• Title/Summary/Keyword: Power parameters

Search Result 5,815, Processing Time 0.084 seconds

The Behaviors of the Material Parameters Affecting PCI Induced-Fuel Failure (핵연료봉의 PCI파손에 영향을 미치는 인자들의 거동분석)

  • Sim, Ki-Seob;Woan Hwang;Sohn, Dong-Seong;Suk, Ho-Chun
    • Nuclear Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.241-245
    • /
    • 1988
  • It is very important to investigate the behaviors of the material parameters governing PCI fuel failure during power ramp because PCI fuel failure is considered to be related to the operations limits of power reactors. In this study, the behavior characteristics of the material parameters such as hoop stress, hoop strain, ridge height, creep strain rate and strain energy in cladding were studied as a function of the operating parameters such as power shock and ramp rate. The FEMAXI-IV fuel rod performance analysis code was used for this study.

  • PDF

Investigation of the Voltage Collapse Mechanism in Three-Phase PWM Rectifiers

  • Ren, Chunguang;Li, Huipeng;Yang, Yu;Han, Xiaoqing;Wang, Peng
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1268-1277
    • /
    • 2017
  • Three-phase pulse width modulation (PWM) rectifiers are usually designed under the assumption of ideal ac power supply and input inductance. However, non-ideal circuit parameters may lead to a voltage collapse of PWM rectifiers. This paper investigates the mechanism of voltage collapse in three-phase PWM rectifiers. An analytical stability boundary expression is derived by analyzing the equilibrium point of the averaging state space model, which can not only accurately locate the voltage collapse boundary in the circuit parameter domain, but also reveal the essential characteristic of the voltage collapse. Results are obtained and compared with those of the trial-error method and the Jacobian method. Based on the analysis results, the system parameters can be divided into two categories. One of these categories affects the critical point, and other affects only the instability process. Furthermore, an effective control strategy is proposed to prevent a vulnerable system from being driven into the instability region. The analysis results are verified by the experiments.

Impact of Dynamic Load Model on Short-Term Voltage Stability of Korea Power System and Estimation of Dynamic Load Model Parameters (국내 계통의 단기 전압 안정도에 대한 부하 모델의 영향성 검토 및 부하 모델 파라미터 선정)

  • Moon, Jaemin;Kim, Jae-Kyeong;Hur, Kyeon;Nam, Suchul;Kim, YongHak
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.1
    • /
    • pp.17-24
    • /
    • 2019
  • In this paper, we analyzed the effect of power system load model on the short-term voltage stability analysis results. First, we introduced common load models. We also confirmed that some load models can not represent actual system phenomena even if the model parameters are optimized. Also, we studied about the influences of load parameters and regional characteristics of load model on the sort-term voltage stability of KEPCO power system considering the contingency. The results showed that the importance of selecting a load model was confirmed again. And we recognized about it can be understood that it should reflect the load characteristics of the area near the assumed contingency more accurately.

Systematic Approach of Internal Parameters for Equivalent Electrical-Circuit Modeling(EECM) of a Li4Ti5O12(LTO) cell (Li4Ti5O12(LTO) 배터리 등가회로 모델링을 위한 내부 파라미터 체계적 해석)

  • Lee, Pyeong-Yeon;Yoon, Chang-O;Park, Jin-Hyeong;Kim, Jonghoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.174-181
    • /
    • 2018
  • This study introduces a systematic approach to selecting the internal parameters applied to the equivalent electrical-circuit model (EECM) of a lithium titanium oxide ($Li_4Ti_5O_{12}$; LTO) rechargeable cell. Based on the dynamic characteristic of the cell, a simplified EECM consisting of an open-circuit voltage (OCV), an ohmic resistance, and an RC ladder is fabricated. To select the internal parameters of a simplified EECM, experiments on discharge capacity, OCV, and discharge/charge resistances are performed using hybrid pulse power characterization and direct current internal resistance (DCIR) measurements over the full state-of-charge (SOC) range. The experimental results of the LTO rechargeable cell highlight the importance of correct selection of internal parameters that can reduce EECM errors. This study clearly provides experimental procedures, internal parameters results, and EECM guidelines for adaptive control-based SOC estimation for LTO rechargeable cells.

