• Title/Summary/Keyword: Power regulation

Search Result 1,327, Processing Time 0.029 seconds

Analysis of the Distribution STATCOM Operating Results for Improving Distribution System Power Quality (전력품질 향상을 위한 배전용 STATCOM 운전결과 분석)

  • 오관일;전영수;박상태;추진부
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.4
    • /
    • pp.377-385
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. The custom power is similar in nature to the concept of FACTS(Flexibel AC Transmission System). By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources. STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, providing reactive power compensation, voltage regulation and mitigation of voltage flicker. It is shown that the STATCOM has clear advantages in areas such as; providing reactive power compensation and improving power factor.

  • PDF

Development of Power Supply Unit for high power GTO driver (대용량 GTO 구동회로용 Power Supply Unit 개발)

  • Cha, J.D.;Yang, H.J.;Hong, S.W.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.609-612
    • /
    • 1996
  • This paper describes a design and implementation of the practical SMPS(Switched Mode Power Supply) with multi-output independent regulation scheme. The designed SMPS is applied to the PSU(Power Supply Unit) of high power GTO drivers for a inverter system. In order to accomplish precise voltage regulations for both turn-on and turn-off bias voltages of the GTO driver, the conventional forward type PWM converter scheme is adopted with the Post Regulator using a Saturable Reactor. Analytic design criteria and control schemes are described for practical applications. Finally, the precise regulation of multi-output voltages is proved by experimental results.

  • PDF

Control of a Three-Phase Voltage-Source PWM Converter with an Extended Operation Region (확장된 동작 영역을 갖는 3상 전압원 PWM 컨버터 제어)

  • 민동기;안성찬;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.9-13
    • /
    • 1997
  • In this paper, the operation regions of a three-phase voltage-source PWM converter are defined: linear modulation region, allowed current region, linear control region, unity power-factor region, and power-factor decreasing region. Particularly, the power-factor decreasing region is first examined and defined as the region where both the sinusoidal input current control and the stable DC link voltage regulation can not be obtained with a unity power-factor operation. To avoid these undesirable effects, the optimal current vector is derived, which ensures the sinusoidal input current and the stable DC link voltage regulation with maximum power-factor available, and, in consequence, it extends the operation region of the PWM converter. The validity of the proposed control scheme is proved by the computer simulation.

  • PDF

Constant Frequency Adjustable Power Active Voltage Clamped Soft Switching High Frequency Inverter using The 4th-Generation Trench-Gate IGBTs

  • Miyauchi T.;Hirota I.;Omori H.;Terai H.;Abdullah Al Mamun;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.236-241
    • /
    • 2001
  • This paper presents a novel prototype of active voltage-clamping capacitor-assisted edge resonant soft switching PWM inverter operating at a constant frequency variable power (VPCF) regulation scheme, which is suitable for consumer high-power induction-heating cooking appliances. New generation IGBT with a trench gate is particularly improved in order to reduce conduction loss due to its lowered saturation voltage characteristics. The soft switching load resonant and quasi-resonant inverter designed distinctively using the latest IGBTs is evaluated from an experimental point of view.

  • PDF

Considerations on the use of a Boost PFC Regulator Used in Household Air-conditioning Systems (over 3kW)

  • Jang Ki-Young;Suh Bum-Seok;Kim Tae-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.589-592
    • /
    • 2002
  • The CCM (Continuous Conduction Mode) boost topology is generally used in the PFC (Power Factor Correction) regulator of household air-conditioning systems. There are three kinds of power devices-bridge rectifier diodes, FRDs (Fast Recovery Diodes), and IGBTs (or MOSFETs) - used In a boost PFC regulator. Selecting the appropriate device is very cumbersome work, specially, in the case of FRDs and IGBTs, because there are several considerations as described below: 1) High frequency leakage current regulation (conducted and radiated EMI regulation) 2) Power losses and thermal design 3) Device cost. It should be noted that there are trade-offs between the power loss characteristic of 2) and the other characteristics of 1) and 3). This paper presents a detailed evaluation by using several types of power devices, which can be unintentionally used, to show that optimal selection can be achieved. Based on the given thermal resistances, thermal analysis and design procedures are also described from a practical viewpoint.

  • PDF

A Study on Power Quality Diagnosis System using Neural NetWorks (전기품질 진단 시스템 개발을 위한 인공 신경망 적용에 관한 연구)

  • Kim, Jin-Su;Kim, Young-Il;Kim, Kwang-Soon;Park, Gi-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1351-1359
    • /
    • 2007
  • In this paper, we have studied the power quality(PQ) diagnosis system with the two methods for PQ diagnosis. One to Apply a regulation value in compliance with mathematics calculation, and the other Automatic identification using Neural network algorithm. Neural network algorithm is used for an automatic diagnosis of the PQ. The regulation proposed by IEEE 1159 Working group is applied for the precision of the diagnosis. In order to divide accurate segmentation, the algorithm for a computer training used the back propagation out of several neural network algorithms. We have configured the proto-type sample by using Labview and a programmed Neural Networks Algorithm using with C. And arbitrary electric Signal generated by OMICRON Company's CMC 256-6 for an efficiency test.

