• Title/Summary/Keyword: Power modelling

Search Result 453, Processing Time 0.021 seconds

PSS Modeling and Cerification for #6 Generator of Boryong T/P (보령 T/P 6호기 PSS 모델링과 검증)

  • Choi, H.K.;Kim, D.J.;Moon, Y.H.;Kim, Y.H.;Yoon, Y.B.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.31-34
    • /
    • 2002
  • It studied modelling about employing analog PSS in domestic 500MW grade standard thermoelectric power plant in this paper. Modeling and parameters were verified by simulation of PSS response characteristics measured in AVR step examination and using power plant system model parameters decided by generator characteristics test. Through this PSS modelling research, contributed in domestic electrical power system small signal stability as that do modelling to be possible exact analysis of power system.

  • PDF

Aero-elastic coupled numerical analysis of small wind turbine-generator modelling

  • Bukala, Jakub;Damaziak, Krzysztof;Karimi, Hamid Reza;Malachowski, Jerzy
    • Wind and Structures
    • /
    • v.23 no.6
    • /
    • pp.577-594
    • /
    • 2016
  • In this paper a practical modelling methodology is presented for a series of aero- servo- elastic- coupled numerical analyses of small wind turbine operation, with particular emphasis on variable speed generator modelling in various wind speed conditions. The following characteristics are determined using the available computer tools: the tip speed ratio as a function of the generator constant (under the assumption of constant wind speed), the turbine coefficient of power as a function of the tip speed ratio (the torque curve is modified accordingly and generator speed and power curves are plotted), turbine power curves and coefficient of power curve as functions of the incoming wind speed. The last stage is to determine forces and torques acting on rotor blades and turbine tower for specific incoming wind speeds in order to examine the impact of the stall phenomena on these values (beyond the rated power of the turbine). It is shown that the obtained results demonstrate a valuable guideline for small wind turbines design process.

Numerical Prediction of NOx in the Nonpremixed Hydrogen-Air Flame using the Quasi-Laminar Reaction Modelling (준충류 근사를 이용한 수소-공기 비예혼합화염의 질소산화물 생성예측)

  • Kim, Seong-Lyong;Jeung, In-Seuck;Yoon, Young-Bin
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.1
    • /
    • pp.131-139
    • /
    • 1999
  • A Numerical Analysis of NOx production in Hydrogen-Air flame is performed using the quasi-laminar reaction modelling. As results, in low global strain rate region, $U_F/D_F\;{\leq}\;50,000$, the quasi-laminar reaction modelling reproduces the experimentally observed EINOx half power scaling that the ratio of EINOx and flame residence time, $L_f^3(D_F^2U_F)$, is proportional to the square root of global strain rate. Thus, it suggests that turbulence-chemistry interaction has a minor impact on the trend of NOx production in low global strain rate region. However, the quasi-laminar reaction modelling predicts the higher temperature and NOx than experimentally observed. This overprediction may be due to the lack of radiation and quasi-laminar reaction modelling.

  • PDF

Fuzzy Control Using A Modified Fuzzy Modelling (개선된 퍼지 모형화 기법에 의한 퍼지 제어)

  • Lee, Sang-Yong;Seo, Jin-Heon
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.349-352
    • /
    • 1991
  • Fuzzy modelling is a useful method when the variation of plant dynamics is large. In the fuzzy modelling by parameter identification, a new method is proposed in the part of premise parameters identification and in expanding MISO system into MIMO system. Using the proposed method, a fuzzy model of the drum boiler of the thermal power plant can be derived. In addition, feedwater control of the drum by fuzzy controller using the fuzzy model, is simulated.

  • PDF

A Study on the Structural Modelling of National Maritime Power System (국가해양력시스템의 구조모델화에 관한 연구)

  • 임봉택;이철영
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 1999.10a
    • /
    • pp.153-161
    • /
    • 1999
  • For composing the structure model of national maritime power system by system structural modelling, in this study, the 50 basic factors are selected by survey of the extensive and thorough literatures on maritime, sea, maritime power and sea power. And the basic factors are classified into 36 component factors by cluster method. The 9 attributes are extracted by the application of the principle component analysis method, one of the factor analysis method in system engineering, to component factors. We defined the attributes composing the national maritime power system by integration the result of this study and existed our studies relate to this topic. Which are showed in table 8. and we showed the structure model of national maritime power system in figure 3. In table 8, the 9 attributes are as follows: the fundamental power of maritime, shipping and port power, naval power, fishing power, shipbuilding power, the power of ocean research and development, dependency on seaborne trade, the protection power of ocean environment and the will and inclination of government.

