• Title/Summary/Keyword: Power line

Search Result 6,054, Processing Time 0.03 seconds

Highly Miniaturized and Low impedance Wilkinson Power Divider on RFIC/MMIC for application to IT components of Ocean Engineering (해양 IT 소자에의 응용을 위한 RFIC/MMIC용 초소형 저임피던스 윌킨슨 전력분배기 설계)

  • Kim, Choong-Ryul;Yun, Young
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.412-416
    • /
    • 2005
  • In this paper we propose low-impedance and miniaturized a wilkinson power divider on MMIC passive component which was fabricated by a novel microstrip line structure employing periodically perforated ground metal (PPGM). The novel microstrip line structure showed much lower impedance and shorter guided-wavelength than conventional one. Using the novel microstrip line with periodically perforated ground metal, a miniaturized 17 ${\Omega}$ power divider was fabricated. The line width of the power divider was 20 ${\mu}m$, and the size of it was 0.110 $mm^2$, which is 21 % of conventional one. The power divider exhibited good RF performances from 10 to 20 GHz.

  • PDF

A study on operating properties of superconducting fault current limiter in the line-to-line fault (선간 단락사고에 대한 초전도 한류기의 동작특성에 대한 연구)

  • Choi, Hyo-Sang;Hyun, Ok-Bae;Kim, Sang-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.86-88
    • /
    • 1999
  • We investigated the current limiting characteristics of resistive and inductive SFCLs with $100{\Omega}$ of quench impedance for a line-to-line fault in the 154 kV transmission system. The fault simulation at the phase angles $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ showed that the resistive SFCL limited the fault current less than 15 kA without any DC component after one half cycle from the instant of the fault. On the other hand, the inductive SFCL suppressed the current below 13 kA, but with $2{\sim}3\;kA$ of DC component which decreased to zero in 6 cycles. We concluded that the inductive SFCL had higher performance in current limiting but the resistive SFCL was better from the view point of DC components.

  • PDF

The analysis result of temporary operation of 765 kV transmission line as 345 kV rating (765 kV 송전선로의 345 kV 운전에 따른 계통 해석)

  • Woo, J.W.;Shim, E.B.;Kang, Y.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1647-1649
    • /
    • 1998
  • This paper describes the power frequency voltage and its countermeasure when a 765 kV transmission line is directly connected to a 345 kV line and operated at 345 kV voltage. The summary of this result is as follows : The western route of 765 kV transmission line doesn't need any countermeasure to reduce the power frequency voltage at the receiving end. The eastern route of 765 kV transmission needs 100 Mvar(3 phase) capacity of shunt reactor at the receiving end to reduce the power frequency voltage. The use of shunt reactors in the 765 kV transmission lines has unexpected problems, one of which is induction of high voltages on a de-energized circuit of two parallel lines. This paper examined the problem of resonance on two parallel transmission circuits in one routes.

  • PDF

Design of PWM IC with Standby Mode Control Function for SMPS (대기모드 기능을 내장한 전원 장치 제어용 PWM IC 설계)

  • Park, Hyun-Il;Kim, Hyoung-Woo;Kim, Ki-Hyun;Seo, Kil-Soo;Han, Seok-Bung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.4
    • /
    • pp.289-295
    • /
    • 2008
  • In this paper, we designed the off-line PWM(Pulse width modulation) control IC for flyback type power converter to reduce the standby power consumption. In normal state, this off-line PWM IC generates the output pulse with $40\sim60kHz$ frequency and duty ratio of $20\sim88%$. When SMPS operates in standby mode, this IC generates the output pulse with 33kHz frequency and duty ratio of 1 %. SPICE simulation was performed to verify the standby power consumption of the power converter with designed of-line PWM IC. Power converter with designed off-line PWM IC consumes less than 0.3W when it operates in standby mode condition.

