• Title/Summary/Keyword: Power series

Search Result 2,993, Processing Time 0.032 seconds

A New Control Scheme of the Line-Interactive UPS Using the Series Active Compensator (직렬 능동 보상기를 이용한 Line-Interactive UPS의 새로운 제어 기법)

  • Jang, Hoon;Lee, Woo-Cheol;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.8
    • /
    • pp.405-412
    • /
    • 2003
  • This paper presents a three-phase Line-Interactive uninterruptible power supply (UPS) system with series-parallel active power-line conditioning capabilities, using synchronous reference frame (SRF) based controller, which allows an effective power factor correction, source harmonic voltage compensation, load harmonic current suppression, and output voltage regulation. The three-phase UPS system consists of two active power compensator topologies. One is a series active compensator, which works as a voltage source in phase with the source voltage to have the sinusoidal source current and high power factor under the deviation and distortion of the source voltage. The other is a parallel active compensator which works as a conventional sinusoidal voltage source in phase with the source voltage, providing to the load a regulated and sinusoidal voltage with low THD (total harmonic distortion). The control algorithm using SRF method and the active power flow through the Line-interactive UPS systems are described and studied. The simulation and experimental results are depicted in this paper to show the effect of the proposed algorithm.

Low Power SAR ADC with Series Capacitor DAC (직렬 커패시터 D/A 변환기를 갖는 저전력 축차 비교형 A/D 변환기)

  • Lee, Jeong-Hyeon;Jin, Yu-Rin;Cho, Seong-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.90-97
    • /
    • 2019
  • The charge redistribution digital-to-analog converter(CR-DAC) is often used for successive approximation register analog-to-digital converter(SAR ADC) that requiring low power consumption and small circuit area. However, CR-DAC is required 2 to the power of N unit capacitors to generate reference voltage for successive approximation of the N-bit SAR ADC, and many unit capacitors occupy large circuit area and consume more power. In order to improve this problem, this paper proposes SAR ADC using series capacitor DAC. The series capacitor DAC is required 2(1+N) unit capacitors to generate reference voltage for successive approximation and charges only two capacitors of the reference generation block. Because of these structural characteristics, the SAR ADC using series capacitor DAC can reduce the power consumption and circuit area. Proposed SAR ADC was designed in CMOS 180nm process, and at 1.8V supply voltage and 500kS/s sampling rate, proposed 6-bit SAR ADC have signal-to-noise and distortion ratio(SNDR) of 36.49dB, effective number of bits(ENOB) of 5.77-bit, power consumption of 294uW.

Time Series Analysis of Maximum Electrical Power using the TISEAN package (TISEAN 패키지를 이용한 전력 수요 시계열 분석)

  • Choo, Yeon-Gyu;Park, Jae-Hyeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.803-806
    • /
    • 2012
  • On this paper, various analysis methods has been applied to analyze and forecast the maximum electrical power needs, which is regarded as a nonlinear dynamic system. To understand the characteristic of complicated system, we used TISEAN package and evaluate the chaotic characteristic of time series obtained from electrical power demand using it. TISEAN package offers various algorithms and codes to analyze time series of nonlinear system effectively.

  • PDF

Synchronization Strategy of the Points of Turn-Off Time Using the Miller Effect on Connecting the Semiconductor Devices in Series (전력용 반도체 소자의 직렬연결시 밀러효과를 이용한 소호시점 동기화 전략)

  • Sim, Eun-Yong;Seo, Beom-Seok;Hyun, Dong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.596-599
    • /
    • 1991
  • This paper describes a novel switching algorithm of series connected power semiconductors for high voltage applications. In order to improve the reliability and efficiency of high voltage static power converters, we study on the switching characteristics of series connected power semiconductors and then propose "a servo control of snubber capacitor value" for the dynamic voltage balancing under turn-off state in series connected power semiconductors. Finally, we illustrate the validity of this algorithm by computer simulation and experimental results.

  • PDF

ON GENERALIZED KRULL POWER SERIES RINGS

  • Le, Thi Ngoc Giau;Phan, Thanh Toan
    • Bulletin of the Korean Mathematical Society
    • /
    • v.55 no.4
    • /
    • pp.1007-1012
    • /
    • 2018
  • Let R be an integral domain. We prove that the power series ring R[[X]] is a Krull domain if and only if R[[X]] is a generalized Krull domain and t-dim $R{\leq}1$, which improves a well-known result of Paran and Temkin. As a consequence we show that one of the following statements holds: (1) the concepts "Krull domain" and "generalized Krull domain" are the same in power series rings, (2) there exists a non-t-SFT domain R with t-dim R > 1 such that t-dim R[[X]] = 1.

