• Title/Summary/Keyword: Power feedforward

Search Result 248, Processing Time 0.035 seconds

Two-stage & Single-stage Power Factor Correction circuits for Single-phase Power source (단상전원에 적합한 단일단 및 2단 역률개선회로)

  • Kim Chert-Jin;Yoo Byeong-Kyu;Kim Choong-Sik;Kim Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1214-1216
    • /
    • 2004
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic contents. Typically, these SMPS have a power factor lower than 0,65. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. PFC circuit have tendency to be applied in new power supply designs. The input active power factor correction circuits can be implemented using either the two-stage or the single-stage approach. In this paper, the comparative analysis of power factor correction circuit using feedforward control with average current mode single-stage flyback method converter and two-stage converter which is combination of boost and flyback converter. The two prototypes of 50W were designed and tested a laboratory experimental. Also, the comparative analysis is confirmed by simulation and experimental results.

  • PDF

Comparative Analysis of Single stage Power Factor Correction Circuit (단상 전원에 적용되는 수동 및 능동 역률개선회로의 특성)

  • Kim, Cherl-Jin;Kim, Choong-Sik;Yoo, Byeong-Kyu;Yoon, Shin-Yong;Baek, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.166-168
    • /
    • 2004
  • Conventional Switched Mode Power Supplies(SMPS) with diode-capacitor rectifier have distorted input current waveform with high harmonic order contents. Typically, these SMPS have a power factor lower than 0,7. To improve with this problem the power factor correction(PFC) circuit of power supplies has to be introduced. Specially, to the reduce size and manufacture cost of power conversion device, the single-stage PFC converter is increased to demand as necessary of study. In this paper, comparative analysis of Valley-fill, boost and feedforward type single stage power factor correction circuit based on the flyback converter is given. Also, the validity of designed three type of single stage PFC circuit are confirmed by simulation and experimental results.

  • PDF

Supplementary Control of Conventional Coordinated Control for 1000 MW Ultra-supercritical Thermal Power Plant using Dynamic Matrix Control

  • Lee, Youngjun;Yoo, Euiyeon;Lee, Taehyun;Moon, Un-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.97-104
    • /
    • 2018
  • This paper proposes supplementary control of conventional coordinated control of a power plant which directly affects network frequency. The supplementary control with dynamic matrix control is applied for 1000 MW power plant with ultra-supercritical (USC) once-through boiler. The supplementary control signal is added to the boiler feedforward signal in the existing coordinated control logic. Therefore, it is a very practical structure that can maintain the existing multi-loop control system. This supplementary controller uses the step response model for the power plant system, and on-line optimization is performed at every sampling step. The simulation results demonstrate the effectiveness of the proposed supplementary control in a wide operating range of a practical 1000 MW USC power plant simulator. These results can contribute the stable operation of power system frequency.

Control Strategy of Resonant DC Link Inverter for UPS (UPS용 병렬공진형 직류링크인버터를 위한 제어방식에 관한 연구)

  • Beak, J.W.;Yoo, D.W.;Min, B.G.;Ryu, S.P.
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.159-161
    • /
    • 1994
  • A new control technique which generates high-quality sinusoidal output voltage from a single-phase resonant do link inverter suitable for the UPS systems is presented. The inverter output voltage control system has the PID controller with a minor loop of the filter inductor current and tile feedforward controller. The proposed control scheme also solves resonant voltage overshoot without any additional switch or passive component, resulting in pulses with uniform amplitude and high efficiency. Experimental results in the case of linear and nonlinear loads are presented to confirm the usefulness of the Proposed control algorithms.

  • PDF

Bidirectional High-Frequency Link Inverter with Deadbeat Control

  • Salam, Zainal
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.726-735
    • /
    • 2009
  • This paper presents a Bidirectional High-Frequency Link (BHFL) inverter that utilizes the Deadbeat controller. The main features of this topology are the reduced size of the inverter and fewer power switches. On the secondary side of the transformer, the active rectifier employs only two power switches, thus reducing switching losses. Using this configuration, the inverter is capable of carrying a bidirectional power flow. The inverter is controlled by a Deadbeat controller, which consists of the inner current loop, outer voltage loop and a feedforward controller. Additional disturbance decoupling networks are employed to improve the system's robustness towards load variations. A 1-kVA prototype inverter has been constructed and the Deadbeat control algorithm is experimentally verified. The experimental results show that the inverter has high efficiency (91%) with low steady state output voltage total harmonics distortion (1.5%).

