• 제목/요약/키워드: Power meter

검색결과 527건 처리시간 0.025초

고 전력 Source Measurement Unit의 설계 및 제작 (Design and Implementation of High Power Source Measurement Unit)

  • 이상구;백왕기;박종식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.860-863
    • /
    • 2003
  • In this paper high power SMU(Source Measurement Unit) having 50V/1.5A source/measure range has been designed and implemented. The SMU has two operation mode, voltage mode and current mode. The SMU can be used as variable voltage source, variable current source, voltage meter, or current meter. Combining two different unit, output power can be doubled as 100V/1.5A. The developed SMU tan be used many semiconductor testing system and electronic device inspecting system.

  • PDF

공기압 쿠션 실린더의 미터아웃/미터인 속도제어 특성에 관한 연구 (A Study on the Meter-Out and Meter-In Speed Control Characteristics in Pneumatic Cushion Cylinders)

  • 김도태
    • 한국생산제조학회지
    • /
    • 제22권1호
    • /
    • pp.1-7
    • /
    • 2013
  • Pneumatic cylinders are widely used to actuators in automatic equipments because they are relatively inexpensive, simple to install and maintain, offer robust design and operation, are available in a wide range of standard sizes and design alternatives. This paper presents a comparative study among the dynamic characteristics of meter-out and meter-in speed control of pneumatic cushion cylinders with a relief valve type cushion mechanism. Because of the nonlinear differential equations and a requirement for simultaneous iterative solution in a mathematical model of a double acting pneumatic cushion cylinder, a computer simulation is carried out to investigate pressure, temperature, mass flow rate in cushion chamber and displacement and velocity time histories of piston under various operating conditions. It is found that the piston velocity and pressure response in meter-in speed control are more oscillatory than with meter-out those when pneumatic cushion cylinders are driven at a high-speed. In meter-out speed control, the effective area of the flow control valve is larger than that of meter-in, and the supply pressure has to be much higher than the pressure required to move the load because it has also to overcome the back pressure in cushion chamber.

영상처리 기법에 기반한 아날로그 및 디지틀 계기의 자동인식에 관한 연구 (A Study on Analog and Digital Meter Recognition Based on Image Processing Technique)

  • 김경호;진성일;이용범;이종민
    • 전자공학회논문지B
    • /
    • 제32B권9호
    • /
    • pp.1215-1230
    • /
    • 1995
  • The purpose of this paper is to build a computer vision system that endows an autonomous mobile robot the ability of automatic measuring of the analog and digital meters installed in nuclear power plant(NPP). This computer vision system takes a significant part in the organization of automatic surveillance and measurement system having the instruments and gadzets in NPP under automatic control situation. In the meter image captured by the camera, the meter area is sorted out using mainly the thresholding and the region labeling and the meter value recognition process follows. The positions and the angles of the needles in analog meter images are detected using the projection based method. In the case of digital meters, digits and points are extracted and finally recognized through the neural network classifier. To use available database containing relevant information about meters and to build fully automatic meter recognition system, the segmentation and recognition of the function-name in the meter printed around the meter area should be achieved for enhancing identification reliability. For thus, the function- name of the meter needs to be identified and furthermore the scale distributions and values are also required to be analyzed for building the more sophisticated system and making the meter recognition fully automatic.

  • PDF

배전원격관리를 위한 차세대 디지털 적산전력계 개발 (Development of ADWHM(Advanced Digital Watt-Hour Meter) for Remote Management of Distribution Systems)

  • 고윤석;윤상문;서성진;강태규
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권6호
    • /
    • pp.316-323
    • /
    • 2004
  • This paper develops an ADWHM(Advanced Digital Watt-Hour Meter) which integrates and implements the voltage management data record function and the load management data record function in the electronic watt-hour meter. ADWHM is developed based on PIC16F874 which is 8bit micro-controller of RISK type for the easy of programing and maintenance, and electronic power signal processing module is located at front of it to reduce the computing load of processor. Also, a 16kbyte EEPROM is used to record the voltage management data and load management data for a week as well as watt-hour data and USART communication mode is used to transfer data from ADWHM to PC. The accuracy of the voltage and unt measuring for ADWHM is verified by identifying the LCD display values of the ADWHM after the voltage signals of id levels from digital function generator is applied to PT(Potential Transformer) and CT(Current Transformer) output under state which it is separated from real power line. On the its basic functions such as watt-hour data recording function, voltage management data recording function and load management data recording function was verified by showing data for three days among the collected data to PC by RS232C communication from ADWHM which was connected to real power lines for a week.

