• 제목/요약/키워드: Power line noise

검색결과 490건 처리시간 0.029초

전력IT를 위한 광대역 전력선통신에 관한 연구 (A Study on Broadband PLC for Power IT)

  • 김연수;신재문
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1599-1605
    • /
    • 2011
  • From now on, power line communication was made use of controling using 450 kHz narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. In this paper, analyze the possibility of moving picture transmission for adapting surveillance camera which is among of the application of PLC. To analyze characteristics of channel, estimate the noise and impedance of lab, office, home. In case of noise, there is no problem to communicate each other because of 20 ~ 50 dB gain. In case of impedance, average impedance is about 100 ohm, it satisfy standards of designing modem but because max and min values get out of expectation there are some problem to acquire fully capacity of modems. Its condition is the same as transmission of multimedia data. In this test as more packets, as more handling rate, in lab, for the case that transmit 1,518 byte as the speed of 6 Mbps handling rate is upto 100%, it means possibility of moving picture transmission as the 6 Mbps speed. For delayed time there is no relationship about transmitted packets. As a result, there is no problem about applying surveillance camera via the PLC. And more cameras can work within PLC for considering the number of transmitted frames.

IP기반 가전 제어를 위한 전력선 통신망 채널 특성 추정기법에 관한 연구 (A Systematic Method of Probing Channel Characteristics of Home Power Line Communication Network for IP Based Control of Home Appliances)

  • 안남호;김정근;이재식;장태규;김훈
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제52권12호
    • /
    • pp.696-701
    • /
    • 2003
  • This paper presents a systematic method of probing channel characteristics and communication reliabilities of home power line communication network applied to the Internet accessed control of home appliances. The effects of the three performance deterioating factors, i.e., additive noise, channel attenuation, and intersymbol interference, can be systematically measured by applying the channel probing waveform in the frequency range from 100KHz to 450KHz. Probability of bit error is derived with the probed channel parameters of the signal attenuation, noise and signal-to-interference ratio read in the frequency domain. The agreement between the derived probability of bit error and the measured probability of bit error supports the validity of the proposed approach of probing home power line channel characteristics. The experimental results performed with the constructed test-bed applying the proposed channel probing method also support the feasibility of commercially deploying the PLC modem installed home appliances and their services for the Internet accessed home automation.

전자파 잡음을 이용한 전기설비 불량 검출장치 개발 (Development of the equipment for detecting the poor power facilities by receiving electric noises)

  • 이복규;강성철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1356-1359
    • /
    • 1997
  • There are various methods to detect the faulty electric facilities(esp, insulator) indirectly on power distribution lines at a certain distance apart. This paper describes the proto type equipment to detect a faulty insulator by receiving a electric discharge noises, which are generated with a periodicity of 120Hz.

  • PDF

내잡음성 저속 전력선 모뎀의 구현 (Embodiment of the Power-Line Modem for high noise environment)

  • 여진기;이승민;이흥호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.558-561
    • /
    • 2002
  • In the embodiment of power line modem, the important elements are selection of a suitable line-coupler, choice of a modulation method good for channel environments, and an efficient data coding method etc. In this paper an appropriate modulation method was implemented their results in details and verified by the simulations. The data compensation request techniques that uses error checking was discussed. Finally, application of other modulation method by detection of error rate per bit according to vary of channel error caused by electric equipment that is connected to power line was studied.

  • PDF

기계류의 소음 특성 (Characteristics of Machinery Noise)

  • 강대준;구진회;이재원;권혁제;박형규;김지윤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.904-908
    • /
    • 2008
  • As the various industrial production machinery has come into being by development of industrial technology, the productivity of the basic industrial production machinery has improved and the international competitiveness of the one of Korea has strengthened. However, at the same time, noise from various industrial production machinery disturbs the quiet environment. There are 35 kinds of the noise emission machinery defined in the noise and vibration control act according to the horse power and the number of machinery. These were classified in 1992 through investigation from 1990 to 1991, and the characteristic of the noise emission machinery may be different from the past one. So we need to investigate the characteristics of the noise emitted by machinery to control it rightly. Also we need to investigate the new noise emission machinery which has come into being recently. In this survey, we measured sound intensity of 32 noise emission machinery to calculate the sound power levels of those and investigated the characteristic of the sound power level of those according to the frequency. From the survey, we found that the forging machine, concrete pipe and pile making machine, sawing machine, etc. are the noisy machinery. And the automatic packing machine, sewing machine, centrifuge, etc. are the silent machinery. Also the generator, the concrete pipe and pile making machine, the printing machine, etc. emit the low frequency noise, and the molding machine, the stone cutter, the metal cutter, etc. emit the high frequency noise. Lastly, we intented to propose the proper guide line of classifying noise emission machinery.

