• 제목/요약/키워드: Power series

검색결과 2,984건 처리시간 0.032초

Autolanding Mission Planning of the IT Convergence Hoverable UAV (IT 융합 회전익 무인항공기의 자동 착륙 임무수행)

  • Jung, Sunghun;Kim, Hyunsu
    • Journal of the Korea Convergence Society
    • /
    • 제8권6호
    • /
    • pp.9-16
    • /
    • 2017
  • Researchers are now faced with a limited flight time of the hoverable UAV due to the sluggish technological advances of the Li-Po energy density and try to find a bypassing solution for the fully autonomous hoverable UAV mission planning. Although there are several candidate solutions, automated wireless charging is the most likely and realistic candidate and we are focusing on the autolanding strategy of the hoverable UAV in this paper since it is the main technology of it. We developed a hoverable UAV flight simulator including Li-Po battery pack simulator using MATLAB/Simulink and UAV flight and battery states are analyzed. The maximum motor power measured as 1,647 W occurs during the takeoff and cell voltage decreases down to 3.39 V during the procedure. It proves that the two Li-Po battery packs having 22 Ah and connected in series forming 12S1P are appropriate for the autolanding mission planning.

Performance improvement of multiuser detection using antenna array in CDMA base station

  • Nam, Jong-Gil;Lee, Weon-Chul
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • 제25권3B호
    • /
    • pp.472-486
    • /
    • 2000
  • This paper analysis the performance of joint receiving structure consisting of the decorrelating multiuser detection and beamfromenr-RAKE receive for DS-CDMA communication systems. In asynchronous transmission as the number of simultaneous users increase. the capacity of CDMA system becomes severly reduced due to the nonideal orthogonality between user-assigned PN sequences and improper power control. Accordingly, the CDMA receiving system becomes vulnerable to the multiple access interferences and the near-far problem under multipath fading channel environment. To withstand these undesired performance degradations, this paper proposes the new type of multiuser detection which has a form of the hybrid structure of concatenating beamformer-RAKE receiver and decorrelating multiuser detection. the beam former-RAKE receiver performs temporal and spatial diversity combining with alleviating fading effect and suppressing undesired interferences, and the multiuser detection plays a role of making the receiver robust to the near-far problem. Regarding the individual merit on the usage of either multiuser detection or beamformer-RAKE receiver, the hybrid one is expected to produce the enhanced performance in multipath fading CDMA channel. However major drawback of using decorrelating multiuser detection for practical deployment is arised from its computational complexity , which is exponentially increased as more number of users and transmitted symbols involve. To diminish the computational complexity, this paper exploits an efficient block Toeplitz inversion technique using matrix Levinson polynomial will be introduced. And this paper provided the mathematical analysis to show the efficiency of the proposed joint structure under the multipath propagation environment. And results of a series of exhaustive computer simulations are presented in order to demonstrate the overall performance of the proposed hybrid structure in multipath fading CDMA channel.

  • PDF

The Effect of Qigong on the Health Promotion in Post-mastectomy Women (기공(氣功)이 유방절제술을 받은 여성의 건강증진에 미치는 영향)

  • Kim, Yi-Soon;Kim, Gyeong-Cheol;Kwak, Yi-Sub;Lee, Hai-Woong
    • Journal of Society of Preventive Korean Medicine
    • /
    • 제14권3호
    • /
    • pp.37-49
    • /
    • 2010
  • Objective : Qigong has been reported as an effective for post-mastectomy women. It consists of a series of postures combined with slow, smooth, graceful movements, and is considered a low intensity exercise. In this study, a specialist of Qigong developed a Qigong program for post-mastectomy women in a community. The object of this research is to evaluate the effect of Qigong on a subjective symptom scale, on the grade of discomfort and pain in everyday life, BMI, fat(%), muscular strength, shoulder joint movement, in post-mastectomy women. Methods : The study used a non-equivalent control group non-synchronized design. The experimental group received a Qigong 3 times a week for 12 weeks from September 7th to December 28th in 2009. The subjects were 40 patients are divided into 25 persons in experimental groups and 15 persons in contrastive group. The data were analyzed with descriptive statistics, chi-square test, t-test, Mann-Whitney U test. A P-value less than .05 was considered significant by 2-tailed test. All statistical analyses were performed with SPSS win(ver 12.0). Results : The results were as follows : The score in the subjective symptom(p=.040), and score of anxiety (p=.024), fat(%)(p=.007) were significantly decreased after Qigong program. The values for shoulder flexibility (left : p=.010, right : p=.008), and Muscular strength(grip power)(left : p=.021, right : p=.029) significantly increased after Qigong program. And Flexion(left ; p=.029), Extension(left : p=.001, right : p=.038), Adduction(left ; p=.001, right ; p<0.001) were also significantly increased after Qigong Conclusions : The Qigong is an effective health promotion program for post-mastectomy women.