Switching Impulse Flashover Tests and Analysis for 765kV Jumper V-strings with Damaged Insulators

  • Choi, In-Hyuk;Shin, Koo-Yong;Lee, Dong-Il;Lim, Jae-Sup;Kim, Young-Hong;Lee, Hyung-Kwon
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.359-363
    • /
    • 2013
  • The 765kV transmission line will be maintained by live-line works for efficient operation. In order to maintain the 765kV transmission lines safely by live-line works, lineman has to know switching impulse flashover characteristics of the jumper V-strings with damaged insulators in advance. In order to know the flashover characteristics this paper carried out experimental flashover mockup tests for jumper V-string with damaged insulators in the outdoors. And it suggests flashover characteristics of the 765kV jumper V-strings also. The results will be used in estimating the safety of live working for 765kV transmission lines.

The Study of Multi-Circuit Breaker Coordination in the Underground Distribution Line (지중배전선로의 다회로차단기 운영방안 연구)

  • Jo, Nam-Hun;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.4
    • /
    • pp.143-151
    • /
    • 2000
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the distribution line, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. On underground distribution line, the serving of cables by earth-moving equipment is a prevalent cause of faults and the most cable faults quickly develop into bolted current. we introduce th multi-circuit breaker coordination methods in the Underground Distribution Line.

  • PDF

Power Line Application using OFDM Technique (OFDM 방식을 이용한 전력선 통신 시스템에 관한 연구)

  • Noh, Sung-Ho;Lee, Dong-Wook;Ahn, Do-Rang
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3121-3123
    • /
    • 2000
  • Power line communications is a topic which has been studied for many years, However. the technology has not been widely adopted for data networking in homes and small businesses due to low speed. low functionality. and other barriers. Recently. with a proper technology. it is shown that the power line infrastructure can also be served as a high-speed communications medium. This paper describes a transmission scheme for power lines that is based on orthogonal frequency division multiplex(OFDM) technique. This technique can be used for high-speed data communication over the power line. This paper also presents an adaptive tracking algorithm which allocate bits and power adaptively according to the channel characteristics. The performance of the proposed scheme has been demonstrated by some simulations with taking modeled channel conditions into account.

  • PDF

The Study on Arc Suppression of Line-to-Line Electrodes in Air and Removal of the Metaloxide (선대 선 전극방식의 대기압 아크억제 대책 및 Metaloxide 제거에 관한 연구)

  • 정종한;김문환
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.264-267
    • /
    • 2004
  • Recently the pulsed power systems have been widely used in many fields such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power systems, ozone generators and power sources of the laser beam. In this paper, we studied various electrical characteristics for arc suppression of line-to-line electrodes in air and removal of the metaloxide using our pulsed power system. To obtain high efficiency of the pulsed power system, we repeatedly experimented and tested their characteristics. by adjusting electrode length of the load. As a result, when the value of the electrode length and pulse repetition rate were changed at the load, the value of the arc voltage changed at the electrode load. In conclusion, we controlled arc voltage of the load by ,changing electrode length and pulse repetition rate. Also. we stydied removal area of the metaloxide using area discharge according to pulse repetition rate.

Pipelined Wake-Up Scheme to Reduce Power-Line Noise of MTCMOS Megablock Shutdown for Low-Power VLSI Systems (저전력 VLSI 시스템에서 MTCMOS 블록 전원 차단 시의 전원신 잡음을 줄인 파이프라인 전원 복귀 기법)

  • 이성주;연규성;전치훈;장용주;조지연;위재경
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.10
    • /
    • pp.77-83
    • /
    • 2004
  • In low-power VLSI systems, it is effective to suppress leakage current by shutting down megablocks in idle states. Recently, multi-threshold voltage CMOS (MTCMOS) is widely accepted to shutdown power supply. However, it requires short wake-up time as operating frequency increases. This causes large current surge during wake-up process, and it often leads to system malfunction due to severe Power line noise. In this paper, a novel wake-up scheme is proposed to solve this problem. It exploits pipelined wake-up strategy in several stages that reduces maximum current on the power line and its corresponding power line noise. To evaluate its efficiency, the proposed scheme was applied to a multiplier block in the Compact Flash memory controller chip. Power line noise in shutdown and wake-up process was simulated and analyzed. From the simulation results, the proposed scheme was proven to greatly reduce the power line noise compared with conventional schemes.