  • PDF

ECG신호에서의 전력선 간섭 제거에 관한 연구 (Power line Interference cancelling in the ECG)

  • 남현도;안동준;이철희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 A
    • /
    • pp.308-310
    • /
    • 1992
  • Adaptive noise cancelling using system identification techniques for cancelling power line interference in the electrocardiogram (ECG) is presented. This method is sensitive and self-adjusting to both slow and abrupt changes in the AC interference amplitude and frequency. Computer simulation were done to compare this method with the Lekov's method.

  • PDF

PLC(Power-Line Communication)를 위한 채널 잡음 특성 분석 (The Analysis of Channel Noise Characteristics for Power-Line Communication)

  • 김정훈;김선효;이영철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.232-235
    • /
    • 2001
  • 본 논문은 주파수 범위가 0∼30MHz에서 전력선 통신 채널상에 나타나는 잡음에 대한 실험적인 특성 및 수치계산에 의한 이론적인 근거를 전력선 채널 파라미터의 스펙트럼상의 잡음밀도 측정으로부터 유도하였으며, 거리에 따른 채널 모의실험을 통해서 나타난 잡음 특성을 이론적인 정보전달 범위에서 비교ㆍ분석하였다.

  • PDF

분기관 진동에 의한 피로파괴 (Vibration Related Branch Line Fatigue Failure)

  • 전형식;박보용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1990년도 추계학술대회논문집; 한양대학교, 서울; 24 Nov. 1990
    • /
    • pp.113-124
    • /
    • 1990
  • Tap lines are small branch piping generally less than two inches in diameter. They typically branch off of header piping having a much larger diameter. An example of a common tap line is a 3/4 inch size high point vent or low point drain. Most tap lines have at least one valve near the header tap connection to provide isolation. Two valves are often required for double isolation. A light water reactor(LWR) nuclear power plant will have several hundred tap lines. These lines come in many sizes and shapes and serve numerous functions. A single process piping valve may have three different tap lines associated with it (figure 1). Table 1 delineates the different categories of tap lines. Vibration failures of tap lines are a common occurrence in all industrial plants including nuclear and fossil power plants. These types of failures constitute a significant percentage of all piping related failures. An unscheduled plant shutdown or outage resulting from the failure of a tap line decreases plant reliability and may have a detrimental effect on plant safety. Most tap line vibration failures can be avoided through the use of appropriate routing and support techniques. Standardized designs can be developed for use in a myriad of applications. These designs will not only minimize failures but will also reduce the necessary analysis and installation efforts.

  • PDF

시운전 시험을 통한 한국형 고속전철에 대한 승차감의 분석 (Analysis of Ride Comfort for Korean High Speed Train through On-line Test)

  • 김영국;김석원;박찬경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.549-554
    • /
    • 2003
  • Recently, the ride comfort problem becomes increasingly important because of today's needs for train speedup. The concept of ride comfort is equivocal. Generally, it is defined as the body vibration. The prototype of Korean high speed train (KHST), composed of two power cars, two motorized cars and three trailer cars, has been designed, fabricated and tested by the domestic researchers. In this paper, the ride comfort has been reviewed by the experimental method. The on-line test of KHST has been carried out up to 260km/h in the KTX line and proved that KHST has no problems from the viewpoint of the comfort ride at this speed. And the ride index lot KHST has been predicted at 300km/h and 350km/h by fitting curve.

  • PDF

전원외란 시뮬레이터를 이용한 고속전철 이선현상 모의 실험 (The Simulation Implementation on contact loss of high speed electric railway using a Power Line Disturbance simulator)

  • 김재문;김양수;장진영;안정준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2152_2153
    • /
    • 2009
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to high-speed trains are investigated from an electrical response point of view. To analysis power line disturbance by induced contact loss phenomenon for high speed operation, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. One of the most important needs accompanied by increasing the speed of high-speed train is reduced that an arc phenomenon by loss of contact brings out EMI. In case of a high-speed train using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occurs. Throughout experiment, it is verified that an arc phenomenon is brought out for simulator operation and consequently conducted noise is flowed in electric circuit by power line disturbance.

  • PDF