Time domain Simulation of a Secondary Voltage Regulation Model to the Jeju Power System (제주 전력계통 2차 전압제어 모델 구축 및 시모의)

  • Yang, Byeong-Mo;Song, In-Jun;Kim, Yong-Hak;Kwark, No-Hong;Kang, Ji-Won;Jang, Tae-In;Song, Hwa-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.469-470
    • /
    • 2007
  • There are many power system simulation software tools for time-domain performance in power system. This paper reports the results of time-domain simulation for the Jeju Power system with a secondary voltage regulation (SVR) model, developed with both TSAT and PSCAD/EMTDC and evaluates them, which are commercial software tools used for digital simulation of power system. TSAT has not been yet verified because of deficient modelling of components in the time domain performance of KEPCO power system. But PSCAD/EMTDC has been enough verified in our system. So, we need to compare and evaluate TSAT with PSCAD/EMTDC in small power system like Jeju. This paper showed that the results simulated by both TSAT and PSCAD/EMTDC is very similar to each other, so TSAT is able to apply for our KEPCO large power system.

  • PDF

Post-transcriptional Regulation of NK Cell Activation

  • Kim, Tae-Don;Park, Ju-Yeong;Choi, In-Pyo
    • IMMUNE NETWORK
    • /
    • v.9 no.4
    • /
    • pp.115-121
    • /
    • 2009
  • Natural killer (NK) cells play key roles in innate and adaptive immune defenses. NK cell responses are mediated by two major mechanisms: the direct cytolysis of target cells, and immune regulation by production of various cytokines. Many previous reports show that the complex NK cell activation process requires de novo gene expression regulated at both transcriptional and post-transcriptional levels. Specialized un-translated regions (UTR) of mRNAs are the main mechanisms of post-transcriptional regulation. Analysis of posttranscriptional regulation is needed to clearly understand NK cell biology and, furthermore, harness the power of NK cells for therapeutic aims. This review summarizes the current understanding of mRNA metabolism during NK cell activation, focusing primarily on post-transcriptional regulation.

A Design of LDO(Low Dropout Regulator) with Enhanced Settling Time and Regulation Property (정착시간과 레귤레이션 특성을 개선한 LDO(Low Dropout Regulator)의 설계)

  • Park, Kyung-Soo;Park, Jea-Gun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.60 no.3
    • /
    • pp.126-132
    • /
    • 2011
  • A conventional LDO(Low Dropout Regulator) uses one OPAMP and one signal path. This means that OPAMP's DC Gain and Bandwidth can't optimize simultaneously within usable power. This also appears that regulation property and settling time of LDO can't improve at the same time. Based on this idea, a proposed LDO uses two OPAMP and has two signal path. To improve regulation property, OPAMP where is used in the path which qualities DC gain on a large scale, bandwidth designed narrowly. To improve settling time, OPAMP where is used in the path which qualities DC gain small, bandwidth designed widely. A designed LDO used 0.5um 1P2M process and provided 200mA of output current. A line regulation and load regulation is 12.6mV/V, 0.25mV/mA, respectively. And measured settling time is 1.5us in 5V supply voltage.

Analysis of the Hosting Capacity of the Distributed Generation and Voltage Regulation Devices Operation According to Reactive Power Control Scheme of the Inverter-based Distributed Generation (인버터 기반 분산전원의 무효전력 제어 특성에 따른 분산전원의 수용용량 및 전압조정 설비의 운영 계획 분석)

  • Cho, Gyu-Jung;Kim, Ji-Soo;Song, Jin-Sol;Shin, Jae-Yun;Kim, Dong-Hyun;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.7
    • /
    • pp.809-815
    • /
    • 2018
  • Distributed generations (DGs) using renewable energy resources in power systems have been widely integrated, and many of these DGs have intermittency. DGs can significantly affect the overall voltage profile of the system through the reactive power control for a voltage support. Therefore, in the planning stage of the optimal operation and dispatch of voltage regulation devices, DGs' hosting capacity with the reactive power control scheme should be considered. In this paper, we model the IEEE 34-bus test feeder, including all essential equipment. An optimization method is utilized to determine the optimal siting and operation of the voltage regulation devices in the presence of DGs with reactive power control scheme. Finally, we compare the optimal results of the each case to analyze the relationship among the hosting capacity of the DGs and voltage regulation devices operation.