A Comparative Analysis of Step and Touch Voltages Depending on Two Test Voltage Waveforms

  • Jung, Kwang-Seok;Cha, Sang-Wook;Park, Dae-Won;Kil, Gyung-Suk;Oh, Jae-Geun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권4호
    • /
    • pp.152-155
    • /
    • 2011
  • This paper presents a comparative analysis on step and the touch voltages generated by either a sine and a ring wave voltage generator; this analysis was done as a basic study in order to develop a small and lightweight ground meter. A ring wave generator using pulsed power technology was fabricated; an experimental grounding system specified in Institute of Electrical and Electronics Engineers standards 80 and 81 was installed. The step and the touch voltages, which were measured using comparable a sine and a ring waves in terms of magnitude and frequency, were equal. Using pulsed power technology, the weight of the fabricated ring wave generator could be reduced to one-fifth of that of a sine wave generator. Consequently, if a ground meter adopts the ring wave instead of a sine wave, it will be possible to reduce the weight of a ground meter and improve the efficiency of measurement.

스마트카드 기반의 전력원격검침 프레임워크 (Smart Card based Framework for Electricity AMR)

  • 강환수
    • 한국콘텐츠학회논문지
    • /
    • 제9권7호
    • /
    • pp.121-129
    • /
    • 2009
  • 전력검침은 전력 사용요금을 부과하기 위하여 전력사용량을 측정하는 행위를 말하며, 이를 자동화한 시스템을 전력원격검침(AMR: Automatic Meter Reading)이라 한다. 전력원격검침은 검침 인력을 시스템으로 대체해 원가를 줄이고 고객 서비스를 강화할 수 있는 시스템으로 부각되고 있다. 본 논문에서는 기존의 전력원격검침 모델의 대안으로 스마트카드 기반의 전력원격검침 프레임워크 SCEMS를 제안하고 구현하였다. 제안된 SCEMS 프레임워크는 자바카드 기반의 다기능 스마트카드를 사용하며, 스마트카드에 수집된 자료와 가구의 전력사용 패턴을 활용하여 다양한 요금제를 지원하는 등의 고객서비스를 제공한다. 제안된 원격검침 모델 연구는 전력산업의 환경변화에서 초래할 다원화, 이질화, 복합화에 대한 해결방안이 될 수 있을 것으로 보인다.

AMI 계량데이터의 검증 신뢰성 및 추정 정확도 향상을 위한 VEE 알고리즘 개선 연구 (A VEE Algorithm Improvement Research for Improving Estimation Accuracy and Verification Responsibility of The AMI Meter Data)

  • 이재관;신진호;주용재;노재구;박영배;정남준
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권4호
    • /
    • pp.557-562
    • /
    • 2016
  • 계량데이터 관리 시스템은 수용가에서 검침된 계량데이터를 수집하고 관리하는 시스템이다. 이 시스템에는 검침된 데이터의 오검침과 유효성을 판단하는 검증과 누락된 검침값이나 오검침으로 판단된 구간값을 추정하는 VEE 알고리즘이 있다. 그러나 기존의 VEE 알고리즘은 현장 데이터의 특성을 반영하지 않고 검증하고 추정하기 때문에 그만큼 신뢰성과 정확도가 낮아지는 단점이 있다. 본 논문에서는 검증 신뢰성과 추정 정확도를 향상시킬 수 있는 차세대 VEE 알고리즘을 제안한다.

Real Time Electrical Energy Computing Tool

  • Kumpanya, Danupon;Thaiparnat, Sattarpoom
    • International Journal of Advanced Culture Technology
    • /
    • 제3권1호
    • /
    • pp.113-119
    • /
    • 2015
  • This paper presents a design and implementation of real time electrical energy computing tool to measure and record the electrical energy based on type of detection devices, Hall Effect current sensor and Microcontroller. The tool was installed on the system power supply of the room and compared with kWh meter. Finally, we found that the energy record has error of average power calculating results is 0.077%.

직류 전동기의 속도 토크 제어를 위한 부하 전류 관측기 설계 (The Load Current Observer Design for Torque Control of DC Meter)

  • 서영수;김은기;김용주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.155-158
    • /
    • 2001
  • In this paper, the Load Current Observer Design for 3-phase Voltage Type PWM Converter with DC Meter Load. The sinusoidal input current and unity input power factor are realised based on the estimated source voltage performed by the Load Current Observer using actual currents and DC link voltage.

  • PDF

유도형 적산전력량계의 고조파 민감도 특성 (Characteristics on the Harmonic Sensitivity of Induction Watthour Meter)

  • 장석명;이성호;박영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부A
    • /
    • pp.31-33
    • /
    • 1998
  • The sensitivity of induction watthour meter was reviewed by characteristic tests under the effects of each input harmonics and the variation of power factor of inverter input/output terminal. This paper presents experimental data on the characteristics of induction watthour meter under the effect of harmonics.

  • PDF