Efficient Method for Recovering Spectral Reflectance Using Spectrum Characteristic Matrix (스펙트럼 특성행렬을 이용한 효율적인 반사 스펙트럼 복원 방법)

  • Sim, Kyudong;Park, Jong-Il
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.12
    • /
    • pp.1439-1444
    • /
    • 2015
  • Measuring spectral reflectance can be regarded as obtaining inherent color parameters, and spectral reflectance has been used in image processing. Model-based spectrum recovering, one of the method for obtaining spectral reflectance, uses ordinary camera with multiple illuminations. Conventional model-based methods allow to recover spectral reflectance efficiently by using only a few parameters, however it requires some parameters such as power spectrum of illuminations and spectrum sensitivity of camera. In this paper, we propose an enhanced model-based spectrum recovering method without pre-measured parameters: power spectrum of illuminations and spectrum sensitivity of camera. Instead of measuring each parameters, spectral reflectance can be efficiently recovered by estimating and using the spectrum characteristic matrix which contains spectrum parameters: basis function, power spectrum of illumination, and spectrum sensitivity of camera. The spectrum characteristic matrix can be easily estimated using captured images from scenes with color checker under multiple illuminations. Additionally, we suggest fast recovering method preserving positive constraint of spectrum by nonnegative basis function of spectral reflectance. Results of our method showed accurately reconstructed spectral reflectance and fast constrained estimation with unmeasured camera and illumination. As our method could be conducted conveniently, measuring spectral reflectance is expected to be widely used.

Neutronic analysis of control rod effect on safety parameters in Tehran Research Reactor

  • Torabi, Mina;Lashkari, A.;Masoudi, Seyed Farhad;Bagheri, Somayeh
    • Nuclear Engineering and Technology
    • /
    • v.50 no.7
    • /
    • pp.1017-1023
    • /
    • 2018
  • The measurement and calculation of neutronic parameters in nuclear research reactors has an important influence on control and safety of the nuclear reactor. The power peaking factors, reactivity coefficients and kinetic parameters are the most important neutronic parameter for determining the state of the reactor. The position of the control shim safety rods in the core configuration affects these parameters. The main purpose of this work is to use the MTR_PC package to evaluate the effect of the partially insertion of the control rod on the neutronic parameters at the operating core of the Tehran Research Reactor. The simulation results show that by increasing the insertion of control rods (bank) in the core, the absolute values of power peaking factor, reactivity coefficients and effective delayed neutron fraction increased and only prompt neutron life time decreased. In addition, the results show that the changes of moderator temperature coefficients value versus the control rods positions are very significant. The average value of moderator temperature coefficients increase about 98% in the range of 0-70% insertion of control rods.

Analysis of Electrical Characteristics of Shield Gate Power MOSFET for Low on Resistance (차폐형 게이트 구조를 갖는 전력 MOSFET의 전기적 특성 분석에 관한 연구)

  • Kang, Ey-Goo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.2
    • /
    • pp.63-66
    • /
    • 2017
  • This research was about shielded trench gate power MOSFET for low voltage and high speed. We used T-CAD tool and carried out process and device simulation for exracting design and process parameters. The exracted parameters was used to design shieled and conventional trench gate power MOSFET. And The electrical characteristics of shieled and conventional trench gate power MOSFET were compared and analyzed for their power device applications. As a result of analyzing electrical characteristics, the recorded breakdown voltages of both devices were around 120 V. The electric distributions of shielded and conventional trench gate power MOSFET was different. But due to the low voltage level, the breakdown voltage was almost same. And the other hand, the threshold voltage characteristics of shielded trench gate power MOSFET was superior to convention trench gate power MOSFET. In terms of on resistance characteristics, we obtained optimal oxied thickness of $3{\mu}m$.

