해양 IT 소자에의 응용을 위한 RFIC/MMIC용 초소형 저임피던스 윌킨슨 전력분배기 설계 (Highly Miniaturized and Low impedance Wilkinson Power Divider on RFIC/MMIC for application to IT components of Ocean Engineering)

  • 김충열;윤영
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.412-416
    • /
    • 2005
  • In this paper we propose low-impedance and miniaturized a wilkinson power divider on MMIC passive component which was fabricated by a novel microstrip line structure employing periodically perforated ground metal (PPGM). The novel microstrip line structure showed much lower impedance and shorter guided-wavelength than conventional one. Using the novel microstrip line with periodically perforated ground metal, a miniaturized 17 ${\Omega}$ power divider was fabricated. The line width of the power divider was 20 ${\mu}m$, and the size of it was 0.110 $mm^2$, which is 21 % of conventional one. The power divider exhibited good RF performances from 10 to 20 GHz.

  • PDF

선간 단락사고에 대한 초전도 한류기의 동작특성에 대한 연구 (A study on operating properties of superconducting fault current limiter in the line-to-line fault)

  • 최효상;현옥배;김상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.86-88
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with $100{\Omega}$ of quench impedance for a line-to-line fault in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 13 kA, but with $2{\sim}3\;kA$ of DC component which decreased to zero in 6 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

765 kV 송전선로의 345 kV 운전에 따른 계통 해석 (The analysis result of temporary operation of 765 kV transmission line as 345 kV rating)

  • 우정욱;심응보;강연욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1647-1649
    • /
    • 1998
  • This paper describes the power frequency voltage and its countermeasure when a 765 kV transmission line is directly connected to a 345 kV line and operated at 345 kV voltage. The summary of this result is as follows : The western route of 765 kV transmission line doesn't need any countermeasure to reduce the power frequency voltage at the receiving end. The eastern route of 765 kV transmission needs 100 Mvar(3 phase) capacity of shunt reactor at the receiving end to reduce the power frequency voltage. The use of shunt reactors in the 765 kV transmission lines has unexpected problems, one of which is induction of high voltages on a de-energized circuit of two parallel lines. This paper examined the problem of resonance on two parallel transmission circuits in one routes.

  • PDF

대기모드 기능을 내장한 전원 장치 제어용 PWM IC 설계 (Design of PWM IC with Standby Mode Control Function for SMPS)

  • 박현일;김형우;김기현;서길수;한석붕
    • 한국전기전자재료학회논문지
    • /
    • 제21권4호
    • /
    • pp.289-295
    • /
    • 2008
  • In this paper, we designed the off-line PWM(Pulse width modulation) control IC for flyback type power converter to reduce the standby power consumption. In normal state, this off-line PWM IC generates the output pulse with $40\sim60kHz$ frequency and duty ratio of $20\sim88%$. When SMPS operates in standby mode, this IC generates the output pulse with 33kHz frequency and duty ratio of 1 %. SPICE simulation was performed to verify the standby power consumption of the power converter with designed of-line PWM IC. Power converter with designed off-line PWM IC consumes less than 0.3W when it operates in standby mode condition.

Switching Impulse Flashover Tests and Analysis for 765kV Jumper V-strings with Damaged Insulators

  • Choi, In-Hyuk;Shin, Koo-Yong;Lee, Dong-Il;Lim, Jae-Sup;Kim, Young-Hong;Lee, Hyung-Kwon
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.359-363
    • /
    • 2013
  • The 765kV transmission line will be maintained by live-line works for efficient operation. In order to maintain the 765kV transmission lines safely by live-line works, lineman has to know switching impulse flashover characteristics of the jumper V-strings with damaged insulators in advance. In order to know the flashover characteristics this paper carried out experimental flashover mockup tests for jumper V-string with damaged insulators in the outdoors. And it suggests flashover characteristics of the 765kV jumper V-strings also. The results will be used in estimating the safety of live working for 765kV transmission lines.

지중배전선로의 다회로차단기 운영방안 연구 (The Study of Multi-Circuit Breaker Coordination in the Underground Distribution Line)

  • 조남훈;하복남;이흥호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.143-151
    • /
    • 2000
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the distribution line, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. On underground distribution line, the serving of cables by earth-moving equipment is a prevalent cause of faults and the most cable faults quickly develop into bolted current. we introduce th multi-circuit breaker coordination methods in the Underground Distribution Line.