Effect of Initial Volume of Hard Water and Contact Time on the Reduction of Calcium Ion Concentration using High Voltage Impulse Technique (고전압 임펄스 기술을 활용한 경도 제거에서 경수의 초기부피와 인가시간이 칼슘이온 농도에 미치는 영향)

  • Cho, Seung-Yeon;Kim, Tae-Hui;Chang, In-Soung;Hong, Woong-ki;Lee, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제66권7호
    • /
    • pp.1066-1071
    • /
    • 2017
  • Recently high voltage impulse (HVI) technique has been extensively studied for desalting processes to control the $CaCO_3$ scale formation in industrial water practices such as power plant, boiler, and heat exchange operations. Investigation of the operational parameters for the HVI is important, however, those had not been reported yet. In this study, the effect of initial feed volume and contact time on reduction of calcium ion concentration by the HVI technique was investigated. Initial feed volumes of artificial hard water which contained 100 mg/L of $Ca^{2+}$, were set to 1, 2, and 3 L respectively. After 24hr of HVI contact with 12kV, $Ca^{2+}$ ion was reduced to 50, 29 and 19 % of their initial concentration, indicating that calcium removal increased as initial feed volume decreased. This implies the applied HVI pulse energy per unit mass of calcium is important parameter determining overall desalting efficiency. A series of extended operations of HVI up to 30 days verified the long term stability of the HVI system. The calcium ion declined to 40 mg/L after 2~3 days, and further reduction of calcium was not achieved, indicating that optimum operation time could be 2~3 days under these experimental conditions. Consequently, it was confirmed that the important operational parameter of HVI technique is initial feed volume and contact time as well as the applied voltage that was already proven in the previous study.

A Self-Powered RFID Sensor Tag for Long-Term Temperature Monitoring in Substation

  • Chen, Zhongbin;Deng, Fangming;He, Yigang;Liang, Zhen;Fu, Zhihui;Zhang, Chaolong
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.501-512
    • /
    • 2018
  • Radio frequency identification (RFID) sensor tag provides several advantages including battery-less operation and low cost, which are suitable for long-term monitoring. This paper presents a self-powered RFID temperature sensor tag for online temperature monitoring in substation. The proposed sensor tag is used to measure and process the temperature of high voltage equipments in substation, and then wireless deliver the data. The proposed temperature sensor employs a novel phased-locked loop (PLL)-based architecture and can convert the temperature sensor in frequency domain without a reference clock, which can significantly improve the temperature accuracy. A two-stage rectifier adopts a series of auxiliary floating rectifier to boost its gate voltage for higher power conversion efficiency. The sensor tag chip was fabricated in TSMC $0.18{\mu}m$ 1P6M CMOS process. The measurement results show that the proposed temperature sensor tag achieve a resolution of $0.15^{\circ}C$/LSB and a temperature error of $-0.6/0.7^{\circ}C$ within the range from $-30^{\circ}C$ to $70^{\circ}C$. The proposed sensor tag achieves maximum communication distance of 11.8 m.

Design of a Dual-Band Switch with 2.4[GHz]/5.8[GHz] (2.4[GHz]/5.8[GHz] 이중대역 SPDT 스위치 설계)

  • Roh, Hee-Jung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • 제22권8호
    • /
    • pp.52-58
    • /
    • 2008
  • Ths paper describes the Dual-band switch which was proposed new structure that could improved the specification of broadband and designed by the optimized structure through simulation. The Dual-band switch with 2.4[GHz]/5.8[GHz] that can apply to 802.11a/b/g system that is commercialized present was studied to get a new structure with higher power, high isolation. The transmitter of switch was designed to operate a parallel switching element with stack structure of two FET. The receiver designed to have asymmetry structure that insert series FET in addition to basic serial/parallel FET. SPDT(Single Pole Double Throw) Tx/Rx FET switch is a device that can do switching from a port of input to two port of output. The fabricated SPDT switch has the characteristic of insertion loss of a below -3[dB] form DC to 6[GHz] and the isolation of a below -30D[dB](Rx mode).

