilbert down-conversion mixer. In order to remove an external balun and 5.8 GHz LC load tuning circuit, a single-to-differential LNA with capacitive cross coupled pair is proposed. The RF front-end is fabricated in a 0.13 ${\mu}m$ CMOS process and draws 7.3 mA from a 1.2 V supply voltage. It shows a voltage gain of 40 dB and a noise figure (NF) lower than 4.5 dB over the entire DSRC band.

발전소 복수 공급 배관계의 고진동과 분기 배기배관의 절손 규명 (Examination on High Vibration and Branch Vent Pipe's Failure of Complex Piping System Suppling Condensate-Water in Power Site)

  • 김연환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.380-384
    • /
    • 2010
  • A disturbance flow at piping bands and discontinuous regions such as a valve, a header has a intense broadband internal pressure field and a sound field which are propagated through the piping system The fields becomes the source of a vibration of this piping system. Intense broadband disturbance flow at a discontinuous region such as elbows, valves or headers generates an acoustical pulsation. The pulsation becomes the source of structural vibration at the piping system. If it coincides with the natural frequency of the pipe system, excessive vibration results. High-level vibration due to the pressure pulsation affects the reliability of the plant piping system. This paper discusses the high vibration and the branch vent pipe's failure of condensate-water supply piping system due to the effect of acoustical pulsations by flow turbulence from the flow control valves of globe type in a power site.

  • PDF

Implementation of Multi-adaptive Filter for EOG Removal and Biofeedback Output Controller

  • Ahn, Bo-Sep;Kim, Pil-Un;Cho, Jin-Ho;Kim, Myoung-Nam
    • 한국멀티미디어학회논문지
    • /
    • 제7권12호
    • /
    • pp.1650-1656
    • /
    • 2004
  • In this paper, a multi-adaptive filter is proposed for removing EOG and the 60 Hz power supply noise from EEG measured in the frontal lobe and the feedback output control method is implemented for biofeedback. The multi-adaptive filter has been implemented on the TMS320C6711 DSP system and the feedback output control algorithm has been realized by calculating the ratio of alpha wave on the TMS320C31 DSP system with real time performance. Through the experiment using the implemented multi-adaptive filter and feedback output controller, we demonstrate that the proposed adaptive filter effectively removes EOG and the 60 Hz power supply noise from the measured EEG in the frontal lobe and the feedback algorithm controls the level of stimulation by the ratio of the alpha wave.

  • PDF

비디오 시스템을 위한 저전압, 디지털 자동이득 조절기 (A Low Voltage, Digital Automatic Gain Controller)

  • 권진호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.183-186
    • /
    • 2000
  • In this paper we propose a new architecture of a programmable digital automatic gain controller(AGC) for analog interface in mixed mode systems. Compared with conventional analog AGCs which have difficulties in integration due to large capacitors, the proposed AGC is easily integrated. So the production cost can be reduced. In addition, The proposed AGC has a better performance in temperature, and power supply variations, and substrate noise than analog counterparts do. To prevent erroneous operations of the AGC due to noise, a mal-function preventer is newly proposed. In addition, to achieve an optimized AGC time constant, we propose a logic block which controls an up-down counting clock. This is directly related to the changing speed of the AGC gain. Implemented with a 0.25 $\mu\textrm{m}$ 1-poly, 5-metal CMOS parameters, the AGC operates from a single 2.5V power supply with the dynamic range of 36.ldB and occupies active area of 500$\mu\textrm{m}$${\times}$600$\mu\textrm{m}$

  • PDF

LPMS 신호분석 연구 (A Study on the Signal Analysis of Loose Parts Monitoring System)

  • 이상국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.839-841
    • /
    • 2014
  • The Nuclear Steam Supply System(NSSS) is designed to provide an integrated approach that includes areas of monitoring relevant to the integrity of the NSSS. LPMS is designed to function as an alarm system by providing sensor channel alarms for the associated subsystems. LPMS is equipped to provide analysis tools for new alarm events, historical events and for historical periodically stored channel data (e.g. waveforms) for most channels. This paper is intended to introduce the diagnosis principle and abnormal symptom of loose parts monitoring system as a monitoring tool in Nuclear Steam Supply System. And also, we are going to introduce signal analysis program in order to perform the actual diagnosis in power plants.

  • PDF

수도사업장 고조파 측정, 분석을 통한 관리기준 만족여부 조사 (To examine of management standard by the harmonics measured and analyzed in water supply field)

  • 홍성택;이은춘;신강욱;임재일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.296-298
    • /
    • 2003
  • At the water supply field, high voltage induction motor is main facility of a load equipment. The motor is often out of order and its noise, generated heat, loss etc occured occasionally. especially, transmission motor for flux control generates an amount of the harmonics then have a bad influence upon the electric power system. In this study, to analyze the total harmonics distortion of the water supply field receiving high voltage, the harmonics measured and analyzed using the PQA(Power Quality Analyzer) according to the electric power system and electrical load and the reduction method presented.

  • PDF

센서 네트워크를 위한 2.4 GHz 저잡음 커플드 링 발진기 (A 2.4 GHz Low-Noise Coupled Ring Oscillator with Quadrature Output for Sensor Networks)

  • 심재훈
    • 센서학회지
    • /
    • 제28권2호
    • /
    • pp.121-126
    • /
    • 2019
  • The voltage-controlled oscillator is one of the fundamental building blocks that determine the signal quality and power consumption in RF transceivers for wireless sensor networks. Ring oscillators are attractive owing to their small form factor and multi-phase capability despite the relatively poor phase noise performance in comparison with LC oscillators. The phase noise of a ring oscillator can be improved by using a coupled structure that works at a lower frequency. This paper introduces a 2.4 GHz low-noise ring oscillator that consists of two 3-stage coupled ring oscillators. Each sub-oscillator operates at 800 MHz, and the multi-phase signals are combined to generate a 2.4 GHz quadrature output. The voltage-controlled ring oscillator designed in a 65-nm standard CMOS technology has a tuning range of 800 MHz and exhibits the phase noise of -104 dBc/Hz at 1 MHz offset. The power consumption is 13.3 mW from a 1.2 V supply voltage.

APR 1400급 원자로냉각재펌프의 회전체 진동평가에 관한 고찰 (Introduction of Vibration Evaluation for APR 1400 Reactor Coolant Pump Shaft)

  • 김익중;임도현;김민철;방상윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.110-115
    • /
    • 2014
  • The nuclear power plant was launched by Kori unit 1 in 1978 years. Currently, 23 nuclear power plants have been operating in Korea since 1978 years. The localization was completed for most of the reactor facility from Hanbit(Youngkwang) unit 3&4. However, RCP(Reactor Coolant Pump) and MMIS(Man Machine Interface System) is an important technology that has been excluded from the scope of the technical transfer has been dependent on a specific overseas vendor. Recent success in RCP development through co-operation with government and industries. Developed RCP will be applied to Shin-Hanul unit 1&2 nuclear power plants. The RCP operates in high speed and high pressure condition and only rotating component in the NSSS(Nuclear Steam Supply System). Therefore, the problem of vibration has arisen caused by the hydraulic forces of the working fluid. These forces can influence on the stability characteristics for entire RCS(Reactor Coolant System) loop, and can act as significant destabilizing forces. In this study, vibration evaluation of the pump shaft of development RCP estimated under normal operation and over speed conditions. In order to predict the vibration characteristics and dynamic behavior, modal analysis, critical speed analysis and unbalance response spectrum analysis were performed.

  • PDF