  • PDF

OFDM 방식을 이용한 전력선 통신 시스템에 관한 연구 (Power Line Application using OFDM Technique)

  • 노성호;이동욱;안도랑
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3121-3123
    • /
    • 2000
  • Power line communications is a topic which has been studied for many years, However. the technology has not been widely adopted for data networking in homes and small businesses due to low speed. low functionality. and other barriers. Recently. with a proper technology. it is shown that the power line infrastructure can also be served as a high-speed communications medium. This paper describes a transmission scheme for power lines that is based on orthogonal frequency division multiplex(OFDM) technique. This technique can be used for high-speed data communication over the power line. This paper also presents an adaptive tracking algorithm which allocate bits and power adaptively according to the channel characteristics. The performance of the proposed scheme has been demonstrated by some simulations with taking modeled channel conditions into account.

  • PDF

선대 선 전극방식의 대기압 아크억제 대책 및 Metaloxide 제거에 관한 연구 (The Study on Arc Suppression of Line-to-Line Electrodes in Air and Removal of the Metaloxide)

  • 정종한;김문환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권5호
    • /
    • pp.264-267
    • /
    • 2004
  • Recently the pulsed power systems have been widely used in many fields such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power systems, ozone generators and power sources of the laser beam. In this paper, we studied various electrical characteristics for arc suppression of line-to-line electrodes in air and removal of the metaloxide using our pulsed power system. To obtain high efficiency of the pulsed power system, we repeatedly experimented and tested their characteristics. by adjusting electrode length of the load. As a result, when the value of the electrode length and pulse repetition rate were changed at the load, the value of the arc voltage changed at the electrode load. In conclusion, we controlled arc voltage of the load by ,changing electrode length and pulse repetition rate. Also. we stydied removal area of the metaloxide using area discharge according to pulse repetition rate.

저전력 VLSI 시스템에서 MTCMOS 블록 전원 차단 시의 전원신 잡음을 줄인 파이프라인 전원 복귀 기법 (Pipelined Wake-Up Scheme to Reduce Power-Line Noise of MTCMOS Megablock Shutdown for Low-Power VLSI Systems)

  • 이성주;연규성;전치훈;장용주;조지연;위재경
    • 대한전자공학회논문지SD
    • /
    • 제41권10호
    • /
    • pp.77-83
    • /
    • 2004
  • VLSI 시스템에서 전력 소모를 줄이기 위해서는 메가블록이 동작하지 않는 동안 전원을 차단하여 누설 전류를 억제하는 방법이 효과적이다. 최근 들어 다중 문턱 전압 CMOS를 사용하여 전원을 차단하는 방법이 널리 연구되고 있으나, 동작 주파수가 증가함에 파라 전원 복귀에 필요한 시간이 짧아지게 되고, 짧은 시간에 전원이 복귀되면서 전원선에 대량의 전류가 순간적으로 흐르게 된다. 이에 따라 매우 큰 전원 잡음이 생겨서 전원 전압이 안정적이지 못하고 흔들리게 되며 이는 많은 경우 시스템의 오동작을 초래하게 된다. 본 논문에서는 이러한 문제점을 해결하기 위하여 새로운 전원 복귀 기법을 제안한다. 제안하는 기법은 메가블록의 전원이 차단되었다가 다시 복귀할 때 한꺼번에 전원을 켜는 것이 아니라 파이프라인 방식으로 몇 단계로 나누어 전원을 켬으로서 전원선에 흐르는 최대 전류 및 이에 따른 전원 잡음을 크게 억제한다. 제안하는 파이프라인 전원 복귀 기법을 검증하기 위해서 컴팩트 플래시 메모리 제어기 칩에 본 기법을 적용하여 곱셈기 블록의 전원을 차단하고 복귀할 때의 전원 잡음을 모의실험하고 분석하였다. 모의실험 결과, 제안하는 기법은 기존의 전원 차단 기법에 비해 전원 잡음을 매우크게 줄일 수 있음을 확인하였다.