• 제목/요약/키워드: Power ratio

검색결과 6,492건 처리시간 0.035초

스털링 사이클을 기본으로 하는 과급 CI 엔진의 기초 성능 분석 (A Basic Analysis of Performance of Turbo CI Engine based on Stirling Cycle)

  • 배종욱
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제24권5호
    • /
    • pp.76-85
    • /
    • 2000
  • Stirling cycle was actualized as so called ‘hot air engine’. It has been focused again lately as one of measures for exhaust gas emission problem, but as small power engine because of its method of heat addition. Recently marine power plants commenced to meet a stringent environmental restrictions by international convention, Marpol so that diesel engines as main and auxiliarly power plants are urged to be reformed to reduce NOx emission. Author devised a compression ignition engine as a large marine power plants combined with turbo charger based on stirling cycle, and analyzed the performance by means of basic thermodynamic calculation. Analyzed in this paper, were theoretical efficiency, mean effective pressure, required equivalence ratio, gas turbine power ratio, maximum pressure, states of turbo-charger inlet gas and exhaust gas, manifesting that the engine could be proposed as one of the future power plants of marine use.

  • PDF

소형 수직축 풍력발전기 풍동실험시 폐쇄율의 영향 (Effect of Blockage Ratio on Wind Tunnel Testing of Small Vertical-Axis Wind Turbines)

  • 정회갑;이승호;권순덕
    • 한국태양에너지학회 논문집
    • /
    • 제34권3호
    • /
    • pp.98-106
    • /
    • 2014
  • The effect of blockage ratio on wind tunnel testing of small vertical-axis wind turbine has been investigated in this study. Height and rotor diameter of the three blades Darrieus vertical axis wind turbine used in present test were 0.4m and 0.35m respectively. We measured the wind speeds and power coefficient at three different wind tunnels where blockage ratio were 3.5%, 13.4% and 24.7% respectively. The test results show that the measured powers have been strongly influenced by blockage ratio, generally increased as the blockage ratio increases. The maximum power at higher blockage ratio has been obtained at relatively high tip speed ratio compared with that at low blockage ratio. The measured power coefficients under high blockage ratio can be improved from proper correction using the simple correction equation based on blockage factor. In present study, the correction error for power coefficient can be less than 5%, however correction effectiveness reveals relatively poor at high blockage ratio and low wind speed.

Image Independent Driving Power Reduction for High Frame Rate LCD Televisions

  • Nam, Hyoung-Sik;Shim, Jae-Hoon
    • ETRI Journal
    • /
    • 제34권3호
    • /
    • pp.470-473
    • /
    • 2012
  • In this letter, the constant driving power reduction ratio has been achieved for column drivers regardless of the input image by incorporating a new static power reduction scheme into the previous dynamic power reduction method. The measured power reduction ratio is around 50% for a 120 Hz liquid crystal display panel in such cases of still input video and fallback.

디스크 드라이브용 VCM 액추에이터의 전력 소모와 감도비에 관한 연구 (Power Consumption and Sensitivity ratio of VCM-type Actuator for Disk Drive)

  • 김선모;장동섭;윤진욱
    • 한국소음진동공학회논문집
    • /
    • 제14권12호
    • /
    • pp.1207-1222
    • /
    • 2004
  • In this paper, the explicit equations on the power consumption and sensitivity ratio of VCM-type actuator for disk drive are proposed. The power consumption and sensitivity ratio is derived in frequency domain. The power consumption during the track following of the actuator can be described well in frequency domain and it can be used to calculate the total power dissipation of the actuator which is needed to compensate the tracking and focusing errors. Also, the sensitivity ratio of an actuator is derived by using the reference servo of a disk drive and will be used to optimally obtain the performances of the actuator. This sensitivity ratio can persuasively explain the basis of the target performances of the actuator in the considerations of the reference servo. The usefulness of the proposed equations for the sensitivity ratio and power consumption of an actuator is shown by a lot of simulations. In the near future, we will verify the simulation results by experiments.

열병합 발전기 수익 극대화를 위한 열전비 최적화 (Heat-Electric Power Ratio Optimization To Maximize Profit of a Cogeneration Power Plant)

  • 김군회;이재헌;문승재;장택순
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.381-384
    • /
    • 2008
  • This paper presents an operational technique to maximize profit of a cogeneration power plant. To minimize errors in a loss and gain analysis of a cogeneration power plant, the energy sale profit in the cost-based-pool electric power trade market, the heat sale profit, and the supplementary fund profit for electric power industry are taken into consideration. The objective is to optimize the heat-electric power ratio to maximize profit of a cogeneration power plant. Furthermore, the constrained bidding technique to optimize heat-electric power ratiocan be obtained. Profits from of a cogeneration power plant are composed of three categories, such as the energy sale profit in the cost-based-pool electric power trade market, the heat sale profit, and the supplementary fund profit for electric power industry. Profits of a cogeneration power plant are varied enormously by the operation modes. The profits are mainly determined by the amount of constrained heat generation in each trading time. And the three profit categories arecoupled tightly via the heat-electric power ratio. The result of this case study can be used as a reference to a cogeneration power plant under the power trading system considered in this case.