A Study on the Customer Voltage Characteristic of Distribution System with Large Scale PV (대용량 태양광발전이 연계된 배전계통의 수용가 전압 특성해석에 관한 연구)

  • Kim, Byung-Ki;Ryu, Kyung-Sang;Kim, Chan-Hyeok;Rho, Dae-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • This paper deals with the analysis of the customer voltage characteristic in distribution system interconnected with large scale PV system. There would be many power quality issues which are caused by reverse power flow of PV system interconnected with distribution system. In order to analyze the effect of PV system on the customer voltage, detailed modeling method of distribution system and modified modelling method of PV system are proposed using PSCAD/EMTDC in this paper. So far, less than dozens KW of PV system can be simulated with the existing modelling method. Therefore, a new modeling method which can simulate the large scale PV system is proposed by considering the relationship equation on the phase and voltage in the current control algorithm. From the simulation result of proposed modelling method, it is confirmed that an optimal operation method in distribution system is suggested by analyzing the effect of PV system on customer voltage.

A High Quality Power Factor Correction Converter Based on Half Bride Topology (Half bridge 회로를 기반으로 한 역률개선용 컨버터)

  • 이준영;문건우;정영석;윤명중
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.26-36
    • /
    • 1997
  • An single stage AC/DC converter based on half bridge topology suitable for low power level applications is proposed. The proposed converter has high power factor, low harmonic distortion, and tight output regulations. Asymmetrical control and synchronous rectification are adopted to reduce the switching loss and rectification loss, respectively. The modelling employing average modelling method and detailed analysis are performed to derive the design equations. According to these design equations, a prototype converter has been designed and experimented. This prototype meets the IEC 555-2 regulations with near unity power factor and high efficiency.

  • PDF

Reliability Prediction for the DSP module in the SMART Protection System (일체형 원자로 보호계통의 디지털 신호 처리 모듈에 대한 신뢰도 예측)

  • Lee, Sang-Yong;Jung, Jae-Hyun;Kong, Myung-Bock
    • IE interfaces
    • /
    • v.21 no.1
    • /
    • pp.85-95
    • /
    • 2008
  • Reliability prediction serves many purposes during the life of a system, so several methods have been developed to predict the parts and systems reliability. MIL-HDBK-217F, among the those methods, has been widely used as a requisite tool for the reliability prediction which is applied to nuclear power plants and their safety regulations. This paper presents the reliability prediction for the DSP(Digital Signal Processor) module composed of three assemblies. One of the assemblies has a monitoring and self test function which is used to enhance the module reliability. The reliability of each assembly is predicted by MIL-HDBK-217F. Based on these predicted values, Markov modelling is finally used to predict the module reliability. Relax 7.7 software of Relax software corporation is used because it has many part libraries and easily handles Markov processes modelling.

Modelling and Performance Analysis of UPFC Using EMTP/ATPDraw (EMTP/ATPDraw를 이용한 UPFC구현 및 동작 분석)

  • Jang, Won-Hyeok;Lee, You-Jin;Rhee, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.217-219
    • /
    • 2008
  • Among the Flexible AC Transmission Systems (FACTS) devices, Unified Power Flow Controller (UPFC) is considered as the most powerful and versatile one as it provides simultaneous, real time control of the transmission parameters, voltages, impedances, and phase angles which determine the power flow in AC transmission systems. This paper presents modelling of UPFC and describes its characteristics. The UPFC implemented in this paper is based on Sinusoidal Pulse Width Modulation (SPWM) and Electro-Magnetic Transients Program (EMTP)/ATPDraw is used to model and analyze it. The simulation results confirm advantages of UPFC in operational performance with respect to the steady state Power flow regulation and the transient stability control.

  • PDF