A Novel Series Active Power Filter for Harmonic Reduction of 3-Phase 3-Wire/4-Wire System (3상 3선/4선식 전력계통의 고조파 저감을 위한 새로운 직렬형 능동 필터 시스템)

  • Kim, Myoung-Hyun;Lim, Seung-Won;Han, Yoon-Seok;Kim, Young-Seok;Won, Chung-Yuen;Choi, Se-Wan
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.349-351
    • /
    • 1999
  • This paper presents a new control algorithm for series active power filters that are applied to 3-phase 3-wire and 3-phase 4-wire systems with capacitive loads. It is difficult to reduce harmonic currents in neutral lines of the 3-phase 4-wire systems using conventional series active power filter control methods. 3-phase 4-wire series active power filter systems using the proposed method in this study lower neutral line harmonics. Simulation was carried out to verify the algorithm.

  • PDF

A Study on the Series Active Power Filter for Harmonic Reduction and Unbalanced Source Voltage Compensation (전류 고조파와 불평형 전원 전압 보상을 위한 직렬형 능동전력필터에 관한 연구)

  • Oh, Jae-Hoon;Han, Yoon-Seok;Kim, Young-Seok;Won, Chung-Yuen;Choi, Se-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.191-194
    • /
    • 2001
  • In this paper, we propose a series active power filter control method to compensate current harmonics and unbalanced source voltage. The system is composed of series active power filter and shunt passive filer that are tuned 5th and 7th harmonics. In this conventional system, series active power filter complements drawbacks of the shunt passive filter, namely improves harmonic compensation characteristics, and compensates unbalanced source voltage. In the proposed algorithm, compensation voltage for harmonic reduction is calculated by performance function, and compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. So, ultimate compensation voltage is sum of those two compensation voltages. By computer simulation, we verify the excellency of proposed method.

  • PDF

Grid-friendly Control Strategy with Dual Primary-Side Series-Connected Winding Transformers

  • Shang, Jing;Nian, Xiaohong;Chen, Tao;Ma, Zhenyu
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.960-969
    • /
    • 2016
  • High-power three-level voltage-source converters are widely utilized in high-performance AC drive systems. In several ultra-power instances, the harmonics on the grid side should be reduced through multiple rectifications. A combined harmonic elimination method that includes a dual primary-side series-connected winding transformer and selective harmonic elimination pulse-width modulation is proposed to eliminate low-order current harmonics on the primary and secondary sides of transformers. Through an analysis of the harmonic influence caused by dead time and DC magnetic bias, a synthetic compensation control strategy is presented to minimize the grid-side harmonics in the dual primary side series-connected winding transformer application. Both simulation and experimental results demonstrate that the proposed control strategy can significantly reduce the converter input current harmonics and eliminates the DC magnetic bias in the transformer.

Voltage Control in a Novel Three-Phase Line Interactive UPS System with Parallel-Series Active Power Line Conditioning Capabilities using AC Line Reactor (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스뎀의 전압제어)

  • Ji, Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1072-1077
    • /
    • 2006
  • In this paper a novel 3-phase line interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) is proposed. And the strategy of voltage control in proposed UPS system is explained. The objective of voltage control in parallel(shunt) and series PWM VSC of proposed UPS system is to guarantee satisfactory characteristics in steady state and transient state.

  • PDF

Comparative Study on Transient Stability Improving Capability of Series and Shunt Compensation (비용함수에 의한 직병렬보상장치의 과도안정도 향상 특성 비교)

  • Choi, Kyu-Hyoung;Jeoug, Chang-Yang;Oh, Tae-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.655-657
    • /
    • 1996
  • The objective of this paper is to compare the series and shunt approaches of controlled reactive power compensation to improve power system transient stabilities. Including main circuit considerations of series and shunt compensators, application aspects are thought to have major impacts on efficiency and economy of the installation of the compensators. The concept is studied by means of EMTP simulations on one machine-Infinite Bus Test System which consists of a 612MVA steam turbin generator and transformer and double circuit 345KV transmission line. Idealized dynamic models of Thyristor Controlled Series Compensation and Shunt Compensation are used for the comparative study of the series and shunt compensation approach to damp power system oscillations.

  • PDF