  • PDF

A Heuristic Application of Critical Power Ratio to Pressurized Water Reactor Core Design

  • Ahn, Seung-Hoon;Jeun, Gyoo-Dong
    • Nuclear Engineering and Technology
    • /
    • 제34권1호
    • /
    • pp.68-79
    • /
    • 2002
  • The approach for evaluating the critical heat flux (CHF) margin using the departure from nucleate boiling ratio (DNBR) concept has been widely applied to PWR core design, while DNBR in this approach does not indicate appropriately the CHF margin in terms of the attainable power margin-to-CHF against a reactor core condition. The CHF power margin must be calculated by increasing power until the minimum DNBR reaches a DNBR limit. The Critical Power Ratio (CPR), defined as the ratio of the predicted CHF power to the operating power, is considered more reasonable for indicating the CHF margin and can be calculated by a CPR orrelation based on the heat balance of a test bundle. This approach yields directly the CHF power margin, but the calculated CPR must be corrected to compensate for many local effects of the actual core, which are not considered in the CHF test and analysis. In this paper, correction of the calculated CPR is made so that it may become equal to the DNB overpower margin. Exemplary calculations showed that the correction tends to be increased as power distribution is more distorted, but are not unduly large.

EDFA로 증폭된 고출력 펄스 신호의 소광비 향상 (Improvement of extinction ratio of amplified pulses by incorporating a nonlinear optical loop mirror)

  • 김병준;최현범;이한협;이동한;김대연;권일범
    • 한국광학회지
    • /
    • 제14권2호
    • /
    • pp.189-193
    • /
    • 2003
  • 높은 peak 값의 광 펄스 신호를 얻기 위하여 대역통과 필터(band pass filter)를 사용한 2단 구조 erbium-doped fiber amplifier (EDFA)를 구성하여 125 W peak 값과 32 ㏈ 소광비(extinction ratio)를 갖는 펄스 신호를 얻었다. 이때 pulse off power는 79 ㎽이다. pulse off power를 낮추고 소광비를 높이기 위하여 nonlinear optical loop mirror(NOLM)을 사용하였다. NOLM 을 통과한 펄스 신호는 35 W peak 값과 0.3 ㎽ pulse off power, 50.4 ㏈ 소광비를 갖는다.

수소연료를 이용하는 원자층증착 박막전해질 세라믹연료전지의 초기성능 저하에 관한 연구 (A Study on the Initial Performance Degradation of Hydrogen-Fueled Ceramic Fuel Cell with Atomic Layer-Deposited Thin-Film Electrolyte)

  • 지상훈
    • 한국수소및신에너지학회논문집
    • /
    • 제32권5호
    • /
    • pp.410-416
    • /
    • 2021
  • The initial electrochemical performance of ceramic fuel cell with thin-film electrolyte was evaluated in terms of peak power density ratio, open circuit voltage ratio, and activation/ohmic resistance ratios at 500℃. Hydrogen and air were used as anode fuel and cathode fuel, respectively. The peak power density ratio reduced as ~17% for 40 minutes, which rapidly decreased in the early stage of the performance evaluation but gradually decreased. The open circuit voltage ratio decreased with respect time; however, its time behavior was remarkably different with the reduction behavior of the peak power density ratio. The activation resistance ratio increased as ~15% for 40 minutes, which was almost similar with the time behavior of the peak power density ratio.

Modified Wilkinson Power Divider Using Transmission Lines for Various Terminated Impedances and an Arbitrary Power Ratio

  • Yoon, Young-Chul;Kim, Young
    • Journal of electromagnetic engineering and science
    • /
    • 제19권1호
    • /
    • pp.42-47
    • /
    • 2019
  • This paper introduces a modified Wilkinson power divider that uses uniform transmission lines for various terminated impedances and an arbitrary power ratio. For the designed power ratio, the proposed divider changes only the electrical lengths of the transmission lines between the input and output ports, and those between the output ports and the isolation resistor. In this case, even when various termination impedances of the ports exist, the divider characteristics are satisfied. To verify the feasibility of the proposed divider, two circuits were designed to operate at a frequency of 2 GHz with 2:1 and 4:1 power splitting ratios and various terminated impedances of 40, 70, and $60{\Omega}$ for one circuit, and 50, 70, and $60{\Omega}$ for the other. The measurement and simulation results were in good agreement.

임의 분배 비율의 다중모드간섭 광전력 분배기에 대한 벡터 해석법 (Vector analysis for multimode-interference power splitter with an arbitrary splitting ratio)

  • 김진희;이상선;송석호
    • 한국광학회지
    • /
    • 제13권6호
    • /
    • pp.479-485
    • /
    • 2002
  • 다중모드간섭을 이용한 임의 분배 비율의 광전력 분배기에 대한 벡터 해석법을 제시한다 광전력 분배는 집적 광학의 기초가 되는 부분이며 특히 광전력 비율을 임의로 조절할 수 있다면 많은 응용분야에 유용할 것이다. 본 벡터 해석법은 기존의 다중모드간섭 현상에 대한 해석적 결과를 도식화함으로써 임의 분배 비율의 다중모드간섭 광전력 분배기 설계를 보다 쉽게 할 수 있다는 장점을 가지고 있다.