• Title/Summary/Keyword: Power inverter

Search Result 3,963, Processing Time 0.033 seconds

Perfonnance Evaluation of Swaged- and Extruded-type Heat Sinks Used in Inverter for Solar Power Generation (태양광 발전용 인버터 방열에 사용되는 압입형 및 압출형 히트싱크의 방열 성능 평가)

  • Kim, Jung Hyun;Lee, Gyo Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.10
    • /
    • pp.933-940
    • /
    • 2013
  • In this study, we evaluated the heat release performance of two extruded-type and two swaged-type heat sinks used in an inverter for solar power generation. The number of fins and heat transfer areas of the two swaged-type heat sinks, namely S-62 and S-98, are 62 and 98 and $2.8m^2$ and $5.3m^2$, respectively. Those for the two extruded-type heat sinks, namely, E-38 and E-47, are 38 and 47 and $1.8m^2$ and $1.9m^2$, respectively. The heat release fractions of S-62 and S-98 were measured as 82.7 % and 86.3 %, respectively. Those of E-38 and E47 were measured to be 79.6 % and 81.6 %, respectively. In this experiment, despite the mass flow rates of air entering the heat sinks being almost the same, the heat release fractions increased with heat transfer area. Furthermore, despite S-62's heat transfer area being 47.4 % higher than that of E-47, its heat release fraction was higher by only 1.3 %. We believe that this indicates the better heat transfer property of the extruded-type heat sink. S-98's heat release is only 4.4 % higher than that of S-62, but its heat transfer area is 89.3 % higher; this suggests that its heat transfer area need to be optimized.

A 12Bit 80MHz CMOS D/A Converter with active load inverter switch driver (능동부하 스위치 구동 회로를 이용한 12비트 80MHz CMOS D/A 변환기 설계)

  • Nam, Tae-Kyu;Seo, Sung-Uk;Shin, Sun-Hwa;Joo, Chan-Yang;Kim, Soo-Jae;Lee, Sang-Min;Yoon, Kwang-S.
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.38-44
    • /
    • 2007
  • This paper describes a 12 bit 80MHz CMOS D/A converter for wireless transceiver. Proposed circuit in the paper employes segmented structure which consists of four stage 3bit thermometer decoders. Proposed D/A converter is manufactured 0.35um CMOS n-well digital standard process and measurement results show a ${\pm}1.36SB/{\pm}0.62LSB$ of INL/DNL and $46pV{\cdot}s$ of glitch energy. SNR and SFDR are measured to be 58.5dB and 64.97dB @ Fs=80MHz and Fin=19MHz with a total power consumption of 99mW. Such results proved that our work has low power consumption, high linearity, low glitch and improved dynamic performance. Therefore, our work can be appled to various high speed and high performance circuits.

A Study to Improve the DC Output Waveforms of AFE Three-Phase PWM Rectifiers (AFE 방식 3상 PWM 정류기의 직류 출력파형 개선에 관한 연구)

  • Jeon, Hyeon-Min;Yoon, Kyoung-Kuk;Kim, Jong-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.6
    • /
    • pp.739-745
    • /
    • 2017
  • Many studies have been conducted to reduce environmental pollution by ships and reduce fuel consumption. As part of this effort, research on power conversion systems through DC distribution systems that link renewable energy with conventional power grids has been pursued as well. The diode rectifiers currently used include many lower harmonics in the input current of the load and distort supply voltage to lower the power quality of the whole system. This distortion of voltage waveforms causes the malfunctions of generators, load devices and inverter pole switching elements, resulting in a large number of switching losses. In this paper, a controller is presented to improve DC output waveforms, the input Power Factor and the THD of an AFE type PWM rectifier used for PLL. DC output voltage waveforms have been improved, and the input Power Factor can now be matched to the unit power factor. In addition, the THD of the input power supply has been proven by simulation to comply with the requirements of IEEE Std514-2014.

Constant DC Capacitor Voltage Control based Strategy for Active Load Balancer in Three-phase Four-wire Distribution Systems

  • Win, Tint Soe;Tanaka, Toshihiko;Hiraki, Eiji;Okamoto, Masayuki;Lee, Seong Ryong
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.176-183
    • /
    • 2014
  • Three-phase four-wire distribution systems are used for both three-phase three-wire loads and single-phase two-wire consumer appliances in South Korea, Myanmar and other countries. Unbalanced load conditions frequently occur in these distribution systems. These unbalanced load conditions cause unbalanced voltages for three-phase and single-phase loads, and increase the loss in the distribution transformer. In this paper, we propose constant DC capacitor voltage control based strategy for the active load balancer (ALB) in the three-phase four-wire distribution systems. Constant DC capacitor voltage control is always used in active power line conditioners. The proposed control strategy does not require any computation blocks of the active and reactive currents on the distribution systems. Balanced source-side currents with a unity power factor are obtained without any calculation block of the unbalanced active and reactive components on the load side. The basic principle of the constant DC capacitor voltage control based strategy for the ALB is discussed in detail and then confirmed by both digital computer simulations using PSIM software and prototype experimental model. Simulation and experimental results demonstrate that the proposed control strategy for the ALB can balance the source currents with a unity power factor in the three-phase four-wire distribution systems.