Sustain Driver and Reset Circuit for Plasma Display (플라즈마 디스플레이를 위한 서스테인 및 리셋 회로)

  • Kang, Feel-Soon;;Park, Jin-Hyun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.685-688
    • /
    • 2005
  • An efficient sustain driver and a useful reset circuit composition technique are proposed for plasma display panel drive. The proposed sustain driver uses a series resonance between an external inductor and a panel to recover the energy dissipated by a capacitive displacement current of PDP. It consists of four switching devices, an inductor, and external capacitors, which supply sustain voltage sources. Although the amplitude of an input voltage source is twice as high as that of conventional sustain drivers, average voltage stress imposed on power switching devices is nearly same in their values. Moreover, the input voltage source can be directly applied for the use of a reset voltage source. Owing to this scheme, the proposed sustain driver and the embedded reset circuit have a simple configuration. The operational principle and design example are given with theoretical analyses. The validity of the proposed drive system is verified through experiments using a prototype equipped with a 7.5-inch-diagonal AC plasma display panel.

  • PDF

A Study on the Deterioration Diagnosis of 600V Shielded Twisted Pair Control/Measurement Cable using Resonance Frequency (케이블 공진을 이용한 600V 제어/계측용 꼬임쌍선 차폐 케이블의 열화상태 진단에 대한 연구)

  • Shin, JaeYoung;Kim, KwangHo;Nah, WanSoo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제64권12호
    • /
    • pp.1768-1775
    • /
    • 2015
  • Recent major domestic facilities, such as nuclear power plants, many control cables are installed and are degraded by long-term use, but research on deterioration diagnosis is lacking. In the event of a fault in the cable due to deterioration can be developed into a major accident such as the main plant is stopped, so the deterioration diagnostic techniques of high reliability for the cable is required. In this paper, proposes a methodology using a cable resonance that can effectively diagnose the deterioration of the cable. Prior to the test, we developed a setup for stable measuring the characteristics of the cable and it verified the suitable of the measurement set-up in terms of interactivity and reliability, also measured S-parameters applying verified measurement set-up to the cables that deterioration degree is different. Then, we had amplified the difference in resonance frequency between the healthy state and the deteriorated state using connection in a series of measured S-parameters. In a result from the method, we have verified that the more deteriorate the cables is, the more decrease the resonance frequency is. Measured results are justified by inducing the resonance frequency calculation of the cable from the S- parameters represented by the hyperbolic function formula. VNA(Vector Network Analyzer) for S-parameter measurements used in this study is Agilent E5061B and shielded twisted-pair cables was used for deterioration diagnostic test.

Effect of Process Variation of Al Grid and ZnO Transparent Electrode on the Performance of Cu(In,Ga)Se2 Solar Cells (Al 그리드와 ZnO 투명전도막 의 공정변화에 따른 Cu(In,Ga)Se2 박막태양전지의 특성 연구)

  • Cho, Bo Hwan;Kim, Seon Cheol;Mun, Sun Hong;Kim, Seung Tae;Ahn, Byung Tae
    • Current Photovoltaic Research
    • /
    • 제3권1호
    • /
    • pp.32-38
    • /
    • 2015
  • CIGS solar cell consisted of various films. In this research, we investigated electrode materials in $Cu(In,Ga)Se_2$ (CIGS) cells, including Al-doped ZnO (ZnO:Al), intrinsic ZnO (i-ZnO), and Al films. The sputtered ZnO:Al film with a sputtering power at 200W showed the lowest series resistance and highest cell efficiency. The electrical resistivity of the 200-W sputtered ZnO:Al film was $5.2{\times}10^{-4}{\Omega}{\cdot}cm$ by the rapid thermal annealing at $200^{\circ}C$ for 1 min. The electrical resistivity of i-ZnO was not measurable due to its high resistance. But the optical transmittance was highest with less oxygen supply and high efficiency cell was achieved with $O_2/(Ar+O_2)$ ratio was 1% due to the increase of short-circuit current. No significant change in the cell performance by inserting a Ni layer between Al and ZnO:Al films was observed.

New formula in domination theory and it's application for reliability analysis (Domination이론에서의 새로운 식과 이의 신뢰성계산에 대한 적용)

  • 이광원;이일재;강신재
    • Journal of the Korean Society of Safety
    • /
    • 제11권1호
    • /
    • pp.16-26
    • /
    • 1996
  • In a series of original papers, [1-17] efficient methods and algorithms have been presented, for the exact solution of many reliability problems represented by binary networks. A starting point of these methods was the concept of domination, firstly introduced in ,elation with reliability problems in [2]. It's application to directed networks resulted in the development of a topological formula for the classical problem of the two terminal reliability. This result was extended later to the all-terminal and the k-terminal reliability problems. All papers mentioned above use a path oriented representation for the network topology. In practical applications, however, it is common and often advantageous to work with cut sets. This article considers the Domination theory for reliability problem of a network. Some topological formula are derived and the power and the application of this formula are shown through the alternative proof of topological formula of A. Satyanarayana [2].

  • PDF