Power System Oscillations Damping by Robust Decentralized DFIG Wind Turbines

  • Surinkaew, Tossaporn;Ngamroo, Issarachai
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.487-495
    • /
    • 2015
  • This paper proposes a new robust decentralized power oscillation dampers (POD) design of doubly-fed induction generator (DFIG) wind turbine for damping of low frequency electromechanical oscillations in an interconnected power system. The POD structure is based on the practical $2^{nd}$-order lead/lag compensator with single input. Without exact mathematical model, the inverse output multiplicative perturbation is applied to represent system uncertainties such as system parameters variation, various loading conditions etc. The parameters optimization of decentralized PODs is carried out so that the stabilizing performance and robust stability margin against system uncertainties are guaranteed. The improved firefly algorithm is applied to tune the optimal POD parameters automatically. Simulation study in two-area four-machine interconnected system shows that the proposed robust POD is much superior to the conventional POD in terms of stabilizing effect and robustness.

Evaluation of reactor pulse experiments

  • I. Svajger;D. Calic;A. Pungercic;A. Trkov;L. Snoj
    • Nuclear Engineering and Technology
    • /
    • v.56 no.4
    • /
    • pp.1165-1203
    • /
    • 2024
  • In the paper we validate theoretical models of the pulse against experimental data from the Jozef Stefan Institute TRIGA Mark II research reactor. Data from all pulse experiments since 1991 have been collected, analysed and are publicly available. This paper summarizes the validation study, which is focused on the comparison between experimental values, theoretical predictions (Fuchs-Hansen and Nordheim-Fuchs models) and calculation using computational program Improved Pulse Model. The results show that the theoretical models predicts higher maximum power but lower total released energy, full width at half maximum and the time when the maximum power is reached is shorter, compared to Improved Pulse Model. We evaluate the uncertainties in pulse physical parameters (maximum power, total released energy and full width at half maximum) due to uncertainties in reactor physical parameters (inserted reactivity, delayed neutron fraction, prompt neutron lifetime and effective temperature reactivity coefficient of fuel). It is found that taking into account overestimated correlation of reactor physical parameters does not significantly affect the estimated uncertainties of pulse physical parameters. The relative uncertainties of pulse physical parameters decrease with increasing inserted reactivity. If all reactor physical parameters feature an uncorrelated uncertainty of 10 % the estimated total uncertainty in peak pulse power at 3 $ inserted reactivity is 59 %, where significant contributions come from uncertainties in prompt neutron lifetime and effective temperature reactivity coefficient of fuel. In addition we analyse contribution of two physical mechanisms (Doppler broadening of resonances and neutron spectrum shift) that contribute to the temperature reactivity coefficient of fuel. The Doppler effect contributes around 30 %-15 % while the rest is due to the thermal spectrum hardening for a temperature range between 300 K and 800 K.

Electrical Parameter Tests of Synchronous Reluctance Motor

  • Khang, Huynh Van;Hwang, Seon-Hwan;Kim, Jang-Mok;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.211-213
    • /
    • 2007
  • The electrical parameters are used to calculate gains in the current regulator as well as to determine the reference currents of speed controller in various control strategies of Synchronous Reluctance Motors (SynRMs). Many methods of measuring or estimating the electrical parameters of SynRM have been proposed by other authors. But almost papers only measure or estimate in the limited conditions without fully considering the effects of inverter, connecting wire and magnetic saturation. The parameter results are usually different from the real system parameters. The drive performance, therefore, can not be good if using inaccurate parameters. In this paper, several methods used to measure the electrical parameters are introduced. The first method is LCR meter. And then, a method determining inductances by measuring AC current and voltage from AC power supply is presented. A new method with high reliability is proposed to measure the electrical parameters of SynRM. The experiment results verify the effectiveness of the new proposed method.

  • PDF