Controller Design and By-Pass Structure for the Two-Stage Grid-Connected Photovoltaic Power Conditioning System

  • Lee, Seong-Jun;Bae, Hyun-Su;Cho, B.H.
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.206-208
    • /
    • 2009
  • In this paper, a systematical controller design method for a twostage grid-connected photovoltaic power conditioning system is proposed. For a pre-stage boost converter to achieve the stable operation in the entire region of solar array, the digital resistive current mode controller is used. This algorithm is very simple to implement with a digital controller and there is no power stage parameter dependency in the controller design. For a post-stage single-phase full-bridge inverter, a PI controller with a feedforward compensation for the inner current control is employed. Furthermore, in case that the operating point of the solar array under varying environmental conditions is higher than the required voltage for the inverter current control, the bypass mode for the boost converter is possible for the more efficient operation. The proposed control scheme is validated through the experiment of the prototype two-stage power conditioning system hardware with a 200W solar array.

  • PDF

The Steam Temperature Control of Renovated Boiler in 100MW Power Plant (100MW 발전소 개조 보일러의 증기온도 제어)

  • Lim, Geon-Pyo;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1935-1940
    • /
    • 2011
  • The control logic of steam temperature was redesigned, tested and applied to the power plant after its steam temperature equipments had been revised. This power plant use the ancillary gas gotten in the process of making iron in the steel mill. The boiler of power plant has the superheater and reheater to make the superheated steam. The superheater and reheater have the spray valve to control their temperature. The reheater has the gas bypass damper additionally in this plant. The control logics were redesigned in cascade forms and the initial parameters of control logics were calculated from the several step tests. The final parameters could be obtained through the several repeated tests and the feedforward functions were added by temperature deviation and air flow. The power plant is being commercially-operated normally by improved control logics and It is expected that this improved controls help the efficiency improvement and safe operation of plant.

A Study on Turbine Control and Turbine Bypass Control during Startup of Thermal Power Plants (화력발전소 기동시 터빈 바이패스 시스템과 터빈 제어에 관한 고찰)

  • Choi, In-Kyu;Park, Doo-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1664_1665
    • /
    • 2009
  • Many years ago, most of thermal power plants built in this country were of subcritical pressure, of medium or small size, of constant pressure operations and of drum type steam generators with circulation type boilers. But, nowadays almost all of them were of high efficiency, of supercritical pressure, of big capacity, of sliding pressure operations, and of once through type steam generator. It has such advantage as the reduction of startup duration, but it control system and operation method are very complicated. It has a big difference in operation method of turbine and boiler. The feedforward control needs to be introduced to prevent such problems as thermal shock during the transit from normal operation into bypass operation. This paper introduces the turbine control and turbine bypass control during startup of thermal power plants.

  • PDF

A Design of Improved Digital Controller of BLDC Motor Using DSP (DSP를 사용한 브러시리스 DC 모터의 향상된 디지털 전류제어기 설계)

  • Ha, Young-Suk;Ahn, Ho-Kyun;Park, Seung-Kyu;Lee, Jong-Ju;Kim, Sung-Hwon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1209-1211
    • /
    • 2001
  • Generally, the current controller is located inner the whole controller, so the characteristic of the current controller is important in controlling performance of the upper controller. A current control loop in motor control is designed so that it is 10 times faster than the speed control loop of the upper controller. Thus, the current controller with complex control algorithm is not proper. In this paper, the improved current controller using a conventional digital PI controller and feedforward controller for the brushless BC motor is designed.

  • PDF

A Study on the Design of Power Amplifier for the Repeater using Code Division Multiple Access (CDMA방식 중계기용 전력증폭기의 설계에 관한 연구)

  • Kim, Han-Suk;Kim, Hoon-Yong;Kim, Dae-Jyung;Lee, Jong-Arc
    • Journal of IKEEE
    • /
    • v.3 no.2 s.5
    • /
    • pp.268-275
    • /
    • 1999
  • In this paper, a new type of linearization technique proposed, in which the predistortor was added to the feedforward linearizer. As the input power level is applied to HPA, the gain and phase characteristics of the amplifier are also varied. By using of the predistorter the amplitude imbalance and phase imbalance is kept constant. Experimental results are present for Korea PCS frequency band. The center frequency of the feedforward amplifier is 1.843.75 MHz with 1.23 MHz bandwidth. The 2-tone intermodulation distortion at 37dBm output power is about -50dBc, and spurious emission are -46dBc at $fc{\pm}\;885KHz\;and\;-52dBc\;at\;fc\;{\pm}1.98MHz$, respectively.

  • PDF