Implementation of N-screen based solar power monitoring system (태양광 발전 모니터링 시스템의 N 스크린 기반 구현)

  • Lee, Kyong-Ho;Park, Hee-Wan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.10
    • /
    • pp.151-158
    • /
    • 2014
  • In this paper, we have designed and implemented the 'N-screen based solar power monitoring system' using N-screen technology by improving the existing monitoring system that can only be accessed or controlled by PC. The HW of the system is consists of solar power modules, inverter, and relay server. And SW is implemented in consideration of the following three points. First, we applied the N-screen technology in order to support various devices. Second, we applied 1:N communication technology that multiple devices can be connected simultaneously to the relay server. Third, we also considered the security problems between server and devices. The final system has been evaluated through the operational test and received good reviews from the technical and economic point. In the future, we are expecting that this technology will replace the existing monitoring systems in various fields, like smart home, smart building, smart city, smart industry, and smart agriculture, etc.

Optimal PWM Control of Converter for Minimizing Sources Harmonic Componets (전원 고주파분을 최소화하기 위한 콘버어터의 Optimal PWM 제어)

  • 임달호;김민수;정동화
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.1 no.1
    • /
    • pp.75-82
    • /
    • 1987
  • Application of conventional phase controlled power electronic circuits causes reduced power factor and increased harmonic component in the electric sources. Therefore, an Optimal PWM strategy has been investigated here in order to reduce to a large extent these effects mentioned. Optimal PWM converter has been to minimize the rms harmonic current in the sources and has been found to have a duality with Optimal PWM inverter. The voltage patterns of Optimal PWM Inverters are governed by the same switching patterns and control laws as the current patterns for Optimal PWM converter. The improvement requires switching devices having a high speed capability. While this formerly did require thyristors with force commutation circuits, today this feature is easily implemented by using power Transistor or GTOs. The control laws for minimizing the rms harmonics current in the source, the circuits and the results are shown in the paper.

  • PDF

A Study on the Design of Controller for Speed Control of the Induction Motor in the Train Propulsion System-1 (열차추진시스템에서 유도전동기의 속도제어를 위한 제어기 설계에 대한 연구-1)

  • Lee, Jung-Ho;Kim, Min-Seok;Lee, Jong-Woo
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.2
    • /
    • pp.173-178
    • /
    • 2010
  • Electric railroad systems consist of supply system of electric power and electric locomotive. The electric locomotive is adapted to high speed driving and mass transportation due to obtaining high traction force. The electric locomotive is operated by motor blocks and traction motors. Train speed is controlled by suppling power from motor blocks to traction motors according to reference speed. Speed control of the electric locomotive is efficient by spending minimum energy between motor blocks and traction motors. Recently, induction motors have been used than DC and synchronized motors as traction motors. Speed control of induction motors are used by vector control techniques. In this paper, speed of the induction motor is controlled by using the vector control technique. Control system model is presented by using Simulink. Pulse is controlled by PI and hysteresis controller. IGBT inverter is used for real-time control and system performance is demonstrated by simulating the induction motor which has 210[kW] on the output power.

A 16kw Rotating Anode type Monoblock X-ray Generator (16kW 회전 Aonde형 모노블럭 X-선 발생장치)

  • Oh, Jun-Yong;Kim, Yuen-Chung;Kim, Hack-Seong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.97-103
    • /
    • 2006
  • This paper designs mono block type with rotating high power radiography x-ray generator and studies 16kW X-ray generator possible to adapt hospital mobile radiography and industrial X-ray equipment and design. This equipment uses rotating anode type x-ray tube at high voltage generator to generate x-ray and adds rotor operating circuit to operate rotor of x-ray tube. The size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of x-ray tube voltage and tube current correspond to variable load.

Hormonic Evaluation of An Imported IAT(Intra Airport Transit) System in Incheon International Airport (인천 국제공항청사 경전철 도입에 따른 고조파 영향 분석)

  • Kim, Jin-O;Song, Hak-Seon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.41-47
    • /
    • 2006
  • This paper presents harmonic evaluation of an IAT(Intra Airport Transit) system in Incheon International Airport. It will be used for electric vehicles with 80[kW] per car produced by Mitsubishi Heavy Industries Ltd, and which is constructed with SIV(Static Inverter), VVVF controller and two induction motor. The vehicles operated in the IAT system can be treated as rapidly changing DC loat and at a feeding substation, 3-phase electric power is transferred to DC 750[V] by rectifier. Since vehicles are changing continuously, the voltages for the load fluctuate in the IAT system, and moreover, the voltage fluctuation generates high-order harmonics. It results the difficulty in maintaining power quality in KEPCO systems' side. The power quality of the IAT system in Incheon International Airport is evaluated using PSCAD/EMTDC simulator in the paper. The THD(Total Harmonic Distortion) of voltages and TDD(Total Demand Distortion) of currents, indices are calculated for the IAT system using the results of PSCAD/EMTDC dynamic simulation.

Advanced Synchronous Reference Frame Controller for three-Phase UPS Powering Unbalanced and Nonlinear Loads (3상 무정전 전원장치에 적합한 새로운 구조의 동기좌표계 전압제어기)

  • Hyun Dong-Seok;Kim Kyung-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.508-517
    • /
    • 2005
  • This paper describes a high performance voltage controller for 3-phase 4-wire UPS (Uninterruptible Power Supply) system, and proposes a new scheme of synchronous reference frame controller in order to compensate for the voltage distortions due to unbalanced and nonlinear loads. Proposed scheme can eliminate the negative sequence voltage component due to unbalanced loads and also reduce the harmonic voltage component due to non-linear loads, even when the bandwidth of voltage control loop is a very low. In order to compensate for the effects of unbalanced loads, the synchronous reference frame controller with the positive and negative sequence computation block is proposed, and the synchronous frame controller with a bandpass filter is proposed to compensate for the selected harmonic frequency of output voltage. The effectiveness of the proposed scheme has been investigated and verified through computer simulations and experiments by a 30kVA UPS.