• 제목/요약/키워드: Power line

검색결과 6,051건 처리시간 0.038초

전력선 모델을 위한 Line-Coupler의 설계 및 특성 (The Design and Characteristics of the Line Coupler for Power Line Modem)

  • 박종연;조계현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3132-3134
    • /
    • 1999
  • To realize the power line communication system, the line coupler is one of the most important systems, which must be adjustable to the power line characteristics. In this paper, three kinds of line couplers were designed and simulated with the Pspice, which could be useful to the power line communication systems in C-Band(95kHz-148.5kHz) frequency

  • PDF

전력전송구간을 분할하여 데이터 신호를 전송하는 전력선 통신방법 (Power Line Communication Method with Splitting of Power Transmission Interval)

  • 조재승;황일규
    • 전력전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.252-258
    • /
    • 2012
  • This paper studies the power line communication method with splitting of power transmission interval in the small DC power system using pulse width modulation. The method divides the entire interval for transmitting power and data into a power transmission interval where power is supplied to a load and a data transmission interval where power from the power supply to the load is disconnected. The circuit is designed for the implementation to separate the power line from the power supply and load. The results of tests show the feasibility of the proposed power line communication method.

가스방전관(GDT)을 적용한 서지보호장치 회로의 DC 동작전압 최적조건 고찰 (Optimization of DC Operating Voltage for GDT-Adopted SPD)

  • 최종민;전태현
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.92-98
    • /
    • 2012
  • It is made compulsory to install SPD for the purpose of protecting electric and electronic devices when an abnormal voltage such as lightning occurs to power line using power frequency of 60Hz. Recently, the high speed communication technology utilizing power line is receiving attention again as a communication technology for smart grid. The SPD influences the performances of power line communication when using SPD and power line communication system together. In order to improve the performance of power line communication, a proposed scheme for series connection of gas discharge tube to ZnO varistor was presented. This paper measured the impacts of series connection of GDT to SPD using ZnO varistor on the limit voltage of Class III SPD. This paper also presented the DC operating voltage of GDT which satisfies the limit voltage of power line communication system and SPD simultaneously.

전력선 반송통신을 이용한 전기기기 전원 제어 시스템에 관한 연구 (A Study on the Power Line Control System for Electric Machinery using Power Line Communication)

  • 김경엽;문복산;김영일;서인호;천행춘;강대기;유영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 추계학술대회 논문집(Proceeding of the KOSME 2000 Autumn Annual Meeting)
    • /
    • pp.115-122
    • /
    • 2000
  • Recently, a study on the Power Line Communication has been done by many companies and institutes due to its own merits that we can use the power line as a communication channel. But, there are serious problems about the harsh and unpredictable characteristics - noise, signal distortion and attenuation to be overcome in order that we commercialize the Power Line Communication. In this paper, we analyse the power line characteristics and apply the technology of PLC to control power of electric machinery by using ASK modulation.

  • PDF

전기철도 전원계통에서의 화재사고 사례 분석 (Analysis of Fire Accident on Power Line for DC Electric Traction Vehicles)

  • 송재용;조영진;남정우;김진표;박남규
    • 한국안전학회지
    • /
    • 제25권2호
    • /
    • pp.18-23
    • /
    • 2010
  • This paper describes a cause of fire accidents on power system fire DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accident of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it makes progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial overvoltages and/or lightning one. The deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. Finally, the power failures would be causative of the fire accident.

전력선 통신기술기반의 디지털 홈네트워크 기술 (Power-line Communication based Digital Home-Network Technology)

  • 진태석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2010년도 춘계학술대회
    • /
    • pp.992-995
    • /
    • 2010
  • 본 연구에서는 전력선 통신 기반의 IT와 통신네트워크 기술을 더하여 전력공급자와 소비자가 실시간 계속적으로 전력사용에 대한 정보를 교환함으로써 실시간 사용량과 효율적인 사용 등을 최적화 할 수 있는 차세대 성장동력이다. 전력 수요자는 실시간으로 전력 사용현황 및 불필요한 사용현황을 파악하여 불필요한 사용을 줄이고 적절한 전력분배와 흐름 통제를 조절 할 수 있다. 즉 전기요금이 가장 저렴한 시간대에 전기를 사용하고, 불필요한 사용을 줄임으로써 사용자가 능동적으로 전기를 사용할 수 있게 된다. 본 논문에서는 스마트 그리드의 기술현황과 전력선 통신에 대한 현황을 알아보도록 한다.

  • PDF

가스터빈 시송전 발전기 여자시스템에 관한 연구 (A Study of Generator Excitation System for first Power Supply to gird line)

  • 류호선;임익헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1193-1194
    • /
    • 2011
  • We performed commissioning of redundant digital excitation system for gas turbine generator. One of its issues is first power supply test to gird line when it was compared with the other commissioning. If blackout will be happened, a few of start power plants must supply power to grid line. And then generator must increase voltage and real power slowly for line charge. The trial product was installed and successfully operated at a 100MW power plant after commissioning.

  • PDF

통신 채널로써 전력선 시뮬레이터 개발 (Power Line Simulator Development for Communication Channel)

  • 박종연;정동열
    • 산업기술연구
    • /
    • 제19권
    • /
    • pp.81-89
    • /
    • 1999
  • We have developed a power line simulator which is one of the basic tools for the research of the power line communication and its control system. In the developed simulators, we have considered the transfer function of the power line, noises and signal attenuation characteristics. Simulator was made using the matlab tool program. We made the power line modern using the FSK chip(ST7537) and experimentalized to show the efficiency grade of simulator. We have expected that the developed simulators are very useful in the area for the power line communication research and the control system design.

  • PDF

전원동기를 이용한 스펙트럼 확산 전원선 통신장치의 구성 (Construction of Spread Spectrum Power Line Communication Equipment Using Power Line Synchronization)

  • 이동욱;변건식;김명기
    • 한국통신학회논문지
    • /
    • 제15권6호
    • /
    • pp.475-484
    • /
    • 1990
  • Direct Sequence 스펙트럼 확산방식에서 전원동기를 이용한 전원선 통신장치의 구성을 제안한 것이다. 전원선은 주파수대역폭이 일반적으로 10KHz~450KHz로 제한되어 있고, 특히 동기회로가 복잡해져서 제작가격이 높아지며 또한 시스템 규모가 커지며 다중통신하기가 어렵다. 동기회로를 이루기 위해서 교류전원에 동기하는 전원동기 Clock 발생회로를 제안하고 어드레스 설정기를 두어서 다중통신을 가능하게 하였다.

  • PDF

전력선 채널 특성을 통한 고속 데이터 통신 방법 연구 (Research of High data rate Power-Line Communication with Characteristics Analysis)

  • 김동순;서종완;김도경;최종찬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2499-2501
    • /
    • 2001
  • Today many researches are accomplished for power line communication. But It is very dangerous to communicate with devices using power line. Because power line is an candidate to cope with the existing communication channels. So It is need to be measured the properties of power line as communication channels, before successful communication system is possible. In this paper, we re-analysis the characteristics of power line and suggest an implementation technique for the high-data-rate power line communication modem.

  • PDF