Browse > Article
http://dx.doi.org/10.17703/IJACT.2015.3.1.113

Real Time Electrical Energy Computing Tool  

Kumpanya, Danupon (Faculty of Engineering and Architecture Ragamangala University of Technology Suvarnabhumi)
Thaiparnat, Sattarpoom (Faculty of Business Administration and Information Technology Ragamangala University of Technology Suvarnabhumi)
Publication Information
International Journal of Advanced Culture Technology / v.3, no.1, 2015 , pp. 113-119 More about this Journal
Abstract
This paper presents a design and implementation of real time electrical energy computing tool to measure and record the electrical energy based on type of detection devices, Hall Effect current sensor and Microcontroller. The tool was installed on the system power supply of the room and compared with kWh meter. Finally, we found that the energy record has error of average power calculating results is 0.077%.
Keywords
Hall Effect current sensor; Microcontroller; kWh meter;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Datasheet, Introduction to the Atmel ATmega16 Microcontroller, San Jose State University, Dept. of Mechanical and Aerospace Engineering, September 6, 2010.
2 Science & Technology Support High Performance Computing, Introduction to the C Programming Language, Ohio Supercomputer Center,1224 Kinnear Road, Columbus, OH 43212-1163.
3 Brian W. Kernighan, Dennis M. Ritchie, The C Programming Language, Second edition.
4 Honeywell, MICRO SWITCH Sensing and Control. Hall Effect Sensing and Application, Sensing and Control, Honeywell Inc., 11 West Spring Street, Freeport, Illinois 61032.
5 Datasheet, Watt-hour meter, MITSUBISHI Electric, pp. 470-479.