• Title/Summary/Keyword: Power sequence control

Search Result 278, Processing Time 0.025 seconds

Characteristic of Induction Motor Drives Fed by Three Leg and Five Leg Inverters

  • Talib, Md. Hairul Nizam;Ibrahim, Zulkifilie;Rahim, Nasrudin Abd.;Hasim, Ahmad Shukri Abu
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.806-813
    • /
    • 2013
  • This paper aims to compare the performance of three phase induction motor drives using Five Leg Inverter (FLI) and Three Leg Inverter (TLI) configurations. An Indirect Field Oriented Control (IFOC) method using a TLI is well established and incorporated for high performance speed drives in various industries. The FLI dual motor drive system on the other hand shows good workability in the independent control of two induction motor drives simultaneously. In this experiment, the IFOC method is utilized for both drive systems, and Space Vector Pulse Width Modulation (SVPWM) is used to generate pulses for both inverters. For the FLI, the Double Zero Sequence (DZS) Injection technique is used to generate the modulation signal. The complete experiment setup is done by using a DSpace 1103 controller board. The individual motor performances are analyzed using similar schemes, equipment setups and controller parameter values. The results show similar speed performance response capability between the single motor operation using a TLI system and the two motor operation using a FLI system based on the variable speed range either in forward or reverse operation. They also show similar load rejection abilities. However, the single motor with a TLI has a better power quality aspect such as ripple current and total harmonics distortion (THD).

The Mapping Theory between Current/Voltage and Instantaneous Powers in Three-phase Systems (3상 계통에서 전류/전압과 순시전력간의 맵핑이론)

  • 김효성;최재호
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.228-232
    • /
    • 1997
  • The relation between instantaneous active/reactive powers and currents is defined by voltage mapping matrix in three-phase four-wire systems. Control strategies for an active filter without energy storage components are proposed on the basis of mapping matrices. It can compensate for the zero-sequence current, irrespectively of whether or not a zero-sequence voltage exists in a three-phase four-wire system.

  • PDF

Drives and Motion Control Teaching based on Distance Laboratory and Remote Experiments

  • Vogelsberger, Markus A.;Macheiner, Peter;Bauer, Pavol;Wolb, Thomas M.
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.579-586
    • /
    • 2010
  • This paper presents the organisation and the technical structure of a remote controlled laboratory in the field of high dynamic drives and motion control. It is part of the PEMCWebLab project with the goal of providing students with practical experience on real systems in the field of power electronics and drives. The whole project is based on clear targets and leading ideas. A set of experiments can be remotely performed on a real system to stepwise identify a two axes positioning system and to design different cascaded control loops. Each single experiment is defined by its goals, the content of how to achieve them, and a verification of the results as well as the achieved learning outcomes. After a short description of the PEMCWebLab project, the structure of the remote control is presented together with the hardware applied. One important point is error handling as real machines and power electronics are applied. Finally, a selection of experiments is presented to show the graphical user interface and the sequence of the laboratory.

Unified Active Power Filter Compensating For Source Voltage Unbalance/Current Harmonics and Power Factor Simultaneously (전원 전압의 불평형과 고조파 전류 및 역률을 동시에 보상하는 통합형 능동 전력필터)

  • Lee, Jong-Kun;Seok, Jul-Ki;Lee, Dong-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.103-105
    • /
    • 2004
  • In this paper, a novel control scheme compensating for source voltage unbalance and current harmonics and power factor simultaneously in unified active power filter systems combined with shunt passive filters is proposed, where no low/high-pass filter are used in deriving the reference voltage for compensation. Using digital all-pass filters, the phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage. The amplitude of d-axis current in a series filter is controlled as zero for power factor correction. The validity of the proposed control scheme has been verified by experimental results.

  • PDF

A Speed Sensorless Vector Control Using the Zero Sequence Third Harmonic Voltages (영상부 3고조파를 이용한 유도전동기의 속도센서없는 벡터제어)

  • 최정수;유완식;김영석
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.388-394
    • /
    • 1998
  • In this paper, we propose a speed sensorless control of the saturated induction motor using the zero sequence third harmonic voltages and a compensation method of the stator resistance variations. The air-gap flux of the saturated induction motor contains the space harmonic components rorating synchronous frequency. As a function of the air-gap flux saturation, the dominant third harmonic voltage is used to compensate the non-linear variations of the mutual inductance depending on the saturation level of the motor. and also the stator resistance variations can be measured with the phase angle between the voltage vector and the zero sequencial voltages. The validity of the proposed compensation scheme in the speed sensorless control using rotor flux observer is verified by simulations.

  • PDF

Optimized PWM Switching Strategy for an Induction Motor Voltage Control

  • Lee, Hae-Hyung;Hwang, Seuk-Yung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.527-533
    • /
    • 1998
  • An optimized PWM switching strategy for an induction motor voltage control is developed and demonstrated. Space vector modulation in voltage source inverter offers improved DC-bus utilization and reduced commutation losses, and has been therefor recognizedas the perfered PWM method, especially in the case of digital implementation. Three-phase invertor voltage control by space vector modulation consists of switching between the two active and one zero voltage vector by using the proposed optimal PWM algorithm. The prefered switching sequence is defined as a function of the modulation index and period of a carrier wave. The sequence is selected by suing the inverter switching losses and the current ripple as the criteria. For low and medium power application, the experimental results indicate that good dynamic response and reduced harmonic distortion can be achieved by increasing switching frequency.

  • PDF

Performence Characteristics and Analysis Effect of Maximum Power Saving Device in Metal Parts Heat Treatment Company (금속 부품 열처리업체의 최대전력절감장치 동작 특성 및 효과 분석)

  • Chang, Hong-Soon;Han, Young-Sub;Hwang, Ik-Hwan;Seo, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.6
    • /
    • pp.40-44
    • /
    • 2014
  • In this paper, maximum power is the lowering device using the facility's energy use and peak load electricity through analyzing attitude should like to make it reduce its power base rate. Simulator to manage the demand for power, a maximum electric power base power from electronic watt-hour meters by a device's signal, predictive power, the current power by computing the goal of power for less than Maximum peak power and peak shift, so that you can manage, and peak York, which role you want a cut Metal heat treatment result which analyzes the data, demand for electricity company over the years of analyzing the characteristics of each load, and effects and Reducing power consumption device every month identified seven Sequence control to the load system and successful power control is about showing that the defined goals.

A Study on TCR Control Strategy in Unbalanced Load (3상 불평형 부하를 고려한 TCR 제어기법에 관한 연구)

  • Park, Chang-Joo;Park, Ki-Won;Choi, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1094-1097
    • /
    • 2001
  • The control method of Thyristor-controlled Reactor(TCR) is described in this paper for compensating the poor power factor, unbalanced and/or nonlinear load. Also, auxiliary controller such as DC current and power-factor controller is described. The reference current of TCR is calculated from the active and reactive current components for each of the positive and negative sequence components in the load currents. This reactive power control technique was verified by Matlab Simulink and 33Kvar TCR simulator, and will be used in 4.3Mvar TCR system, which will be installed next year at R-Tech Co., located in Po-Hang.

  • PDF

A Low Poorer Resource Allocation Algorithm Based on Minimizing Switching Activity (스위칭 동작 최소화를 통한 저 전력 자원할당 알고리즘)

  • 신무경;인치호;김희석
    • Proceedings of the IEEK Conference
    • /
    • 2001.06b
    • /
    • pp.121-124
    • /
    • 2001
  • This paper proposed resource allocation algorithm for the minimum switching activity of functional unit in high level synthesis process as like DSP which is circuit to give many functional unit. The resource allocation method after scheduling use the power function calculating average hamming distance and switching activity of the between two input. First of all, the switching activity is calculated by the input value after calculating the average hamming distance between operation. In this paper, the proposed method though high If level simulation find switching activity in circuit each functional unit exchange for binary sequence length and value bit are logic one value. To use the switching activity find the allocation with minimal power consumption, the proposed method visits all control steps one by one and determines the allocation with minimal power consumption at each control step. As the existing method, the execution time can be fast according to use the number of operator and max control step. And it is the reduction effect from 6% to 8%.

  • PDF

A Study on TCR Control Strategy in Hot Rolled Mill at POSCO (열연공장 TCR용 FC 설계기술 개발)

  • 이왕하;박기원;박병주;김덕규
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.10
    • /
    • pp.577-583
    • /
    • 2003
  • The control method of Thyristor Controlled Reactor(TCR) is described in this paper for compensating the poor power factor, unbalanced and/or nonlinear load. Also, auxiliary controller such as DC current and power-factor controller is described. The reference current of TCR is calculated from the active and reactive Current components for each of the positive and negative sequence components in the load Currents. This reactive power control technique was verified by simulation program and will be used in 5Mvar TCR system, which will be installed next year at hot rolled mill at POSCO, located in Kwang-Yang.